HomeMy WebLinkAboutDocumentation_Miscellaneous_Tab 3_1/29/1996 • VILLAGE OF TEQUESTA, PRELIMINARY SPACE NEEDS PROGRAM • VILLAGE HALL SPACE/AREA REQUIREMENTS SF Assignable Rooms/Areas Administration Lobby 200 Receptionist/Telephone Operator 150 Village Manager(inc. bathroom) 300 Conference Room 220 Office/Library For Mayor&Council • 170 Secretarial/General Office 270 File Room 800 Storage Room For Paper/Supplies Etc 200 Copy/Reproduction 140 Clerk Office 240 Record Retention (active hardcopy only) 120 Note: Additional Storage In New Public Works Garage, Shared w/ Finance&Water Depts. Vault(Fireproof) 140 Personnel Director 200 Clerk/Secretary (To Pers. Dir.) 180 Subtotal 3,330 Commission Chambers 2,000 Subtotal 2,000 Purchasing&Finance Purchasing Agent 200 Finance Director • 220 Finance Clerks (2) 300 Spare Office 200 Computer Room 120 Record Storage 140 Vault(For Computer Back-Up Tapes Etc) 30 Conference Room (Divisible/Shared, 200 Used By Auditors Etc) Storage (Not Remote) 300 Subtotal 1,710 • • VILLAGE OF TEQUESTA, PRELIMINARY SPACE NEEDS PROGRAM VILLAGE HALL (continued) SPACE/AREA REQUIREMENTS Assignable Rooms/Areas Community Development Waiting/Reception 190 Conference Room (Adjacent Waiting 150 For Contractors, Architects, Attorneys, Etc) Planner 200 Secretary/Admin. (2 People; 240 For Occupational Licensing, Permits, Etc) Machine/File Room (Soundproof, 280 Printers, Microfilm, Files, Etc) Inspector's Office 220 Deputy Building Official 180 Occupation/Lic. Inspector 120 Plan Review Room and Reference Library 200 Office Supplies 40 General Storage 150 Subtotal 1,970 Public Works& Water Utilities Waiting/Reception 120 Customer Service (2 People) 300 Secretary (For 3 To 5 People) 120 Copy Room (Fax Machine/Supplies) 120 Water System Manager 190 Distribution Supervisor(In New 0 Public Works Garage) Work Room 200 Water Dept. Storage 120 Stormwater Utility Director 190 Stormwater Utility Dir. Secretary 120 Accounts Supervisor 150 Public Works Director 190 Public Works Field Inspector(In New 0 Public Works Garage) Public Works Dept. Storage 120 Training/Conference Room (Shared) 200 Subtotal 2,140 Employee Lounge/Break Room 220 (Shared By All Building Staff) Subtotal 220 Total:Program Areas 11,370 SF VILLAGE OF TEQUESTA, PRELIMINARY SPACE NEEDS PROGRAM VILLAGE HALL (continued) SPACE/AREA REQUIREMENTS Unnassignable Rooms/Areas Assume 65% Building Efficiency; • 6,122 SF Add 35% For Mech. &Elect. Rooms, Corridors, Public Rest- rooms, all Construction Etc. (Incl. Stairs&Elevator If 2 Stories) Total Est.Gross SF 17,492 SF* • * NOTE If The Building Efficiency Is 60% In Lieu Of 65%, The Est. Gross SF