Loading...
HomeMy WebLinkAboutDocumentation_Regular_Tab 10A2_4/14/1988 34.19 Thomas G. Bradford , Village Manager Village of Tequesta, Florida Mr Bradford The Division of E.M .S . has ordered the ANI/ALI 9-1-1 equipment for our police department per our request and expect to have it ready to install by June 1st of this year . The $40 ,000 worth of equipment plus $10,590 worth of yearly maintenance is being paid by the Division of E .M .S . , however there are special requirements for the installation of this equipment that we must cover. The equipment requires a dedicated electrical line served from a 230V, 60Hz , single phase 60 AMP service . It also requires private lines- for the phone service itself . This means that that we have to install this utility at Village expense and will require a two foot trench dug from the rear of the police station to the rear of the garage area where the electric meter and the phone junction box rooms are located . I recommend we lay three or four conduits at that time (only two will be used at this point , one for phone, one for electric) and the other spares for future use . The equipment itself will be installed against the west wall of the dispatch area between the captains office and main hallway. Due to the already cramped working conditions , this is the only space available. The equipment will have to be safe guarded from damage by building some sort of partition around it . The location is close to the jail cell hallway where rowdy prisoners are brought back and forth to the squad room, fingerprint area and any scuffle might cause damage to the delicate machines To operate the equipment , Southern Bell engineers advised that the service should be connected to a emergency electrical source to keep the 9-1-1 system going during sure times of emergency such as hurricanes, etc . where power is usually knocked out . This is going to be problem because the emergency generator that we now use is only a 30 amp service and is almost at full capacity now when in use. We have four routes to go, one is to install .a new, higher amperage generator to cover all the power needs, or two install . a new second generator just to cover the 9-1-1 equipment , or three, hook the -9-1-1 system up to the old generator and hope for the best , or four, hook the system up direct which would loose 9-1-1 capabilities during a power failure. g 8 ;1 l 1 This is the work that must be completed by the Village prior to June 1st when we are scheduled to have the ANI/ALI 9-1-1 equipment installed. The cost (per Conner Electric Co.) for running the necessary conduit and wires plus the switch boxes and plugs , etc . will be as follows : Price of 2" conduit run @ $93.00 ea . from the rear of the garage area to the base of the police department building . We need two runs and should install an extra while the ditch is open . TOTAL = $279.00 Price for cutting the driveway from the P.D. building to the front of garage. TOTAL = $310.00 Price for digging ditch from P.D. building to rear of garage after driveway is cut . (this could be eliminated if the maintenance dept dug the ditch) . TOTAL = $460.00 Price for wire , switch boxes etc . and installation . TOTAL = $1440.00 Total for Conner Elec . Co. to do work is $2489.00 Total if we dig ditch and they install is $2029.00 r • Mr J. Humpage of Conner Electric has checked into the prices of generators to suit our up coming needs. The following prices are straight retail and he advises we could count on a 15 to 20 % discount . Generator brand is Onan A 100 amp , 30,000 watt unit costs retail = $12,500 . A 65 amp , 18 ,000 watt unit costs retail = $9 ,000. Muffler kit for 100 amp unit is extra = $350. Electrical transfer switching box (100 amp unit = $3,600.) ( 65 amp unit = $2,600.) Installation of generator, wiring of switch box and electric hookups = $3,700. Optional enunciator (desk area readout of generator gages = $440. TOTAL COST : 100 amp unit = $20,150. (plus $2,489. conduit section) = $22,639. 65 amp unit = $15,300. (plus $2,489. conduit section) = $17,789. Southern Bel Network Marketing Drawer X West Palm Beach, Florida 33402 2-24-88 Captain C. Roderick Village of Tequesta Police Dept. 357 Tequesta Drive Tequesta, Fla. 33469 Dear Captain Roderick, This letter is confirmation of our meeting scheduled for Wednesday, March 2, at 1145 A.M. to be held in your offices at the above address. The purpose of this meeting is to discuss and establish equipment room requirements for your new E9-1-1 system being installed in June, 1988. I have attached typical E9-1-1 equipment room specifications to give you a preliminary idea of what will be required. Ms. Jackie Ferguson and/or Bill Walter, Bic. Eng's. as well as Bob Schoneman, SSIM Foreman will be accompanying me on this contact. If you have questions prior to our meeting please contact me at 837-9292. Sincerely, m Bastian Systems Designer So. Bell Mktg. CC: Jack Smith Bob Schoneman Jackie Ferguson Bill Walter T. W. (Bill) Walter Building Industry Consultant Southern Bell A BELL SOUTH Company 3300 Okeechobee Rd.,Room 237 Fort Pierce, Florida 33450 (305) 286-2622 A BELLSOUTH Company SHEET 2 • ITEMS TO BE PROVIDED BY CUSTOMER 1. :: Power service panel, served from 230v, 60Hz, single phase -60 Amp service equipped with circuit breakers as specified on sheet 3. See sheet 3 for detail. This shall be dedicated telephone company branch with no other equipment connected to it. la. Two copper ground bars are to be attached to the Power Service Panel. See sheet 3 for details and also note 20 below. lb. Power neutral and green wire ground are to be isolated from each other. Neutral to be isolated from Panel Board by removing grounding screw in bar. 2. 