Loading...
HomeMy WebLinkAboutOrdinance_19-23_2/8/2024 ORDINANCE NO. 19-23 AN ORDINANCE OF THE VILLAGE COUNCIL OF THE VILLAGE OF TEQUESTA, FLORIDA, AMENDING THE VILLAGE CODE OF ORDINANCES AT CHAPTER 14. BUILDINGS AND BUILDING REGULATIONS. ARTICLE II. BUILDINGS. SECTION 14-32 TO ADOPT CHAPTER 1, ADMINISTRATION, OF THE FLORIDA BUILDING CODE. AS AMENDED, IN ACCORDANCE WITH THE REQUIREMENTS OF SEC. 553.73(4)(a) FLORIDA STATUTES; PROVIDING FINDINGS OF FACT; PROVIDING FOR TRANSMISSION OF THIS ORDINANCE TO THE FLORIDA BUILDING COMMISSION; PROVIDING DIRECTION TO THE VILLAGE MANAGER TO ASSURE THAT THIS ORDINANCE IS MADE AVAILABLE TO THE GENERAL PUBLIC IN A USABLE FORMAT; PROVIDING THAT EACH AND EVERY OTHER SECTION AND SUBSECTION OF CHAPTER 14. BUILDINGS AND BUILDING REGULATIONS. SHALL REMAIN IN FULL FORCE AND EFFECT AS PREVIOUSLY ADOPTED; PROVIDING A CONFLICTS CLAUSE, A SEVERABILITY CLAUSE AND AUTHORITY TO CODIFY; PROVIDING AN EFFECTIVE DATE, AND FOR OTHER PURPOSES. WHEREAS, The Florida Building Code, as adopted by the Florida Building Commission and as amended from time to time, governs the design and construction of buildings within the Village of Tequesta; and WHEREAS, Chapter 1 of the Florida Building Code contains the administrative (non-technical) provisions the Florida Building Code, which may be amended by local governments pursuant to the requirements of Sec. 553.73(4)(a), Florida Statutes; and WHEREAS, the Village of Tequesta Building Official has determined that the local amendments to Chapter 1, Administration, of the Florida Building Code contained herein are equal to, or more stringent than the administrative provisions of the Florida Building Code adopted by the Florida Building Commission, and further recommended the adoption of Chapter 1. Administration, of the Florida Building Code as amended herein; and WHEREAS, the Village Council desires to accept the recommendation of the Village Building Official and adopt Chapter 1. Administration, of the Florida Building Code as amended herein; and 1 WHEREAS, the Village Manager is directed to transmit a copy of this ordinance to the Florida Building Commission no later than 30 days after its final adoption, and further to assure that this ordinance is made available to the general public in a usable format immediately upon its final adoption; and WHEREAS, the Village Council desires to adopt this ordinance, and has determined that such adoption will best serve the public welfare. NOW, THEREFORE, BE IT ORDAINED BY THE VILLAGE COUNCIL OF THE VILLAGE OF TEQUESTA, PALM BEACH COUNTY, FLORIDA AS FOLLOWS: Section 1: Chapter 14. Buildings and building regulations of the Code of Ordinances of the Village of Tequesta is hereby amended at Article II. Buildings, Sec. 14- 32, to adopt Chapter 1. Administration, of the Florida Building Code as amended; providing that Chapter 78, Article ll, Sec. 14-32 shall hereafter read as follows: Sec. 14-32. — Reserved Chapter 1. Administration; local amendments. PART 1—SCOPE AND APPLICATION SECTION 101 GENERAL 101.1 Title. These regulations shall be known as the Florida Building Code, hereinafter referred to as "this code." 101.2 Scope. The provisions of this code shall apply to the construction, alteration, relocation, enlargement, replacement, repair, equipment, use and occupancy, location, maintenance, removal and demolition of every building or structure or any appurtenances connected or attached to such buildings or structures in the Village of Tequesta. Exception: 1 . Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories above grade plane in height with a separate means of egress and their accessory structures not more than three stories above grade plane in height, shall comply with the Florida Building Code, Residential. 2. Code Requirements that address snow loads and earthquake protection are pervasive; they are left in place but shall not be utilized or enforced because Florida has no snow load or earthquake threat. 2 101.2.1 Appendices. Provisions in the appendices to the Florida Building Code shall not apply unless specifically adopted. 101.2.2 Florida Building Code, Residential Construction standards or practices which are not covered by Florida Building Code, Residential volume shall be in accordance with the provisions of Florida Building Code, Building. 101.3 Intent. The purpose of this code is to establish the minimum requirements to safeguard the public health, safety and general welfare through structural strength, means of egress facilities, stability, sanitation, adequate light and ventilation, energy conservation, and safety to life and property from fire and other hazards attributed to the built environment and to provide safety to fire fighters and emergency responders during emergency operations. 101.3.1 Quality control. Quality control of materials and workmanship is not within the purview of this code except as it relates to the purposes stated herein. 101.3.2 Warranty and Liability. The permitting, plan review or inspection of any building, system or plan by the Village of Tequesta, under the requirements of this code, shall not be construed in any court as a warranty of the physical condition of such building, system or plan or their adequacy. The Village of Tequesta shall not be liable in tort for damages or hazardous or illegal condition or inadequacy in such building, system or plan, nor for any failure of any component of such, which may occur subsequent to such inspection or permitting. Further, no employee shall be liable in tort for damage from such conditions, in accordance with Section 768.28 Florida Statutes, as may be amended or replaced. 101.4 Referenced codes. The other codes listed in Sections 101.4.1 through 101.4.11 and referenced elsewhere in this code shall be considered part of the requirements of this code to the prescribed extent of each such reference. 101.4.1 Gas. The provisions of the Florida Building Code, Fuel Gas shall apply to the installation of gas piping from the point of delivery, gas appliances and related accessories as covered in this code. These requirements apply to gas piping systems extending from the point of delivery to the inlet connections of appliances and the installation and operation of residential and commercial gas appliances and related accessories. 101.4.2 Mechanical. The provisions of the Florida Building Code, Mechanical shall apply to the installation, alterations, repairs and replacement of mechanical systems, including equipment, appliances, fixtures, fittings and/or appurtenances, including ventilating, heating, cooling, air-conditioning and refrigeration systems, incinerators and other energy-related systems. 101.4.3 Plumbing. The provisions of the Florida Building Code, Plumbing shall apply to the installation, alteration, repair and replacement of plumbing systems, including 3 equipment, appliances, fixtures, fittings and appurtenances, and where connected to a water or sewage system and all aspects of a medical gas system. 101.4.4 Property maintenance. The provisions of the Village of Tequesta Code of Ordinances Article V, Sec. 14-121, and Appendix B shall apply to all matters governing property maintenance. 101.4.5 Fire prevention. For provisions related to fire prevention, refer to the Florida Fire Prevention Code. The Florida Fire Prevention Code shall apply to matters affecting or relating to structures, processes and premises from the hazard of fire and explosion arising from the storage, handling or use of structures, materials or devices; from conditions hazardous to life, property or public welfare in the occupancy of structures or premises; and from the construction, extension, repair, alteration or removal of fire suppression, automatic sprinkler systems and alarm systems or fire hazards in the structure or on the premises from occupancy or operation. 101.4.6 Energy. The provisions of the Florida Building Code, Energy Conservation shall apply to all matters governing the design and construction of buildings for energy efficiency. 101.4.7 Existing buildings. The provisions of the Florida Existing Building Code shall apply to matters governing the repair, alteration, change of occupancy, addition to and relocation of existing buildings. 101.4.8 Accessibility. For provisions related to accessibility, refer to the Florida Building Code, Accessibility. 101.4.9 Manufactured buildings. For additional administrative and special code requirements, see Section 458, Florida Building Code. Building, and Rule 61-41 Florida Administrative Code. 101.4.10 Electrical. The provisions of Chapter 27 of the Florida Building Code, Building Volume shall apply to the installation of electrical systems, including alterations, repairs, replacement, equipment, appliances, fixtures, fittings and appurtenances thereto. 