Is 18,670 SF VILLAGE OF TEQUESTA, PRELIMINARY SPACE NEEDS PROGRAM • PUBLIC SAFETY BUILDING (FIRE& POLICE) SPACE/AREA REQUIREMENTS SF Assignable Rooms/Areas Fire Department Administration Lobby/Waiting 120 First Aid Room 100 Chief's Office/Fire Marshall 200 Lieutenant's Offfice 150 Training Officer 150 Spare Office (Size To Accomodate Future EMS Offic 150 Secretary/Clerical 200 Work Room: Copy Machine, Paper Storage 120 Classroom/Multi-use(Possible Share 250 With Police) AN Storage 100 Report Writing Room/Conference Room 150 File Room 120 Subtotal 1,810 Living Quarters Kitchen ' 150 Dining 200 Day Room 400 Dormitory (6-8 People, 10 For Emergencies) 900 Exercise Room (Possible Share With Police Dept) 300 Shift Commander Office 150 Employee Toilets/Showers/Lockers (Men &Women) 450 Subtotal 2,550 Apparatus&Related Spaces Apparatus (4 Bays, 72 Foot Length) 4,608 Air Filling Station 100 Emergency Shower 40 Bunker Gear 200 Laundry 80 Decontamination Room 80 Emergency Generator(Can Combine 150 Space With Police Dept Gen.) Hazmat Storage (Can Be Separate Building) 400 Subtotal 5,658 Total: Program Areas 10,018 SF • • VILLAGE OF TEQUESTA, PRELIMINARY SPACE NEEDS PROGRAM PUBLIC SAFETY BUILDING (FIRE&POLICE) continued Fire Department Unnassignable Rooms/Areas Assume 70% Building Efficiency For Admin. • &Living Quarters Add 30% 1,869 SF Assume 90% Building Efficiency For Apparatus &Related Spaces Add 10% 629 SF Total Est. Fire Dept.Gross SF 12,515 SF NOTE: Separate Training Tower(15' X 16' Footprint) 256 SF SPACE/AREA REQUIREMENTS Assignable Rooms/Areas Police Department Lobby/Waiting 175 Public Meeting Room (Reporters Etc) 64 Chief's Office 200 Conference Room 150 Secretary/Computer Operator 120 Office, Lieutenant 144 Office, Asst. Chief 180 Office, Spare 144 Evidence Locker(Storage) 100 Evidence Processing (Lab) 100 Detective Bureau Office 240 (1 Now, Design For 2 People) Detective Interview/Interrogation 100 (One Way Mirror To Detective's Office) Detective Equipment Room (Storage) 100 Armory (Weapons&Ammunitions Storage) 70 Indoor Shooting Range w/Control Room 1,700 (3 Booths) Cell Blocks#1 &#2 144 Code Enforcement Officer 144 Exercise Room (Possible Sharing With Fire Dept.) 300 Employee Restrooms, Lockers, Showers 500 (Men &Women) Employee Lounge/Break Room 144 Records Storage (Active&Archive) 120 Dispatch Center(Communications Room) 240 Dispatcher Locker Room 36 VILLAGE OF TEQUESTA, PRELIMINARY SPACE NEEDS PROGRAM PUBLIC SAFETY BUILDING (FIRE&POLICE) continued SPACE/AREA REQUIREMENTS-continued Police Department 911 Equipment Room 36 Dispatch Storage (Comm. Office Supplies) 36 Training/Classroom (Possibly 170 Share With Fire Dept) Patrol Sergeants Office 170 Patrol Squad Room (Incl. Report Writing) 250 DUI Breathalizer/Video Room 130 Patrol Interrogation Room 100 Patrol Process Room (Prisoner) 100 Patrol Interview Room (Also Juvenile Holding) 100 Sally Port/Impound Garage (2 Bays) 750 Note: There Is a Storage Bay For Police In The New Public Works Garage Found Property/Bicycle Storage) 200 Garage Storage (Oil, Chemicals, Tools, Etc) 48 Garage Storage (Spare Or Expandable Space) 80 Emergency Generator Room 110 (May Be Combined With Fire Dept. Gen.) Subtotal 7,495 SF Unnassignable Rooms/Areas Assume 65% Building Efficiency For Police Add 35% 4,036 SF Total Est. Police Dept. Gross SF 11,531 SF Total Est. Gross SF, Fire&Police 24,046 SF NOTE: Future Fuel Storage&Dispensing Systems Off Site at Public Works Garage VILLAGE OF TEQUESTA, PRELIMINARY SPACE NEEDS PROGRAM PUBLIC WORKS GARAGE SPACE/AREA REQUIREMENTS SF Assignable Rooms/Areas Public Works Storage/Garage 3,600 (3, 20' *60' Bays) Police Storage 600 (1/2,Of 20' *60' Bay) Public Works Parts Room 90 Water Dept. Parts Room 90 Meter Test Room 150 Office/Work Rm (2) 196 Office 192 Secretary 120 Break Room 140 Toilets/Showers (Men &Women) 195 Subtotal, 1st Floor 5,373 SF Mezzanine Storage For Village Hall Records/Files 2,300 (1200 sf Is Fire Rated/Secure Storage) Subtotal 7,673 SF Unnassignable SF Approx. 73.41% Building Efficiency 1,946 SF Add 26.59% Total Est.Gross SF (Footprint) 7,320 SF Total Est. Building Gross Sf (Incl. Mezz.) 9,620 SF (7320 SF Footprint&2300 SF Mezz) Note: Flammable Storage Building 200 SF • 6 VILLAGE OF TEQUESTA, PRELIMINARY SPACE NEEDS PROGRAM PUBLIC SAFETY APARTMENTS SPACE/AREA REQUIREMENTS SF Assignab►e Rooms/Areas Apartment 8 units Living Area 275 Kitchen/Dining 225 Bedroom 200 Bath 50 Utility 50 Subtotal, 1 unit 800 Total 8 units 6,400 SF Unnassignable SF Approx. 60% Building Efficiency 4,267 SF Add 40% Total Est.Gross SF 10,667 SF VILLAGE OF TEQUESTA, PRELIMINARY SPACE NEEDS PROGRAM ESTIMATED CONSTRUCTION COSTS Scheme'A-1' SF COST/SF COST Public Safety Bldg Building Fire 12,515 90 1,126,350 Police 11,531 100 1,153,100 Furn &Equip (Fire) 5,006 20 100,120 Furn &Equip (Police) 6,300 20 126,000 Site work Assume 25% Of Const Cost 569,863 Subtotal Public Safety Bldg 3,075,433 NOTE: Fire Training Tower 300 120 36,000 36,000 Public Works Garage Building Garage 7,320 * 40 292,800 Flammable Storage Bldg 200 35 7,000 Furn &Equip 0 Site work (Including Water/Sewer, Fencing, Sign Permits etc.) 129,000 Subtotal Public Works Garage 428,800 * NOTE: 7320 SF Is Footprint, Total Bldg. SF is 7320 SF + 2300 SF Mezz Storage = 9620 