Loading...
HomeMy WebLinkAboutDocumentation_Planning and Zoning_Tab 03_02/21/2019VILLAGE OF TEQUESTA DEPARTMENT OF COMMUNITY DEVELOPMENT Staff Report —Planning & Zoning Board Meeting — February 21, 2019 ETITION: SPM 02-19 Site Plan Modification )CATION: 250 Tequesta Drive Tequesta, FL 33469 OWNER: TEQUESTA BUSINESS ASSOC 250 Tequesta Drive Tequesta, FL 33469 APPLICANT: John Isleib P.O Box 1397 Jupiter, FL 33468 REQUEST: Application from TEQUESTA BUSINESS ASSOC for a Site Plan Modification to install an approximately 8 ft. by 13 ft. aluminum canopy over an existing sidewalk. The application also includes an approximately 8 ft. by 25 ft. tan canvas awning. The proposed structures will be located on the west building elevation facing Old Dixie Highway. The address of the property is 250 Tequesta Drive 101, Tequesta, Florida 33469. Subiect Application Tequesta Corporate Center 250 Tequesta Drive Tequesta, FL 33469 1.....................iiw LOCATION MAP - ridge Rd ram`. 1 Department of Community Development —Staff Report—Tequesta Corporate Center— SPM 02-19 II. LAND USE AND ZONING EXISTING LAND USE FUTURE LAND USE ZONING SUBJECT PROPERTY Mixed Use Mixed Use MU -Mixed Use Tequesta Corporate Center North Mixed Use Mixed Use MU -Mixed Use Tequesta Trace South C-3 (General Commercial Lo Presti Plaza LLC Commercial (C) Commercial (C) District) EAST Mixed Use Mixed Use MU Mixed Use Paradise Park West C-2 (Community Renu Medical Commercial (C) Commercial (C) Commercial District) III. BACKGROUND The Tequesta Corporate Center is an existing three-story building located on the corner of Tequesta Drive and Old Dixie Highway. The existing building was built in 1985. IV. STAFF ANALYSIS The subject application is for a minor site plan modification to install an approximately 8 ft. by 13 ft. aluminum canopy over an existing sidewalk. The application also includes an approximately 8 ft. by 25 ft. tan canvas awning. The existing lot coverage calculation is 8,605 sq. ft. (18.2%). The subject application increases the existing lot coverage calculation by 305 sq. ft. The proposed lot coverage calculation is 8,910 sq. ft. (18.9%). Per code section 78-180 (m) (4) lot coverage requirement is max 62%. The proposed site plan modification is in compliance with code. The subject application does not modify the height and footprint of the existing building. V. FINAL REMARKS This development application met the requirements set on Section 78-334 notice of hearing. The notice of hearing was advertised on February 11, 2019. 2 1 Department of Community Development —Staff Report—Tequesta Corporate Center —SPM 02-19 EXISTING SITE CONDITIONS 0 1 � lr e a •T s C ,:. 250 Tequesta Drive Site Map 3 Department of Community Development — Staff Report—Tequesta Corporate Center —SPM 02-19 -------------- 4 ' DEPARTMENTAL USE ONLY i ' Ck. # , Fee: , , ' Date: , , PROJECT q: ' -----------------------� APPLICATION FOR MINOR SITE PLAN REVIEW PLANNING & ZONING BOARD Meeting Date: VILLAGE COUNCIL Meeting Date: INSTRUCTIONS TO APPLICANTS: 1. Please complete all sections of this application. If not applicable, indicate with N/A. 2. Provide all required documents as shown on the attached checklist. If not applicable Indicate with N/A. All construction, additions, and/or alterations within the Village, except in districts R-1A and R-1, must be reviewed by the Planning & Zoning Board. The Planning & Zoning Board meets the third Thursday of every month at 530 p.m., as needed in the Village Nall Council Chambers, 345 Tequesto Drive. The applicant will be informed by letter of their scheduled meeting date. The Planning and Zoning Board shall have general authority as outlined in Sec. 22.53. 