101.4.11 Flood Damage Prevention. The provisions of the Village of Tequesta Code of Ordinances Chapter 78. Article XII shall be considered part of this code relative to flood control. 101.5 Building Official. Whenever, the Building Official is mentioned in this code, it is also intended to mean the Building Official's designee, wherever applicable. SECTION 102 APPLICABILITY 4 102.1 General. Where there is a conflict between a general requirement and a specific requirement, the specific requirement shall be applicable. Where, in any specific case, different sections of this code specify different materials, methods of construction or other requirements, the most restrictive shall govern. 102.1.1 The Florida Building Code does not apply to, and no code enforcement action shall be brought with respect to, zoning requirements, land use requirements and owner specifications or programmatic requirements which do not pertain to and govern the design, construction, erection, alteration, modification, repair or demolition of public or private buildings, structures or facilities or to programmatic requirements that do not pertain to enforcement of the Florida Building Code. Additionally, a local code enforcement agency may not administer or enforce the Florida Building Code, Building to prevent the siting of any publicly owned facility, including, but not limited to, correctional facilities, juvenile justice facilities, or state universities, community colleges, or public education facilities, as provided by law. 102.2 Building. The provisions of the Florida Building Code shall apply to the construction, erection, alteration, modification, repair, equipment, use and occupancy, location, maintenance, removal and demolition of every public and private building, structure or facility or floating residential structure, or any appurtenances connected or attached to such buildings, structures or facilities. Additions, alterations, repairs and changes of use or occupancy group in all buildings and structures shall comply with the provisions provided in the Florida Building Code, Existing Building. The following buildings, structures and facilities, except for those located in a Special Flood Hazard Area are exempt from the Florida Building Code as provided by law, and any further exemptions shall be as determined by the legislature and provided by law: (a) Building and structures specifically regulated and preempted by the federal government. (b) Railroads and ancillary facilities associated with the railroad. (c) Nonresidential farm buildings on farms. (d) Temporary buildings or sheds used exclusively for construction purposes. (e) Mobile or modular structures used as temporary offices, except that the provisions of Part II (Section 553.501-553.513, Florida Statutes) relating to accessibility by persons with disabilities shall apply to such mobile or modular structures. Permits shall be required for structural support and tie down, electric supply and all other such utility connections to such mobile or modular structures as required by this jurisdiction. 5 (f) Those structures or facilities of electric utilities, as defined in Section 366.02, Florida Statutes, which are directly involved in the generation, transmission, or distribution of electricity. (g) Temporary sets, assemblies, or structures used in commercial motion picture or television production, or any sound-recording equipment used in such production, on or off the premises. (h) Chickees constructed by the Miccosukee Tribe of Indians of Florida or the Seminole Tribe of Florida. As used in this paragraph, the term "chickee" means an open-sided wooden but that has a thatched roof of palm or palmetto or other traditional materials, and that does not incorporate any electrical, plumbing, or other non-wood features. (i) Family mausoleums not exceeding 250 square feet (23 m2) in area which are prefabricated and assembled on site or preassembled and delivered on site and have walls, roofs, and a floor constructed of granite, marble, or reinforced concrete. 0) Temporary housing provided by the Department of Corrections to any prisoner in the state correctional system. (k) A building or structure having less than 1,000 square feet (93 m2) which is constructed and owned by a natural person for hunting and which is repaired or reconstructed to the same dimension and condition as existed on January 1, 2011, if the building or structure: 1. Is not rented or leased or used as a principal residence; 2. Is not located within the 100-year floodplain according to the Federal Emergency Management Agency's current Flood Insurance Rate Map; and 3. Is not connected to an off-site electric power or water supply. (1) Service providers of water, sewer, storm, gas, cable, telephone, or other similar utility systems are exempt to the point of service connection for the building or structure. 102.2.1 In addition to the requirements of Section 553.79 and 553.80, Florida Statutes, facilities subject to the provisions of Chapter 395, Florida Statutes, and Part II of Chapter 400, Florida Statutes, shall have facility plans reviewed and construction surveyed by the state agency authorized to do so under the requirements of Chapter 395, Florida Statutes, and Part 11 of Chapter 400, Florida Statutes, and the certification requirements of the federal government. 6 102.2.2 Residential buildings or structures moved into or within the Village of Tequesta shall not be required to be brought into compliance with the state minimum building code in force at the time the building or structure is moved, provided: 1. The building or structure is structurally sound and in occupiable condition for its intended use; 2. The occupancy use classification for the building or structure is not changed as a result of the move; 3. The building is not substantially remodeled; 4. Current fire code requirements for ingress and egress are met; 5. Electrical, gas and plumbing systems meet the codes in force at the time of construction and are operational and safe for reconnection; and 6. Foundation plans are sealed by a professional engineer or architect licensed to practice in this state, if required by the Florida Building Code, Building for all residential buildings or structures of the same occupancy class. 7. The requirements of Florida Building Code, Existing Building Volume, are also satisfied. 102.2.3 The Building Official shall apply the same standard to a moved residential building or structure as that applied to the remodeling of any comparable residential building or structure to determine whether the moved structure is substantially remodeled. The cost of the foundation on which the moved building or structure is placed shall not be included in the cost of remodeling for purposes of determining whether a moved building or structure has been substantially remodeled. 102.2.4 This section does not apply to the jurisdiction and authority of the Department of Agriculture and Consumer Services to inspect amusement rides or the Department of Financial Services to inspect state-owned buildings and boilers. 102.2.5 Each enforcement district or local enforcement agency shall be governed by a board, the composition of which shall be determined by the affected localities. 1 . The Village of Tequesta may adopt rules granting to the owner of a single-family residence one or more exemptions from the Florida Building Code relating to: a. Addition, alteration, or repairs performed by the property owner upon his or her own property, provided any addition or alteration or repair shall not exceed 1,000 square feet (93 ml) or the square footage of the primary structure, whichever is less. b. Addition, alteration, or repairs by a non-owner within a specific cost limitation set by rule, provided the total cost shall not exceed $5,000 within any 12-month period. c. Building plans review and inspection fees. 2. However, the exemptions under subparagraph 1 do not apply to single-family residences that are located in mapped flood hazard areas, as defined in the code, unless the enforcement district or local enforcement agency has determined that the work, which is otherwise exempt, does not constitute a substantial improvement, including the repair of substantial damage, of such single-family residences. 