SF NOTE: Price Of Future Aboveground Fuel Storage System 50,000 (2) 2,000 Gallon Aboveground Fuel Storage Tanks Price Includes Slab, Related Electrical, and Installation Demolition Costs Existing Garage 20,000 Existing Village Hall 40,000 Existing Village Hall Annex 33,000 Existing Storage Tank Controls 2,000 Subtotal, Demolition Costs 95,000 Phasing Considerations lump sum 80,000 Total Est.Const.Costs (Inc! Demo,Furn &Equip) 3,765,233 Add 10% Contingency 376,523 Subtotal 4,141,756 Add Misc. Costs and Prof Fees 455,593 Total Est. Project Costs 4,597 349 VILLAGE OF TEQUESTA, PRELIMINARY SPACE NEEDS PROGRAM ESTIMATED CONSTRUCTION COSTS Scheme'A-2' SF COST/SF COST Public Safety Bldg Building Fire 12,515 90 1,126,350 Police 11,531 100 1,153,100 Furn &Equip (Fire) 5,006 20 100,120 Furn &Equip (Police) 6,300 20 126,000 Site work Assume 25%Of Const Cost 569,863 Subtotal Public Safety Bldg 3,075,433 NOTE: Fire Training Tower 300 120 36,000 36,000 Public Safety Apts. Building New construction 10,667 80 853,360 Furn &Equip Site work Assume 10%Of Const Cost 85,336 • Subtotal, Public Safety Apts. 938,696 * NOTE: Calculations Based On Unfurnished Apartments Public Works Garage Building Garage 7,320 * 40 292,800 Flammable Storage Bldg 200 35 7,000 Furn &Equip 0 Site work (Including Water/Sewer, Fencing, Sign Permits etc.) 129,000 Subtotal Public Works Garage 428,800 * NOTE: 7320 SF Is Footprint, Total Bldg. SF is 7320 SF + 2300 SF Mezz Storage = 9620 SF NOTE: Price Of Fuel Storage System 50,000 (2) 2,000 Gallon Aboveground Fuel Storage Tanks Price Includes Slab, Related Electrical, and Installation VILLAGE OF TEQUESTA, PRELIMINARY SPACE NEEDS PROGRAM ESTIMATED CONSTRUCTION COSTS Scheme'A-2' -Continued Demolition Costs Existing Garage 20,000 Existing Village Hall 40,000 Existing Village Hall Annex 33,000 Existing Water Storage Tank Control Relocation 2,000 Subtotal, Demolition Costs 93,000 Phasing Considerations lump sum 80,000 Total Est.Const. Costs (Incl Furn &Equip) 4,701,929 Add 10% Contingency 470,193 Subtotal 5,172,121 Add Misc. Costs and Prof Fees 568,933 Total Est. Project Costs 5,741,055 VILLAGE OF TEQUESTA, PRELIMINARY SPACE NEEDS PROGRAM ESTIMATED CONSTRUCTION COSTS Scheme'B' SF COST/SF COST Public Safety Bldg Building Fire 12,515 90 1,126,350 Police 11,531 100 1,153,100 Furn &Equip (Fire) 5,006 20 100,120 Furn &Equip (Police) 6,300 20 126,000 Sitework • Assume 25%Of Const Cost 569,863 Subtotal, Public Safety Bldg 3,075,433 NOTE: Fire Training Tower 300 120 36,000 36,000 Public Safety Apts. Building Village Hall Annex-Renov. 