1. PROJECT DESCRIPTION AND OWNER & AGENT INFORMATION PROJECT NAME: k 42 1 a L PROJECT ADDRESS: �` 5 e- DESCRIPTION OF WORK/MODIFICATION: S ��•���� o�� ���C�.n C' kis-uWr cy, r :6;�as 0'-J<-' Q "SvA 4. Property size in acres and square feet: ° 3 0. e- `A 7 S "i "e 'r- -r* e e� Estimated project cost: 1 5 O Property Owner(s) of Record: Address: �S0-C•zy�aes.,, mac. S.,'.�� 3,0 \ �gve 5�'�. i�(.. 33y Phone No.: SG � - -74-7 -301 i Fax No.: S C" I -_Ny - 3C" ! E-mail Address: t'�)' R Applicant/Agent (if other than owner complete consent section on next page): Name: Address: ISO � cy �9 e S 'k-k% 4'6c , ��` � � � afJ � —i e O u e S� �. � F �., � _�l LA � Phone No.:SO k- 74 7-3°'R ( Fax No.: SG I -14 y -3G s E-mail Address: ^\n�"^" 1 II. LAND USE & ZONING A) ZONING DESIGNATION M, x -A 1 s e B) FUTURE LAND USE DESIGNATION tj' (\ C) Existing Uses) M u D) Proposed Use(s), as applicable N{ l\ Ill. OWNER/APPLICANT ACKNOWLEDGEMENT AND CONSENT Consent statement (to be completed if owner is using an agent) I/we, the owners, hereby give consent to 7Sot, •-, MS k i ,\- to act on my/our behalf to submit this application, all required material and documents, and attend and represent me/us at all meetings and public hearings pertaining to the application and property I/we own described in the application. By signing this document, I/we affirm that I/we understand and will comply with the provisions and regulations of the Village of Tequesta, Florida Code of Ordinances. I/we further certify that all of the information contained in this application and all the documentation submitted is true to the best of my/our knowledge. Ow r Name (please print) V ner's Signature l/eljln► Date Applicant/Agent's Name (please print) Applicant/Agent's Signature/!AJ�gent's Signature % /<) t 19 Date IV. APPLICATION FEES (1) Review by the Planning and Zoning Board. The Community Development Director or designee shall submit such application for Planning and Zoning Board review within 45 days of receipt of a completed application. Fee: A) $300.00 (final approval) OR B) $500.00 (recommendation to Village Council) (2) Review by Village Council. Within 45 days of review by the Planning and Zoning Board, the Community Development Director or designee shall then submit such application, including the recommendations of the Planning and Zoning Board, for Village Council review. Fee: a $300.00 fee plus an additional fee based on the estimated cost of work applies. To cover all additional administrative costs, actual or anticipated, including, but not limited to, engineering fees, consultant fees and special studies, the applicant shall compensate the village for all such costs prior to the processing of the application or not later than 30 days after final application approval whichever is determined as appropriate by the village. Failure to make such payment may be grounds for not issuing a building or zoning permit, certificate of occupancy or completion. Costs associated with advertising for public hearings and other public notice requirements are the responsibility of the applicant. The fee shall be paid prior to h application being sche uled for a pu is hearing requiring notice. /P// Owner's Signature to