3. Each code exemption, as defined in sub-subparagraphs 1 a, 1 b, and 1 c shall be certified to the local board 10 days prior to implementation and shall only be effective in the territorial jurisdiction of the enforcement district or local enforcement agency implementing it. 4. However, each enforcement district or local enforcement agency may establish an alternative permitting program for replacing nonstructural components of building systems in a residential dwelling unit. A licensed contractor performing such work for the resident shall also be exempt from individual permits and inspections if either the owner or the licensed contractor obtains a valid Annual Permit per Section 105.1.1 of this code and all such work is reported as required in Section 105.1.2 of this code for compliance evaluation. No added capacity, system expansion or new building work of any type shall be excluded from individual permit and inspection by this provision. 102.2.6 This section does not apply to swings and other playground equipment accessory to a one- or two-family dwelling. Exception: Electrical service to such playground equipment shall be in accordance with Chapter 27 of this code. 102.3 Application of references. References to chapter or section numbers, or to provisions not specifically identified by number, shall be construed to refer to such chapter, section or provision of this code. 102.4 Referenced codes and standards. The codes and standards referenced in this code shall be considered part of the requirements of this code to the prescribed extent of each such reference and as further regulated in Sections 102.4.1 and 102.4.2. 102.4.1 Conflicts. Where conflicts occur between provisions of this code and referenced codes and standards, the provisions of this code shall apply. 8 102.4.2 Provisions in referenced codes and standards. Where the extent of the reference to a referenced code or standard includes subject matter that is within the scope of this code or the Florida Codes listed in Section101.4, the provisions of this code or the Florida Codes listed in Section 101.4, as applicable, shall take precedence over the provisions in the referenced code or standard. 102.5 Partial invalidity. In the event that any part or provision of this code is held to be illegal or void, this shall not have the effect of making void or illegal any of the other parts or provisions. 102.6 Existing structures. The legal occupancy of any structure existing on the date of adoption of this code shall be permitted to continue without change, except as is specifically covered in this code, the Florida Building Code, Existing Building, the Florida Fire Prevention Code, and the provisions of the Village of Tequesta Code of Ordinances Article V, Sec. 14-121, and Appendix B. 102.6.1 Buildings not previously occupied. A building or portion of a building that has not been previously occupied or used for its intended purpose in accordance with the laws in existence at the time of its completion shall comply with the provisions of the Florida Building Code or Florida Residential Code, as applicable, for new construction or with any current permit for such occupancy. 102.6.2 Buildings previously occupied. The legal occupancy of any building existing on the date of adoption of this code shall be permitted to continue without change, except as otherwise specifically provided in this code, the Florida Fire Prevention Code, the Village of Tequesta Code of Ordinances Article V, Sec. 14-121, and Appendix B, or as is deemed necessary by the Building Official for the general safety and welfare of the occupants and the public. 102.7 Relocation of manufactured buildings. 1. Relocation of an existing manufactured building does not constitute an alteration. 2. A relocated building shall comply with wind speed requirements of the new location, using the appropriate wind speed map. If the existing building was manufactured in compliance with the Standard Building Code (prior to March 1, 2002), the wind speed map of the Standard Building Code shall be applicable. If the existing building was manufactured in compliance with the Florida Building Code (after March 1, 2002), the wind speed map of the Florida Building Code shall be applicable. 3. A relocated building shall comply with the flood hazard area requirements of the new location, if applicable. 9 102.8 Existing mechanical equipment. The Village of Tequesta may not require that existing mechanical equipment located on or above the surface of a roof be installed in compliance with the requirements of the Florida Building Code except during reroofing when the equipment is being replaced or moved during reroofing and is not in compliance with the provisions of the Florida Building Code relating to roof-mounted mechanical units. PART 2—ADMINISTRATION AND ENFORCEMENT SECTION 103 DEPARTMENT OF BUILDING SAFETY 103.1 Creation of enforcement agency. The Department of Building Safety is hereby created and the official in charge thereof shall be known as the Building Official. 103.2 Appointment. The Building Official shall be appointed by the chief appointing authority of the jurisdiction. 103.3 Deputies. In accordance with the prescribed procedures of this jurisdiction and with the concurrence of the appointing authority, the Building Official shall have the authority to appoint a deputy Building Official, the related technical officers, inspectors, plan examiners and other employees. Such employees shall have powers as delegated by the Building Official. For the maintenance of existing properties, see the provisions of the Village of Tequesta Code of Ordinances Article V, Sec. 14-121, and Appendix B shall apply to all matters governing property maintenance. 103.4 Restrictions on employees. (Reserved). SECTION 104 DUTIES AND POWERS OF THE BUILDING OFFICIAL 104.1 General. The Building Official is hereby authorized and directed to enforce the provisions of this code. The Building Official shall have the authority to render interpretations of this code and to adopt policies and procedures in order to clarify the application of its provisions. Such interpretations, policies and procedures shall be in compliance with the intent and purpose of this code. Such policies and procedures shall not have the effect of waiving requirements specifically provided for in this code. 104.2 Applications and permits. The Building Official shall receive applications, review construction documents and issue permits for the erection, and alteration, demolition and moving of buildings, structures, and service systems, inspect the premises for which such permits have been issued and enforce compliance with the provisions of this code. 104.2.1 Determination of substantially improved or substantially damaged existing buildings and structures in flood hazard areas. For applications for reconstruction, rehabilitation, repair, alteration, addition or other improvement of 10 existing buildings or structures located in flood hazard areas, the Building Official shall determine if the proposed work constitutes substantial improvement or repair of substantial damage. Where the Building Official determines that the proposed work constitutes substantial improvement or repair of substantial damage, and where required by this code, the Building Official shall require the building to meet the requirements of Florida Building Code Section 1612. 104.3 Notices and orders. The Building Official shall issue all necessary notices or orders to ensure compliance with this code. 104.4 Inspections. The Building Official shall make all of the required inspections, or the Building Official shall have the authority to accept reports of inspection by approved agencies or individuals. Reports of such inspections shall be in writing and be certified by a responsible officer of such approved agency or by the responsible individual. The Building Official is authorized to engage such expert opinion as deemed necessary to report upon unusual technical issues that arise, subject to the approval of the appointing authority. 104.5 Identification. The Building Official shall carry proper identification when inspecting structures or premises in the performance of duties under this code. 104.6 Right of entry. Where it is necessary to make an inspection to enforce the provisions of this code, or where the Building Official has reasonable cause to believe that there exists in a structure or upon a premises a condition which is contrary to or in violation of this code which makes the structure or premises unsafe, dangerous or hazardous, the Building Official is authorized to enter the structure or premises at reasonable times to inspect or to perform the duties imposed by this code, provided that if such structure or premises be occupied that credentials be presented to the occupant and entry requested. If such structure or premises is unoccupied, the Building Official shall first make a reasonable effort to locate the owner or other person having charge or control of the structure or premises and request entry. If entry is refused, the Building Official shall have recourse to the remedies provided by law to secure entry. 