4,104 50 205,200 New construction 6,562 80 524,960 Furn &Equip Sitework Assume 25%Of Const Cost 182,540 Subtotal Public Safety Apts. 912,700 * NOTE: Calculations Based On Unfurnished Apartments Public Works Garage Building Garage 7,320 * 40 292,800 Flammable Storage Bldg 200 35 7,000 Sitework (Inca Water/Sewer, Fencing, 129,000 Sign, Permits, etc) Subtotal Public Works Garage 428,800 * NOTE: 7320 SF Is Footprint, Total Bldg. SF is 7320 SF + 2300 SF Mezz Storage = 9620 SF NOTE: Price Of Future Aboveground Fuel Storage System 50,000 (2) 2,000 Gallon Aboveground Fuel Storage Tanks Price Includes Slab, Related Electrical, and Installation Cost VILLAGE OF TEQUESTA, PRELIMINARY SPACE NEEDS PROGRAM ESTIMATED CONSTRUCTION COSTS Scheme'B' Demolition Costs Existing Garage 20,000 Existing Village Hall 40,000 Existing Water Storage Tank Controls Relocation 2,000 Subtotal, Demolition Costs 42,000 Phasing Considerations lump sum 80,000 Total Est.Const.Costs (Incl Demo.,Furn &Equip) 4,624,933 Add 10%Contingency 462,493 Subtotal 5,087,426 Add Misc. Costs and Prof. Fees 559,617 Total Est.Project Costs 5,647,043 • VILLAGE OF TEQUESTA, PRELIMINARY SPACE NEEDS PROGRAM ESTIMATED CONSTRUCTION COSTS Scheme'C' SF COST/SF COST Public Safety Bldg Building Fire 12,515 90 1,126,350 Police-Village Hall Renov. 4,964 , 60 297,840 New const. 6,567 100 656,700 Furn &Equip (Fire) 5,006 20 100,120 Furn &Equip (Police) 6,300 20 126,000 Sitework Assume 25%Of Const Cost 520,223 Subtotal Public Safety Bldg 2,827,233 NOTE:Fire Training Tower 300 120 36,000 36,000 Public Safety Apts. Building Village Hall Annex-Renov. 4,104 60 246,240 New construction 6,562 80 524,960 Furn&Equip Sitework Assume 25%Of Const Cost 192;800 Subtotal, Public Safety Apts. 964,000 * NOTE: Calculations Based On Unfurnished Apartments Public Works Garage Building Garage 7,320 * 40 292,800 Flammable Storage Bldg 200 35 • 7,000 Sitework (Ind Water/Sewer, Fencing, 129,000 Sign, Permits, etc) Subtotal, Public Works Garage 428,800 * NOTE: 7320 SF Is Footprint,Total Bldg. SF is 7320 SF + 2300 SF Mezz Storage = 9620 SF NOTE: Price Of Future Aboveground Fuel Storage System 50,000 (2) 2,000 Gallon Aboveground Fuel Storage Tanks Price Includes Slab, Related Electrical, and Installation VILLAGE OF TEQUESTA, PRELIMINARY SPACE NEEDS PROGRAM ESTIMATED CONSTRUCTION COSTS Scheme'C'-Continued Demolition Costs Existing Garage 20,000 Existing Water Storage Tank Controls Relocation 2,000 Subtotal, Demolition Costs 22,000 Hurricane Hardening 150,000 Phasing Considerations lump sum 80,000 Total Est.Const.Costs (Intl Furn&Equip) 4,508,033 Add 10%Contingency 450,803 Subtotal 4,958,836 Add Misc Costs and Prof Fees 545,472 Total Est. Project Costs 5,504,308 VILLAGE OF TEQUESTA, PRELIMINARY SPACE NEEDS PROGRAM ESTIMATED CONSTRUCTION COSTS Scheme'D' SF COST/SF COST Public Safety Bldg Building ::Fire 12,515 90 1,126,350 Police-Village Hall Renov. 