Acknowledge Lance Lilly From: John Isleib <johnisleib@comcast.net> Sent: Tuesday, January 29, 2019 1:02 PM To: Lance Lilly Subject: Tequesta Business Associates site plan modification Lance, Pursuant to your request, please find the following detailed descriptive narrative for the minor site plan modification at 250 Tequesta Dr, Tequesta FL 33469: Installation of approximately 8' X 13' aluminum canopy (104 sq ft) over existing sidewalk at west entrance facing Old Dixie Highway and continuing west over existing sidewalk with an approximately 8' tapering to 7' X 25' ( 200 sq ft) brown canvas awning. Sent from my iPad TEQUESTA BUSINESS ASSOCIATES P.O. BOX 1397 JUPITER, FL 33468-1397 PHONE (561)747-3091 FAX(561)744-3665 January 29, 2019 Mr. Lance Lilly, Dept of Community Development Village of Tequesta 345 Tequesta Dr Tequesta,FL 33469 Ililly@tequesta.org Re: Awning/canopy installation 250 Tequesta Dr Tequesta, FL 33469 Dear Mr. Lilly, This letter is to serve as authorization for John Isleib to serve as agent regarding all matters on behalf of Tequesta Business Associates in the process of application for site plan modification. Respectfully, b/� J Louis N. Feibel Owner/partner State of Florida, Palm Beach County On the 29th day of January, 2019, before me a notary public, Louis N. Feibel personally appeared and is personally known to me to be person subscribed to within this document, and acknowledge that he executed the same for the purpose therein contained. r In witness hereof, I here unto set my hand and official seal. My commission Expires: E*olo-- y, Notary Public State of rlon`i John J Weib8My Commission GG 196322 Expires03l26/2022 FASTEN FRAME TO EXIST. WALL WR'e X4' S.S. SLEEVE ANCHORS THRU MEMBER O'XB•X3's' BASE PLATE WELDED TO COLUMN WN' FILLET WELD - FASTEN TO FOOTING W1(4) 9'e X4' S.S. WEDGE ANCHORS EXISTING BUILDING OUTSIDE CORNERS 24.0 X 24• DEEP UNREINFORCED FOOTING Fc'=3000 PSI (TYPICAL) FASTEN FRAME TO EXIST. WALL WPr'i X4' S.S. SLEEVE ANCHORS THRU MEMBER GENERAL NOTES: 1. NI pipe shall be ASA Schedule 40 steel, galvanized. 2. All oltw metodal shall be A36 steel (U.O.N.). 3. All welds shall comply with A.W.S. code (latest efton). 4. Cover all welds with corrosion resistant coallrg. 5. AN structures designed in accordance with Sedan 31 and Section 18 (InchrAng Section 1607.1 - 5 psf He bed) of the Florida Building Code (Bch Edbon) - ASCE 7-10. 8. Awning covers shall be removed In periods of high Winds; spedllcepy winds in excess of 75 m.p.h. 7. Awning wkover will sustain 105 m.ph. (3 second gust) - Risk rmtegay II, Exposure D. 8. Frames without fabric will sustain 100 m.p.h. winds (3 seoand gust), Exposure D. 9. All connections shall be hay welded (U.O.N.). 10. Provide W* on &m*V to Indmcate coves removal when winds exceed or are predicted W exceed 75 m.p.h. ALL RAFTERS AND HORIZONTAL MEMBERS SHALL BE 1'0 PIPE (U.O.N.) ALL VERTICAL MEMBERS SHALL BE %'0 PIPE (U.O.N. ALL SPACES EQUAL (U.O.N) AWNING Leonard A A. .,> rrecTW�Y�AM Tyl ka .1 r. PFiLLS BY LEW A TYl/U t r1a sons P.R. warp A DIDTTAL TAL 5mO1NTTaRE 2 tr1 ,k �d AOC/.P DATE.