104.7 Department records. The Building Official shall keep official records of applications received, permits and certificates issued, fees collected, reports of inspections, and notices and orders issued. Such records shall be retained in the official records for the period required for retention of public records per Chapter 119, Florida Statutes ("Public Records Law"). 104.8 Liability. The Building Official, member of the board of appeals or employee charged with the enforcement of this code, while acting for the jurisdiction in good faith and without malice in the discharge of the duties required by this code or other pertinent law or ordinance, shall not thereby be civilly or criminally rendered liable personally and is hereby relieved from personal liability for any damage accruing to persons or property as a result of any act or by reason of an act or omission in the discharge of official duties. Any suit instituted against an officer, employee, or board member because of an act 11 performed by that officer, employee, or board member in the lawful discharge of duties and under the provisions of this code shall be defended by legal representative of the jurisdiction until the final termination of the proceedings. The Building Official or any subordinate shall not be liable for cost in any action, suit or proceeding that is instituted in pursuance of the provisions of this code. 104.8.1 Legal defense. Any suit or criminal complaint instituted against an officer, employee, or board member because of an act performed by that officer, employee, or board member in the lawful discharge of duties and under the provisions of this code shall be defended by legal representatives of or provided by the Village of Tequesta until the final termination of the proceedings. The Building Official or any subordinate shall not be liable for cost in any action, suit or proceeding that is instituted in pursuance of the provisions of this code. 104.9 Approved materials and equipment. Materials, equipment and devices approved by the Building Official shall be constructed and installed in accordance with such approval. 104.9.1 Used materials and equipment. The use of used materials which meet the requirements of this code for new materials is permitted. Used equipment and devices shall not be reused unless approved by the Building Official. 104.10 Modifications. Wherever there are practical difficulties involved in carrying out the provisions of this code, the Building Official shall have the authority to grant modifications for individual cases, upon application of the owner or owner's representative, provided the Building Official shall first find that special individual reason makes the strict letter of this code impractical and the modification is in compliance with the intent and purpose of this code and that such modification does not lessen health, accessibility, life and fire safety, or structural requirements. The details of action granting modifications shall be recorded and entered in the files of the department of building safety. 104.10.1 Flood hazard areas. The Building Official shall coordinate with the floodplain administrator to review requests submitted to the Building Official that seek approval to modify the strict application of the flood resistant construction requirements of the Florida Building Code to determine whether such requests require the granting of a variance pursuant to Section 117 herein-below. 104.11 Alternative materials, design and methods of construction and equipment. The provisions of this code are not intended to prevent the installation of any material or to prohibit any design or method of construction not specifically prescribed by this code, provided that any such alternative has been approved. An alternative material, design or method of construction shall be approved where the Building Official finds that the proposed design is satisfactory and complies with the intent of the provisions of this code, and that the material, method or work offered is, for the purpose intended, not less than the equivalent of that prescribed in this code in quality, strength, effectiveness, fire 12 resistance, durability and safety. Where the alternative material, design or method of construction is not approved, the Building Official shall respond in writing, stating the reasons why the alternative was not approved. 104.11.1 Research reports. Supporting data, where necessary to assist in the approval of materials or assemblies not specifically provided for in this code, shall consist of valid research reports from approved sources. 104.11.2 Tests. Whenever there is insufficient evidence of compliance with the provisions of this code, or evidence that a material or method does not conform to the requirements of this code, or in order to substantiate claims for alternative materials or methods, the Building Official shall have the authority to require tests as evidence of compliance to be made at no expense to the jurisdiction. Test methods shall be as specified in this code or by other recognized test standards. In the absence of recognized and accepted test methods, the Building Official shall approve the testing procedures. Tests shall be performed by an approved agency. Reports of such tests shall be retained by the Building Official for the period required for retention of public records. 104.12 Requirements not covered by code. Any requirements necessary for strength, stability or proper operation of an existing or proposed building, structure, electrical, gas, mechanical or plumbing system, or for the public safety, health and general welfare, not specifically covered by this or other technical codes, shall be determined by the Building Official. SECTION 105 PERMITS 105.1 Required. Any owner or owner's authorized agent who intends to construct, enlarge, alter, repair, move, demolish, or change the occupancy of a building or structure, or to erect, install, enlarge, alter, repair, remove, convert or replace any impact-resistant coverings, electrical, gas, mechanical or plumbing, fire protection system, or accessible or flood resistant site element, the installation of which is regulated by this code, or to cause any such work to be done, shall first make application to the Building Official and obtain the required permit. 105.1.1 Annual facility permit. In lieu of an individual permit for each alteration to an existing electrical, gas, mechanical or plumbing or interior nonstructural office system(s), the Building Official is authorized to issue an annual permit for any occupancy to facilitate routine or emergency service, repair, refurbishing, minor renovations of service systems or manufacturing equipment installations/relocations. The Building Official shall be notified of major changes and shall retain the right to make inspections at the facility site as deemed necessary. An annual facility permit shall be assessed with an annual fee and shall be valid for one year from date of issuance.A separate permit shall be obtained for each facility and for each construction 13 trade, as applicable. The permit application shall contain a general description of the parameters of work intended to be performed during the year. 105.1.2 Annual Facility permit records. The person to whom an annual permit is issued shall keep a detailed record of alterations made under such annual permit. The Building Official shall have access to such records at all times or such records shall be filed with the Building Official as designated. The Building Official is authorized to revoke such permit if code violations are found to exist. 105.1.3 Food permit. In accordance with 500.12, Florida Statutes, a food permit from the Department of Agriculture and Consumer Services is required of any person who operates a food establishment or retail store. 105.1.4 Public swimming pool. The Village of Tequesta may not issue a building permit to construct, develop, or modify a public swimming pool without proof of application, whether complete or incomplete, for an operating permit pursuant to Section 514.031, Florida Statutes. A certificate of completion or occupancy may not be issued until such operating permit is issued. The Village of Tequesta shall conduct their review of the building permit application upon filing and in accordance with Chapter 553, Florida Statutes. The Village of Tequesta may confer with the Department of Health, if necessary, but may not delay the building permit application review while awaiting comment from the Department of Health. 