4,964 60 297,840 New const. 6,567 100 656,700 Furn &Equip (Fire) 5,006 20 100,120 Furn &Equip (Police) 6,300 20 126,000 Sitework Assume 25%Of Const Cost 520,223 Subtotal, Public Safety Bldg 2,827,233 NOTE: Fire Training Tower 300 120 36,000 36,000 Public Works Garage Building Garage 7,320 * 40 292,800 Flammable Storage Bldg 200 35 7,000 Sitework (Incl Water/Sewer, Fencing, Sign, Permits, etc.) 129,000 Subtotal, Public Works Garage 428,800 * NOTE: 7320 SF Is Footprint, Total Bldg. SF is 7320 SF + 2300 SF Mezz Storage = 9620 SF NOTE: Price Of Future Aboveground Fuel Storage System 50,000 (2) 2,000 Gallon Aboveground Fuel Storage Tanks Price Includes Slab, Related Electrical, and Installation Demolition Costs Existing Garage 20,000 Existing Village Hall Annex 40,000 Existing Water Storage Tank Controls 2,000 Subtotal, Demolition Costs 62,000 Hurricane Hardening lump sum 200,000 Phasing Considerations lump sum 80,000 Total Est.Const.Costs (Inc! Demo., Furn&Equip) 3,634,033 Add 10%Contingency 363,403 Subtotal 3,997,436 Add Misc Costs and Prof Fees 439,718 Total Est.Project Costs 4,437,154 1 1 300.0' • - s SCHEME A-1 • 0: 0•4 • NEW PUBLIC SAFETY BUILDING PARKING 70 9'X18' SPACES 6 ACCESSIBLE SPACES I :i +9 POLICE VEHICLE SPACES Cli . eo SO0.000TA GNK ALLON �� • WATER ® o .. 2 I / EXISTING ANNEX BLDG. q Q o i . n O'ZOD. TO BE REMOVED m e 3 T u I 3 ® 4 1.4 0;i II m°4 I I I I IPI�m pII F= VEHICLES L _ I1EXISTING GARAGE11/4: _ a4— O — O ,:., ® O TO BE REMOVED — • 6 iI III I I I I I III IIIIIIIrI I [ (MILLI I 0•C=D ' - eJ �': I I l 11 1 �I L j 1 1 1) 1� I �. o • i i z 0.4 0. • Q 1 L ...._ ni • I SALLY , �•i —.I PORT m I SHARED t .16 7•4 Id SPACES I \\\\\ CC M STATION POLICE .I� W STATION i • 1—• Q �i EXISTING VILLAGE HALL c/) < TO BE REMOVED I I I III I I �t�,�. �� yJ c Q L __J i 1 II .'I AUTHORN ED u_ . VEHICLES I I I i III I IIH•IUU ..UUI••UU........nnnnor o•/ Q Q @ 6 6'`cia 6 x • p %��IIIf I co w W uw III AUTHORIZED 'i `�'I O I I 1 I t0 •. 0. i VEHICLES • ONLY 174 — i 41 — _ _ YY - ell i 4 ea II. 1 5----"-',"!..........74, --- - — — %TEDUESTA DR._ _ GEE & _ JENSON _ Engineers-Architects- Planners, Inc. CONCEPTUAL SITE PLAN JOB No. 95004.5 SCALE: 1'a 60' CAD FILE SCHA3W1 SHEET Al NUMBER • SHEET OF 7 UMMEMMEM I 300.0' < _I SCHEME,A—Z f' �,4 NEW PUBLIC SAFETY BUILDING PARKING FUTURE' 97 9'X18' SPACES __ IPUBUC I�TE��___ I 6 ACCESSIBLE SPACES ♦ +9 POLICE VEHICLE SPACES Mf I I 1:4 I F 500,000 GALLON �‘l 4:4 i WATER TANK TOWER r II I e 3 3 EXISTING ANNEX BLDG. A • 200.0' TO BE REMOVED �gi H : SECOND FLOOR ADDITION. . V — ® ''1. OVER POLICE STATION r — "1 '.