-*MDE6OF 2019.01 • 1 TIMOOCUYENT ARE NOT �� asses► / �TW WON�WIE r�T� h ?M ON ANY ELECTRKX. aaWWll �Ee. 07:35:49 -05'00' FL. LIc. NP. 811le aaTE: �ro DRAatI JR CIrECi3:D1 LT OF 2 EXISTING BL1kDING OUTSIDE CORNER r W-W FASTEN FASCWGUTTER TO WALL W/ WX4' S.S. SLEEVE ANCHORS 0 24.OJC (3 SIDES) 13'4r EXISTING BOLDING INSIDE CORNERS W-0" 3'EMS FASCUVGUTTER 0.012W WALL (M.4 SIDES) PROVIDE CANOPY DRAINAGE THRU BOTTOM OF FASCIA GUTTER TO DOWNSPOUT CANOPY ISOMETRIC t 3• X e' SELF MATING PAN (010W WALL.) ANCHORED TO LIP OF GUTTER W/(2) 014 X V S.S. SELF TAPING SCREW (FRONT i WOO CANOPY SIDE ELEVATION 3' X W SELF MATING PAN (0.OW WALL) ANCHORED TO LIP OF GUTTER Wl (2) N14 X V S.B. SELF TAPING SCREW (FRONT & BACK) 4• X£ FASCWGUTTER (0.125' WALL) FASTEN FASCNKMTER TO WALL WI VX4• S.S. SLEEVE ANCHORS 0 24.OiC (3 SIDES) 2.Oir 3.000' 8o 3' v W SELF MATING PAN (0.0SS WALL • 8083•TO ALUMINUM) ANCHORED TO LP OF GUTTER FASCA WITH ONE (2)#14 X r S.B. SELF TAPPING SCREW (FRONT & BACK) 1. ALL MATERIALS SHALL BE 00 3-TO ALUMINUM (U.ON.) 2. ALL CONNECTIONS SHALL BE FULLY WELDED (U.O.N.) 3. ALL WELDS SHALL COMPLY WITH AW.S. CODE (LATEST EDITION) 4. COVER ALL WELDS WITH CORROSION RESISTANT COATING. S. VERIFY ALL DOMWSIONS IN FIELD. CODE ANALYSIS: ASCE 7•10 V= 170 MPH (9 SEC. GUST) RISK CATEGORY II EXPOSURE PARTIALLY ENCLOSED STRUCTURE COMPONENT AND CLADDING PRESSURE • 4 5 PSF MAIN CODES ONCLUDINO LOCAL AMENDMENTS) �N FLORIDA BUILDING CODE I ASCE 7.10 STH EDITION FLORIDA FIRE PREVENTION CODE COMPONENTS AS MANUFACTURED BY EASTERN METAL SUPPLY 0' (0.t26 RALUMINUM) CANOPY Leonard A A � �rJO 11 IIA„� na rtalHA.>er� 1ULMlyL mN� 4fA1m. A.01YA0ATLMA-, Tylka Jr. lt! it G '�'.. AtAO�pAN11R.000NFl01 0 2019.01.21 07:36:46-05'00' LERLYD A TTLU X }i I'L LIC. NO. 3113E Iti E DATE: S715/IE SCALE. N1T$ DRNUL JR CG*iCKED: LT JC5 Nos %3240D SHUT O7 2 SIEE' t ' j 89=$° Ff 4 Approx. 8' by 13' Alum. Canopy (104 sq. ft) `t at West Entry facing Old Dixie Hwy w J r Approx. 8' by 25' Tan Canvas Awning (200+/- sq. ft) at West Entry over existing sidewalk facing Old Dixie Hwy Approx. location of typical four (4) concrete i underground foundation posts. Awning posts/columns will be galvanized steel and color �. will not be changed. ;o:P L­4& G-,,t5noc, 5C—n_j.,& DvR--rz, 14.4. Cpsia,-n�J ------ ------ ME W_vj KAN 0 P4.14, R .2c ­lk x�c p AN71 laaro "M) IMM OF cr�Avftmoe r.,\T4• -k- -) 0 \,j % I Y. ca.Df SAO q#.o 1xio. 7 ` -�`\ "•_ ter.. _, - I ;;` \,: S E T I: A 'I 51 0_1 Q. Tfj4z wv, CV— c (A G v r— *,t o POO � S Rom\ �V 40— companies ;Hasco 840 U.S. ONE- SUITE 400 627-1300 -MING AND DRAINAGE FLAN : NwIth Palm Booch,Fforida 33406 41 SCALE 1"= 'C' -rEQUESTA CORPORATE CENTER' ioz 7. TEOIJESTA DRIVE AND OLD DIXIE HIGHWAY T EQUESTA, FLORIDA 33458 Loa%akhm Rim E fmm"Ul DGMIM DiOdcl K2- 3 R! -A G L FE, P. VEEBE FINAL PLAN APPROVAL � �ji INEER if-4- T c Al x No wilm IQ= RvWvi, FL OR I V A A C H, FLORDAL s I I E 11 A T A Tctl Area lFrom Survey; 47,1'0 Scliare Feet = 1.083 ACTC- il"F T TMAL PR,)jf.,-T fizifl Total Lot CoYeragt, (Structure; 7 Ivy Total Lot Coverage (I-T.Sur"ace) 41 :!5O 41 850 ss /.I� T Tote: Lot Cove'rage {Green fi.Teaj� -3 OP AN . ... .. . 4 Cmn d V Q sw 4, &4 Do, WAY ARF;CWVS 14) J_j —4TOP FOR. PEDESTRiANS IN N ROS, C WE) ALW'nVERHEASSIGN9 SEE LANDSCAPE 41 T". PAiNTF NOTES\,SHEET 2 05h, 0 i WATCii For, CARS ATSWALK WEIXIi. EN, SE I b FRONT ELEVATION (TEQUESTA DRIVE) A s, H A§kopplm &llr^=,� d fVtER SECOND FLOOR DRIVE IN TELLERS �O _J a X z AZI f (4 FOES AS Sure loop t. T DUMPSTE" % `fo Al s TAtR IN PHASE Ir LIRE OF PHASE n A' 8OVE -4� �!STOP PARKING FOR 69 CARS LOAM" SPACE 1 T E PLAN BRIDGE ROAD 06RY ar HaSCO CollipallieS TIEQUESTA CORPORATE CENTS 8iS US mCw"V 004E - SWTE 1 627-1300 Naft Pam asuchfkWids 33400 2 - 4 85 D- WIL,LiAM 8Ef9f_ HASCO COMPANIES A R C H I T E C T NOtT% ?A m LM MACK MOM& O3