105.2 Work exempt from permit. Exemptions from permit requirements of this code shall not be deemed to grant authorization for any work to be done in any manner in violation of the provisions of this code or any other laws or ordinances of the Village of Tequesta, to include work in any special flood hazard area. Exemptions granted under this section do not relieve the owner or contractor from their duty to comply with applicable provisions of the Florida Building Code, and requirements of the local floodplain management ordinance. As determined by the Building Official, permits shall not be required for the following: Building: 1. Building permits are not required for replacement or repair work having a value of less than $1,000.00, providing, however, that such work will not adversely affect the structural integrity, fire rating, exit access or egress requirements. 2. Cabinets and countertops with no reconfiguration for 1&2 Family Dwellings, painting, papering, carpeting, and similar finish work, with no electrical or plumbing work. 3. Temporary motion picture, television and theater sets and scenery. 4. Traditional swings and other standard playground equipment accessory to detached one and two-family dwellings, as determined by the Building Official, but they may be subject to Zoning permits. 14 5. Retractable awnings supported by an exterior wall and do not require additional support of Groups R-3 and U occupancies, but they may be subject to Zoning permits. 6. Non-fixed and movable fixtures, cases, racks, and counters not over 5 feet 9 inches (1753 mm) in height. Electrical: Repairs and maintenance: Minor repair work, including the replacement of lamps or the connection of approved portable electrical equipment to approved permanently installed receptacles. Radio and television transmitting stations: The provisions of this code shall not apply to electrical equipment used for radio and television transmissions, but do apply to equipment and wiring for a power supply and the installations of towers and antennas. Temporary testing systems: A permit shall not be required for the installation of any temporary system required for the testing or servicing of electrical equipment or apparatus. Gas: 1. Portable heating appliance. 2. Replacement of any minor part that does not alter approval of equipment or make such equipment unsafe. Mechanical: 1. Portable heating appliance. 2. Portable ventilation equipment. 3. Portable cooling unit. 4. Steam, hot or chilled water piping within any heating or cooling equipment regulated by this code. 5. Replacement of any part that does not alter its approval or make it unsafe. 6. Portable evaporative cooler. 7. Self-contained refrigeration system containing 10 pounds (5 kg) or less of refrigerant and actuated by motors of 1 horsepower (746 W) or less. 15 8. The installation, replacement, removal or metering of any electrical load management control device where installed by a utility service provider. Plumbing: 1. The stopping of leaks in drains, water, soil, waste or vent pipe, provided, however, that if any concealed trap, drain pipe, water, soil, waste or vent pipe becomes defective and it becomes necessary to remove and replace the same with new material, such work shall be considered as new work and a permit shall be obtained and inspection made as provided in this code. 2. The clearing of stoppages or the repairing of leaks in pipes, valves or fixtures and the removal and reinstallation of water closets, provided such repairs do not involve or require the replacement or rearrangement of valves, pipes or fixtures. 3. The replacement of common household plumbing fixtures to existing supply lines and sanitary connections in 1&2 Family Dwellings. This does not include water heaters, bathtubs and showers. 105.2.1 Emergency repairs. Where equipment replacements and repairs must be performed in an emergency situation, the permit application shall be submitted within the next working business day to the Building Official. Notification shall be given to the Building Official, including the work address, nature of emergency, and scope of work immediately, or by the next business day. 105.2.2. Minor repairs. Ordinary minor repairs may be made with the approval of the Building Official without a permit, provided the repairs shall not include the cutting away of any wall, partition or portion thereof, the removal or cutting of any structural beam or load-bearing support, or the removal or change of any required means of egress, or rearrangement of parts of a structure affecting the egress requirements; nor shall ordinary repairs include addition to, alteration of, replacement or relocation of any standpipe, water supply, sewer, drainage, drain leader, gas, soil, waste, vent or similar piping, electric wiring systems or mechanical equipment or other work affecting public health or general safety, and such repairs shall not violate any of the provisions of the technical codes. 105.2.3 Public service agencies. A permit shall not be required for the installation, alteration or repair of generation, transmission, distribution or metering or other related equipment that is under the ownership and control of public service agencies by established right. 105.3 Application for permit. To obtain a permit, the applicant shall first file an application therefore in writing on a form furnished by the Department of Building Safety for that purpose. 16 Permit application forms shall be in the format prescribed by a local administrative board, if applicable, and must comply with the requirements of Section 713.135(5) and (6), Florida Statutes. Each application shall be inscribed with the date of application, and the code in effect as of that date. For a building permit for which an application is submitted prior to the effective date of the Florida Building Code, the state minimum building code in effect in the permitting jurisdiction on the date of the application governs the permitted work for the life of the permit and any extension granted to the permit. Effective October 1, 2017, a local enforcement agency shall post each type of building permit application on its website. Completed applications must be able to be submitted electronically to the appropriate Department of Building Safety. Accepted methods of electronic submission include, but are not limited to, e-mail submission of applications in portable document format or submission of applications through an electronic fill-in form available on the Department of Building Safety's website or through a third-party submission management software. Payments, attachments, or drawings required as part of the permit application may be submitted in person in a non-electronic format, at the discretion of the Building Official. 105.3.1 Action on application. The Building Official shall examine or cause to be examined applications for permits and amendments thereto within a reasonable time after filing. If the application or the construction documents do not conform to the requirements of pertinent laws, the Building Official shall reject such application in writing, stating the reasons therefore. If the Building Official is satisfied that the proposed work conforms to the requirements of this code and laws and ordinances applicable thereto, the Building Official shall issue a permit therefore as soon as practicable. When authorized through contractual agreement with a school board, in acting on applications for permits, the Building Official shall give first priority to any applications for the construction of, or addition or renovation to, any school or educational facility. 105.3.1.1 If a state university, Florida college or public school district elects to use a local government's code enforcement offices, fees charged by counties and municipalities for enforcement of the Florida Building Code on buildings, structures, and facilities of state universities, state colleges, and public school districts shall not be more than the actual labor and administrative costs incurred for plans review and inspections to ensure compliance with the code. 105.3.1.2 No permit may be issued for any building construction, erection, alteration, modification, repair, or addition unless the applicant for such permit provides to the enforcing agency which issues the permit any of the following documents which apply to the construction for which the permit is to be issued and which shall be prepared by or under the direction of an engineer registered under Chapter 471, Florida Statutes: 17 1. Plumbing documents for any new building or addition which requires a plumbing system with more than 250 fixture units or which costs more than $125,000. 