� •:. i-- I g F o U10 [;4 I4:4 4:1 { IIr i.4 / III I+ �'�' I I I Im ®10 I I I ,� I I POLICE ` r �-1 E I VEHICLES EXISTING GARAGE I 1 TO BE REMOVED I RI JI �l JI O �� O��� I IIII I : I I 4 ad . I I I A I II I I I I I I I I I i♦ i♦ I I — . O L ___.(-:—\_. 1 71 I SALLY ^ • • $ Q PORT ®` I.L L_ > • .� .. I CC � I SHARED -� � 0�4 m SPACES W ri W rI APB BAY STATION FIRE POLICE ,�I5 Id I ►� 10//�t�i� I rTA710N STATION COV, Q EXISTING VILLAGE HALL 1 I I l f I 1 LI I yr (rn TO BE REMOVED I I I I I I I T ��- �i., i.♦ Q Si I I ,���'� ,�• Q ca L--J I I AUTHOR!:ED I Q 0 0 .• ( SO VEHICLES Z ►,4 J pi4 0:4 L _J � N ONLY �4 J I t/ cV III' tyPiP:4 i D d I- ;4 E i i © __ ��� W M W W t ` - •� AUTHORIZED ••. I I o 4I 11 I I0 . - IiiiiMi O ►LY � IT 0�� L ,:....:, 04. 4:4 4:4 } 4 il li. / 5---.".0; TEpUESTA DR.--- _ a � '��- `=- GEE & — _ _ JENSON - Engineers—Architects— Planners,Inc. ........ CONCEPTUAL SITE PLAN JOB No. 95004.5 SCALE: 1'-60' CAD FILE SCHA4WI NU A NUMBER /I-�L f SHEET OF MIIIIIIIIIIMI 300.0' `i - • SCHEME B $•! .: NEW PUBLIC SAFETY BUILDING PUBUC SAFETY APARTMENTS (PROVIDED,IN RENOVATED 0.4 EXISTING ANNEX BLDG.) 1 PARKING ♦ �'!':t� 91 9'X18' SPACES 5 ACCESSIBLE SPACES G o I i 9 POLICE VEHICLE SPACES eg 500.000 GALLON m WATER TANK 2ND STORY ti4 �tj n Z n AW ADDITION �� ® - '� n n ABOVE ♦ f{/,r -2 F 'a , u i a FF�ff // ■ 'll E e 1 W I ` r ff,,PUBUC SAFETY �: /fjf /APARTNENTS (' • I __-- — Y/ ■ i H/ / i:1 .# EXISTING GARAGE —1 0 //:f; Q t� ►i! TO BE REMOVED ■ ^ _ IV IN 0:4 I 1 — Q CI— ILA- -� ,° J TA _ � � J IO --, I I I I I I l l l I I�• W PORT _ POUCE ... _ -_�- 173 L.—— —O VEHICLES :4 EXISTING VILLAGE HALL ——— i FIRE �ISHARED POIJCE I �• Q W TO BE REMOVED I I STATION II SPACES STATION C ER APPARATUS it _ �! ►•! 0 AY .... — ._ II i:F1 CC IFU. CC sWAN C7 c0 �= f ® ►•l�111,2 ►:! 4:4 M 04 m ::! 1 1 1 1 1 1,1 III I__ I I III I I I I I I I I I I I / • (/) W •!1 1 1 1 1 .:4 r ••�,,'r,,p! W Si M i! ♦ 4:4 u & t ` 43:) 6 6 C '•! T.I. , , 1 1 1 1 1 1 1 °! CC W V mmEmmlimm AUTHORIZED 1 /1 t UTHORIZ D VEHICLES — ONLY P:4I I NlY hullI,III II II III _ IIIIIIIIBIIIII _ 1 !1,, \ / \ / LEGEND et ... — — — €TEGUESTA DR. — - r`//.f EXISTING BUILDING GEE & , JENSON Engineers—Architects— _ Planners, Inc. eN CONCEPTUAL SITE PLAN JOB No. 95004.5 " SCALE 1'-6o' CAD FILE SCHBTWI SHEETA3 NUMBER SHEET OF MEMMEMEM jf i a !` ' g ' 300.0' • __— _ _ _.