HomeMy WebLinkAboutAgenda_Workshop_07/08/1969i ME~MOR4NDLIl~1
FROM ~ Villa.ge Manager
TO ~ Each Village Councilman
~~ July 2, 1969
S~~'~T ~ Workshop Meeting, Tuesday, July 8, 1969
?:30 P.M. Vi1la,ge Hall
There will be a Workshop Meeting tomorrow night as mentioned above to
discuss:
(1) Police (fief Dusenberry will present Police Department Proposals
as requested.
(2) Councilman Cunningham twill discuss Installation of a larger
sign Drain Pipe across Country Club-Drive from the Country
Club to the Canal.
bert Harp
RH:sw
M E M O R A N D U M
From Vill,a,ge Manager
To Each Councilman and Building Inspector
Subject: Plumbing Inspection - Varnadore Apartments
Date July 11, 1969
Pursuant to our discussion at Tuesday nights Workshop Meeting,
the Building Inspector and myself went to the apartments and looked at.the
plumbing in question. We found that the main sewer line r~mning under the
entire building was 4" cast iron pipe and is to be connected to the Pla,ntreat
Sewerage System. Vents taking care of the first and second floor toilets
~y~ere of 4" size. and 2" size, with one 311 vent through the roof. Vents for
sinks 1~Tere of 2" size a 11 the way through the roof. The Plumbing Code allows
a maximum of 22 fixtures for the 4" vent and this construction has only 18
fixtures. This type plumbing construction conforms to the Plumbing Code.
The Village Manager was subsequently advised that some of the vents
were only 3" size and this could be determined since they were in 2rr g q,r,
partitions. Another inspection by the Village Manager and Building,Inspeetor
found six (6) 3" pipes located on the first floor and the Building Inspector
advised that these were support columns as provided for on the glans, not
vents. There was two (2) of these support columns in Apartment No. I,
two (2) in Apartment No. 5, and two (2) in Apartment No. 9.
The plans for the construction were prepared by Charles E. Toth,
AIA, Architect, 1279 East Atlantic Avenue,- Delray Beach, Florida, State of
Florida Registered -Architect No. 2103, and the plans carry his seal and
signature. The plans were also approved ~ the Florida Hotel and Restaurant
Coumussion for which they issued their permit No. B 4294, April 16, 1969;.
Enclosed is a copy of the Plumbing Riser Diagram taken from the
plans .
Based upon the on site inspection of the project and inspection of
the approved pans for the construction, it appears that the construction meets
or exceeds the requirements of the Plumbing Code.,