2. Fire sprinkler documents for any new building or addition, which includes a fire sprinkler system, which contains 50 or more sprinkler heads. Personnel as authorized by chapter 633 Florida Statutes, may design a new fire protection system of 49 or fewer sprinklers; and may design the alteration of an existing fire sprinkler system if the alteration consists of the relocation, addition or deletion of 49 or fewer sprinklers, notwithstanding the size of the existing fire sprinkler system. 3. Heating, ventilation, and air-conditioning documents for any new building or addition, which requires more than a 15-ton-per-system capacity which is designed to accommodate 100 or more persons or for which the system costs more than $125,000. This paragraph does not include any document for the replacement or repair of an existing system in which the work does not require altering a structural part of the building or for work on a residential one, two, three or four-family structure. An air-conditioning system may be designed by an installing air-conditioning contractor certified under Chapter 489, Florida Statutes, to serve any building or addition which is designed to accommodate fewer than 100 persons and requires an air-conditioning system with a value of $125,000 or less; and when a 15-ton- per system or less is designed for a singular space of a building and each 15-ton system or less has an independent duct system. Systems not complying with the above require design documents that are to be sealed by a professional engineer. Example 1: When a space has two 10-ton systems with each having an independent duct system, the contractor may design these two systems since each unit (system) is less than 15 tons. Example 2: Consider a small single-story office building which consists of six individual offices where each office has a single three-ton package air conditioning heat pump. The six heat pumps are connected to a single water cooling tower. The cost of the entire heating, ventilation and air-conditioning work is $47,000 and the office building accommodates fewer than 100 persons. Because the six mechanical units are connected to a common water tower this is considered to be an 18-ton system. NOTE: It was further clarified by the Commission that the limiting criteria of 100 persons and $125,000 apply to the building occupancy load and the cost for the total air-conditioning system of the building. 4. Any specialized mechanical, electrical, or plumbing document for any new building or addition which includes a medical gas, oxygen, steam, vacuum, toxic air filtration, halon, or fire detection and alarm system which costs more than $5,000. 18 5. Electrical documents. See Florida Statutes 471 .003(2)(h). Any electrical or plumbing or air conditioning and refrigeration system meeting the following thresholds are required to be designed by a Florida Registered Engineer. Any system which: 1. Requires an electrical or plumbing or air-conditioning and refrigeration system with a value greater than $125,000-1 and 2. a. Requires an aggregate service capacity of greater than 600 amperes (240 volts) on a residential electrical system or greater than 800 amperes (240 volts) on a commercial or industrial electrical system; b. Requires a plumbing system with more than 250 fixture units; or c. Requires a heating, ventilation, and air-conditioning system which exceeds a 15-ton-per-system capacity, or if the project is designed to accommodate more than 100 persons. Documents requiring an engineer seal by this part shall not be valid unless a professional engineer who possess a valid certificate of registration has signed, dated, and stamped such document as provided in Section 471.025, Florida Statutes. 6. All public swimming pools and public bathing places defined by and regulated under Chapter 514, Florida Statutes. 105.3.2 Time limitation of application. An application for a permit for any proposed work shall be deemed to have been abandoned becoming null and void 180 days after the date of filing, or for any 180 day period of abandonment or suspension during the application process, unless such application has been pursued in good faith or a permit has been issued; except that the Building Official is authorized to grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing prior to the abandonment date, with justifiable cause demonstrated. Abandoned applications shall be subject to destruction in accordance with state law. The fee for renewal, re-issuance, and extension of a permit application shall be set forth by the Village of Tequesta Village Council. There may be fees or requirements from other government agencies for permit application extensions and renewals. 105.3.3 An enforcing authority may not issue a building permit for any building construction, erection, alteration, modification, repair or addition unless the permit either includes on its face or there is attached to the permit the following statement: "NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, such as the requirement for Home or Property Owners Association approval, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies." 105.3.4 A building permit for a single-family residential dwelling must be issued within 30 working days of application therefore unless unusual circumstances require a 19 longer time for processing the application or unless the permit application fails to satisfy the Florida Building Code or the enforcing agency's laws or ordinances. 105.3.5 Identification of minimum premium policy. Except as otherwise provided in Chapter 440, Florida Statutes, Workers' Compensation, every employer shall, as a condition to receiving a building permit, show proof that it has secured compensation for its employees as provided in Section 440.10 and 440.38, Florida Statutes. 105.3.6 Asbestos removal contractor exemption. Refer to Section 105.9 herein- below for additional requirements. A licensed asbestos removal contractor is not required when moving, removal or disposal of asbestos-containing materials on a residential building where the owner occupies the building, the building is not for sale or lease, and the work is performed according to the owner-builder limitations provided in this paragraph. To qualify for exemption under this paragraph, an owner must personally appear and sign the building permit application. The permitting agency shall provide the person with a disclosure statement in substantially the following form: Disclosure Statement: State law requires asbestos abatement to be done by licensed contractors. You have applied for a permit under an exemption to that law. The exemption allows you, as the owner of your property, to act as your own asbestos abatement contractor even though you do not have a license. You must supervise the construction yourself. You may move, remove or dispose of asbestos-containing materials on a residential building where you occupy the building and the building is not for sale or lease, or the building is a farm outbuilding on your property. If you sell or lease such building within 1 year after the asbestos abatement is complete, the law will presume that you intended to sell or lease the property at the time the work was done, which is a violation of this exemption. You may not hire an unlicensed person as your contractor. Your work must be done according to all local, state and federal laws and regulations, which apply to asbestos abatement projects. It is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. 105.3.7 Applicable Code for Manufactured Buildings. Manufacturers should be permitted to complete all buildings designed and approved prior to the effective date of a new code edition, provided a clear signed contract is in place. The contract shall provide specific data mirroring that required by an application for permit, specifically, without limitation, date of execution, building owner or dealer, and anticipated date of completion. However, the construction activity must commence within 6 months of the contract's execution. The contract is subject to verification by the Department of Business and Professional Regulation. 105.3.8 Contract. The Village of Tequesta shall not require a contract between a builder and an owner for the issuance of a building permit or as a requirement for the submission of a building permit application. 20 105.3.9 Public right of way. A permit shall not be given by the Building Official for the construction of any building, or for the alteration of any building where said building is to be changed and such change will affect the exterior walls, bays, balconies, or other appendages or projections fronting on any street, alley or public lane, or for the placing on any lot or premises of any building or structure removed from another lot or premises, unless the applicant has received a right of way permit from the authority having jurisdiction over the street, alley or public lane. 105.4 Conditions of the permit. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of any other federal, state and local laws, ordinances, codes and regulations. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of any other federal, state and local laws, ordinances, codes and regulations shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. The Building Official is also authorized to prevent occupancy or use of a structure where in violation of this code or of any other ordinances of this jurisdiction or of any other federal, state and local laws, ordinances, codes and regulations. 105.4.1 Permit intent. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter or set aside any of the provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of this code. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months after its issuance, or if the work authorized by such permit is suspended or abandoned for a period of six months after the time the work is commenced. 105.4.1.1 If work has commenced and the permit is revoked, becomes null and void, or expires because of lack of progress or abandonment, a new permit covering the proposed construction shall be obtained before proceeding with the work. 105.4.1.2 If a new permit, or revalidation (renewal) of the original permit, is not obtained within 180 days from the date the initial permit became null and void, the Building Official is authorized to require that any work which has been commenced or completed be removed from the building site. Alternately, a new permit may be issued on application, providing the work in place and required to complete the structure meets all applicable regulations in effect at the time the initial permit became null and void and any regulations which may have become effective between the date of expiration and the date of issuance of the new permit. 105.4.1.3 Work shall be considered to be in active progress when the permit has received an approved inspection within 180 days. This provision shall not be applicable in case of civil commotion or strike or when the building work is halted due directly to judicial injunction, order or similar process, or due to action by an 21 environmental or archeological agency having jurisdiction. The Building Official is authorized to grant, in writing, one or more extensions of time, for periods not more than 3 months each. The extension shall be requested in writing and justifiable cause demonstrated, prior to expiration. 105.4.1.4 The fee for renewal, reissuance and extension of a permit shall be set forth by the administrative authority. There may be fees or requirements from other government agencies for permit extensions and renewals. 105.4.1.5 Any building permit work that has not received a certificate of occupancy or certificate of completion within two years from the date of original issuance shall be considered expired. If a new building permit is not obtained in accordance with section 105.4.1.2 herein, within 30 days of the expiration of the expired building permit, the construction shall be subject to unsafe structure abatement proceedings. 105.4.2 Additional options for closing a permit. Pursuant to Section 553.79(15), Florida Statutes, a property owner, regardless of whether the property owner is the one listed on the application for the building permit, may close a building permit by complying with the following requirements- 1. The property owner may retain the original contractor listed on the permit or hire a different contractor appropriately licensed in this state to perform the work necessary to satisfy the conditions of the permit and to obtain any necessary inspection in order to close the permit. If a contractor other than the original contractor listed on the permit is hired by the property owner to close the permit, such contractor is not liable for any defects in the work performed by the original contractor and is only liable for the work that he or she performs. 2. The property owner may assume the role of an owner-builder, in accordance with Sections 489.103(7) and 489.503(6), Florida Statutes. 3. If a building permit is expired and its requirements have been substantially completed as determined by the local enforcement agency, the permit may be closed without having to obtain a new building permit, and the work required to close the permit may be done pursuant to the building code in effect at the time the Village of Tequesta received the application for the permit, unless the contractor has sought and received approval from the Village of Tequesta for an alternative material, design or method of construction. 4. The Village of Tequesta may close a building permit 6 years after the issuance of the permit, even in the absence of a final inspection, if the Village of Tequesta determines that no apparent safety hazard exists. For purposes of this section, the term "close" means that the requirements of the permit have been satisfied. 22 105.5 Expiration. Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Building Official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated as determined by the Building Official. 105.6 Denial or revocation. Whenever a permit required under this section is denied or revoked because the plan, or the construction, erection, alteration, modification, repair, or demolition of a building, is found by the Village of Tequesta to be not in compliance with the Florida Building Code, the Village of Tequesta shall identify the specific plan or project features that do not comply with the applicable codes, identify the specific code chapters and sections upon which the finding is based, and provide this information to the permit applicant. If the local building code administrator or inspector finds that the plans are not in compliance with the Florida Building Code, the local building code administrator or inspector shall identify the specific plan features that do not comply with the applicable codes, identify the specific code chapters and sections upon which the finding is based, and provide this information to the Village of Tequesta. The Village of Tequesta shall provide this information to the permit applicant. Pursuant to Section 553.79(16), Florida Statutes, the Village of Tequesta may not deny issuance of a building permit to; issue a notice of violation to; or fine, penalize sanction or assess fees against an arm's-length purchaser of a property for value solely because a building permit applied for by a previous owner of the property was not closed. The Village of Tequesta shall maintain all rights and remedies against the property owner and contractor listed on the permit. Pursuant to Section 553.79(16), Florida Statutes, the Village of Tequesta may not deny issuance of a building permit to a contractor solely because the contractor is listed on other building permits that were not closed. 105.6.1 Misrepresentation of application. The Building Official may revoke a permit or approval, issued under the provisions of this code, when there has been any false statement or misrepresentation as to the material fact in the application or plans on which the permit or approval was based. 105.6.2 Violation of code provisions. The Building Official may require correction or revoke the permit upon determination by the Building Official that the construction, erection, alteration, repair, moving, demolition, installation, or replacement of the building, structure, electrical, gas, mechanical or plumbing systems for which the permit was issued is in violation of, or not in conformity with, the provisions of this code or the Village of Tequesta Code of Ordinances. 105.7 Placement of permit. The building permit or a copy shall be kept on the site of the work until the completion of the project. 23 105.8 Notice of commencement. In accordance with Section 713.135, Florida Statutes, when any person applies for a building permit, the authority issuing such permit shall print on the face of each permit card in no less than 14-point, capitalized, boldfaced type: "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." 105.9 Asbestos. The Village of Tequesta shall require each building permit for the demolition or renovation of an existing structure to contain an asbestos notification statement which indicates the owner's or operator's responsibility to comply with the provisions of Section 469.003, Florida Statutes, and to notify the Department of Environmental Protection of his or her intentions to remove asbestos, when applicable, in accordance with state and federal law. Refer to Section 105.3.6 "Asbestos Removal Contractor Exemption" of this code for additional requirements. 