00 Outlet location for 115v, 20 Amp service from power service panel. Mount 5'0'above floor. See sheet 3 for typical detail. 3. Outlet location for 115v, 15Amp service from power service panel. Mount 5'0' above floor. See sheet 3 for typical detail. 4. Ground wire shall be No. 6AWG Insulated, connected to ground bar on outside of Power Service Panel and run to the closest approved ground as designated by the Building Industry Consultant. If run in metallic conduit, both ends of this conduit must be bonded to this ground wire. 5. • Plywood Backboards to be x x 3/4" 6. E-911 Answering equipment locations must be ready three (3) weeks prior to service date. 7. The maximum cabinet weight is 500 lbs/cabinet. The customer shall be responsible for the structural ability of the building to carry posted load. 8. Shaded area shall not be used for non-telephone company material or equipment. 9. Equipment room ceiling and walls shall be painted or have comparable covering. 10. Floor covering to be asphalt tile or equivalent. 11. Lighting (flourescent preferred) to be minimum of 70 foot candles measured 3'0" above floor for equipment area and 40 foot candles for console area. 12. Air conditioning is required capable of maintaining the room ambient temperature in the range of 65F to 95F with relative humidity in the range of 20 to 60 percent. The heat dissipation per cabinet is 1707 BTU/HR. 13. Equipment room clear ceiling height to be a minimum of 7'6". 14. Equipment room door shall be equipped with a lock. 15. . Conduit shall contain a pull line and have no more than two 90 sweep elbows between ends of conduit or pull boxes. Requirements are shown on floor plan. 16. A separation of not less than ten (10) ,feet shall be . maintained between cabinets and all models of office copying machines, with consideration given to the flow of exhausted air and rebound from nearby walls and surfaces. SHEET 2 (Con't) 17. E-911 equipment room shall be ready four (4) weeks prior to service date. 18. Customer is responsible to provide and maintain fire extinguisher in conformance with OSHA standards. 19. Failure to meet any of the listed requirements may result in a delayed service date. No changes shall be made on this floor plan without the prior consent of the Telephone Company BIC Engineer (see note 20) . Acceptance of this floor plan by the Telephone Company does not constitute any agreement regarding sation wiring arrangements. Said station wiring arrangements shall be in accordance with applicable tariff filings. 20. The customer's electrician shall contact Southern Bell's Building Industry Consultant on telephone number for obtaining the required copper bars and arranging for a joint electrical inspection. 21. Provide a 115v, 15A service outlet at each ANI-ALI display station location for an associated power supply that draws 1 Amp or less. 22. The E-911 equipment room shall be free of large electro magnetic fields, (induction heaters, radio or TV transmitters, nonsynchronous motors or generators). The RF field strength must be less than 3.0 V/m volts per meter as measured on a standard field strength meter. (7C7P8)mf CUSTOMER PROVIDED AC POWER DISTRIBUTION AND t GROUNDING REQUIREMENTS FOR E-911 ITE-EQ4 or equivalent Panel Board equipped with one (1) 20 q piled Amp 6two(2) 15 Amp • singlepole, thermal magnetic, circuit breakers t.. 115 VAC (ITE QP1-B020 or equivalent) and(2)Copper 115 VAC Ground Bars. See Note 21 for obtaining ground bars. Sheet 4 NEUTRAL I 12 Ga(Max 20'Run) Hubbell IG2310__ -- receptacles locate as Neutral Bar shown en Sheet 2 W ` t 1 Z O • ( -� G Q Cab 0 o Cab 0 • r BK d� F BK • • • o .o �20A bee g. 1 cet N 1.1 W en • Cab 1 w BK �� t BK 0 0 ab 1 .c a _ 15A a a G - °+ 0 .:i Hubbell IG 5252 Recpt. c> u • E/W 5-7 Cover Plate to d .� Location Shown on Sheet 2 co u olio.ic Separate Green wire to 3 A 8 . each receptacle. This wire must be provided. • nsTA� ; Rubbel IG 5252 Recpt. E/W 5-7 cover plate.Locatioa 15A _0 '0 W Shown on Sheet 2. G (Ground) 4---0b Inc o DATAPHONE -0 0 0 ® a _ Note: ® G Continuous conduit or other metallic enclosures Note • may be used to replace 4 only this green wire ground. • MOUNTING ARRANGEMENT FOR FIG I GROUND BARS AC LOAD I 4STAR WASHERS USA.43 eo~ol CENTER OUTSIDE ICI REQ'D PER SCREW n.. 4 M IR son- M a. .� •.e• .fv . .u. t.wbe. .f soLl WALL (8 TOTAL) r j.msli.A. �� .I I creme r I I OUNTING SCREWS n u 11 . j . .. (2 REQ.... d) to Popov* GROUND BARS To Be Copper Only. See Note 2O: • j • i • • EXIST WC" NbT E 2 1s1DIE 3 WALL 7 A Iv I A B S 4' x 8' R. 3t 4•• Ri. NO7E 4- Z� CAB i CAg G F3PWESORiZD NOTE 2- NUM S • • • • • , -, • FLOOR GEARING AREA CHART T ELCO" APPROVAL �2•-g": SINGLE EQUIPMENT ENGR'G', o DATE CABINET —'� MKTG DATE 500LSS 2 if 0" PLANT Cu$TV La 13 11C3rC>C:/LS /0• TML 3TIIUCTU AL CarualTr� PRELIMINARY FLOOR •PLAN OI ?LW TO Mat ►03T[0 LO. 0 FOR NEW E 911 CUS TOME R APPROVAL CUSTOMER' ADDRESS: - ' • COMPANY . REPRESENTATIVE CITY ISSUE Nb. 1111 , Eli G DATE TITLE DATE 3