� SCHEME C PUBLIC SAFETY BUILDING NEW FIRE DEPARTMENT POLICE DEPARTMENT IN RENOVATED VILLAGE HALL WITH ADDITION li )—r;)::: lr / PUB(PROVLIC SAFETY IN APARTMENTS RENOVATED EXISTING ANNEX BLDG.) S I PARKING E. Ik 92 9'X78' SPACES 3 0 POLICE5 IBVEH CLELE CSPACES 500,000 GALLON (....... 'o 171' i':. WATER TANK i ;_, , m il 200.0' 2ND STORY I ► i I n n ADDITION ' -. _ _ . . _ _._• c o o c E n • 1:3)• [T] //� }.4 o ® ge 6 aFa PUBUC• ENSAFETYr APARTMENTS • / 0:4 11 1 11 ®F r - - 1 - / I A., -7.— t.--/• „,,, EXISTING GARAGE 1 TO BE REMOVED�,! Col = �- ®J t74 .0 �'� I l I I I O`J I_i I S°', Z • (lIIIIIIIIIIII IIII) A 11111111111 ) I P In ;.. Iilill I I ilri 1 I imi I Q_ m .. I I:I- c W • M SALLY PORT o,..1 ►:4 ►7,4 ® t'4 U) "� APPARATUS ►,4 *4 1;4 W a t 'c7'''':'. /.Z/'. /Z:/7!C r� { BAY FIRE FL I � STATION •7 t% STATION I Q 0 0 • AUTHORIZ'd AUTHORS ED Z �,�,y VEHICLES �, ONLY VEHICLES L ) C J r 3 d �..-.,. ONLY ,:! ►d 4 U ilnnullI IlfAIIII1IIII1 [IIII _1 I IIII1IJIiIII 11 11 IIIiin` II CI, I aq� 'I 6' :. J 5 w U �• CL I I I� I Qom ''! O (i� Cyr� �— 0 i I I I i I I •''® cc W 0 = • • ei4r OLICLEES ® �♦ � . mismis AUTHORIZED —VEHICLES � _ a=rincaurn,.._ _ WI ••:, ® I0 �o ONLY o �:4W T _ I_ _ _ — •• 200.0 •:. et ________ \ 540.1' 57.„ - • 3`01,i _ — LEGEND TEQUESTA DR. — J® - f� ou EXITUNe GEE & _ � {.,� STING BUILDING JENSON Engineers—Architects— Planners, Inc. • riN CONCEPTUAL SITE PLAN JOB No. 95004.5 " SCALE: i'-so' CAD FILE SCHCIWI SHEET A4 NUMBER SHEET OF a IIIIIIII 0 M 300.0' _ _ SCHEME D 4 PUBLIC SAFETY BUILDING NEW FIRE DEPARTMENT POLICE DEPARTMENT IN RENOVATED VILLAGE HALL WITH ADDITION PARKING ♦♦ 76 9'X18' SPACES I Mf 4 ACCESSIBLE SPACES CO I ►4 r__ -. 7 I 9+ POLICE VEHICLE SPACES I] 1 w 500.00D GALLON• TOWER > a WATER TANK / " 200.0' TO EXIBEG ANNEX REMOVED BLDG. \ / r 1 : 3 ' ...... / i;4 C )i;} I n S a El 0 a' t G a o c X a mmiiiimi i•4 1.4 47.� ►�4 �!►�1 (� ,. ur Hai 1 I 10 u;4 POLICE i r — — — - VEHICLES ►•� I EXISTING GARAGE # //.\ •fi r1 I TO BE REMOVED—\ ' 1 : I I Ei - 0 ex4 :l �D �� �;� 10 �i� ' 1111i11f1 IIII IIlll �l II mill III I11111 Illlfl1I ! C► o Z I PORT 1 in . L — I CC co I4 W id POLICE APPARATUS FIRE ;1 0:4 MI STATION /'' BAY STATION it /i' '/ f• /rif t cc .//.f; %///' VEHICLES AUTHORIZED 04 '�' ' �O • ! �..t ONLY • • �•. I 4;1 ( _ 1 ( J L 1 _ 1 _ ♦•74 ,•• '• ,•• .I� .L mil. J. ,•• .:4 W AUTHORIZ (�l l I l 1 J��1 ;' j VEHICLES ly _ �J _ 0:4 IT ►.4 .I .I. T 04 � . O� CO AUTHORIZED D 0•il '•` 6 4 ONLY • I 0 �•� — ell ® .....j 200.0' ® OR � r. 11�- _ _ _ 0 ® ARC ..... LEGEND - - - �+ TEGUESTA DR._ _ _ 031:27 _ GEE & L f: OUTI i OF - ti/f/1,.�% Min.. J E N S O N Engineers—Architects— . __ PlOnners, Inc. CONCEPTUAL SIZE PLAN JOB No. 95004.5 iMM a SCALE: 1-= 60' CAD FILE SCHD1W1 SHEETA5 NUMBER f SHEET OF