105.10 Certificate of protective treatment for prevention of termites. A weather- resistant job-site posting board shall be provided to receive duplicate treatment certificates as each required protective treatment is completed, providing a copy for the person the permit is issued to and another copy for the building permit files. The treatment certificate shall provide the product used, identity of the applicator, time and date of the treatment, site location, area treated, chemical used, percent concentration and number of gallons used, to establish a verifiable record of protective treatment. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall be completed prior to final building approval. For a bait system, see Section 1816.1.7 of the Florida Building Code for contract document requirements. 105.11 Notice of termite protection. A permanent sign which identifies the termite treatment provider and need for reinspection and treatment contract renewal shall be provided. The sign shall be posted near the water heater or electric panel. 105.12 Work starting before permit issuance. Upon written request and approval of the Building Official, the scope of work delineated in the building permit application and plan may be started prior to the final approval and issuance of the permit, provided any work completed is entirely at risk of the permit applicant and the work does not proceed past the first required inspection. 105.13 Phased permit approval. After submittal of the appropriate construction documents, the Building Official is authorized to issue a permit for the construction of foundations or any other part of a building or structure before the construction documents for the whole building or structure have been submitted. The holder of such permit for the foundation or other parts of a building or structure shall proceed at the holder's own risk with the building operation and without assurance that a permit for the entire structure will be granted. Corrections may be required to meet the requirements of the technical codes. 24 105.14 Permit issued on basis of an affidavit. The Building Official may accept a sworn affidavit from a registered architect or engineer stating that the plans submitted conform to the technical codes. For buildings and structures, the affidavit shall state that the plans conform to the laws as to egress, type of construction and general arrangement and, if accompanied by drawings, show the structural design and that the plans and design conform to the requirements of the technical codes as to strength, stresses, strains, loads and stability. Whenever a permit is issued in reliance upon an affidavit or whenever the work to be covered by a permit involves installation under conditions, which, in the opinion of the Building Official, are hazardous or complex, the Building Official shall require that the architect or engineer who signed the affidavit or prepared the drawings or computations shall supervise such work. In addition, they shall be responsible for conformity to the permit, provide copies of inspection reports as inspections are performed, and upon completion make and file with the Building Official written affidavit that the work has been done in conformity to the reviewed plans and with the structural provisions of the technical codes. In the event such architect or engineer is not available, the owner shall employ in his stead a competent person or agency whose qualifications are reviewed by the Building Official. The Building Official shall ensure that any person conducting plans review is qualified as a plans examiner under Part XII of Chapter 468, Florida Statutes, and that any person conducting inspections is qualified as a building inspector under Part I II of Chapter 468, Florida Statutes. Nothing aforesaid shall preclude plan review or inspections by the Building Official (See also Section 107.6). Exception: Permits issued on basis of an affidavit shall not extend to the flood load and flood resistance requirements of the Florida Building Code and the Building Official shall review and inspect those requirements. 105.15 Opening protection. When any activity requiring a building permit that is applied for on or after July 1, 2008, and for which the estimated cost is $50,000 or more for a site built single-family detached residential structure that is located in the wind borne debris region as defined in this Code and that has an insured value of $750,000 or more, or, if the site built single-family detached residential structure is uninsured or for which documentation of insured value is not presented, has a just valuation for the structure for purposes of ad valorem taxation of $750,000 or more; opening protections as required within this Code or Florida Building Code, Residential for new construction shall be provided. Exception: Where defined wind-borne debris regions have not changed, single family detached residential structures permitted subject to the Florida Building Code are not required to comply with this section. 105.16 Inspection of existing residential building not impacted by construction. (a)A Village of Tequesta, and any local building code administrator, inspector, or other official or entity, may not require as a condition of issuance of a one- or two-family residential building permit the inspection of any portion of a building, structure, or real property that is not directly impacted by the construction, erection, alteration, 25 modification, repair, or demolition of the building, structure, or real property for which the permit is sought. (b) This subsection does not apply to a building permit sought for: 1. A substantial improvement as defined in Section 161.54, Florida Statutes or as defined in the Florida Building Code. 2. A change of occupancy as defined in the Florida Building Code. 3. A conversion from residential to nonresidential or mixed use pursuant to Section 553.507(2)(a), Florida Statutes or as defined in the Florida Building Code. 4. A historic building as defined in the Florida Building Code. (c) This subsection does not prohibit a Village of Tequesta, or any local building code administrator, inspector, or other official or entity, from: 1. Citing any violation inadvertently observed in plain view during the ordinary course of an inspection conducted in accordance with the prohibition in paragraph (a). 2. Inspecting a physically nonadjacent portion of a building, structure, or real property that is directly impacted by the construction, erection, alteration, modification, repair, or demolition of the building, structure, or real property for which the permit is sought in accordance with the prohibition in paragraph (a). 3. Inspecting any portion of a building, structure, or real property for which the owner or other person having control of the building, structure, or real property has voluntarily consented to the inspection of that portion of the building, structure, or real property in accordance with the prohibition in paragraph (a). 4. Inspecting any portion of a building, structure, or real property pursuant to an inspection warrant issued in accordance with Sections 933.20-933.30, Florida Statutes. 105.17 Streamlined low-voltage alarm system installation permitting. (1)As used in this section, the term: (a) "Contractor" means a person who is qualified to engage in the business of electrical or alarm system contracting pursuant to a certificate or registration issued by the department under part II of chapter 489, Florida Statutes. (b) "Low-voltage alarm system project" means a project related to the installation, maintenance, inspection, replacement, or service of a new or existing alarm system, as defined in Section 489.505, Florida Statutes, including video cameras and closed-circuit television systems used to signal or detect a burglary, fire, robbery, or medical emergency, that is hardwired and operating at low voltage, as defined in the National Electrical Code Standard 70, current edition, or a new or existing low- voltage electric fence. The term also includes ancillary components or equipment 26 attached to a low-voltage alarm system, or low-voltage electric fence, including, but not limited to, home-automation equipment, thermostats, closed-circuit television systems, access controls, battery recharging devices, and video cameras. (c) "Low-voltage electric fence" means an alarm system, as defined in s. 489.505, that consists of a fence structure and an energizer powered by a commercial storage battery not exceeding 12 volts which produces an electric charge upon contact with the fence structure. (d) "Wireless alarm system" means a burglar alarm system or smoke detector that is not hardwired (2) Notwithstanding any provision of this Code, this section applies to all low-voltage alarm system projects for which a permit is required by a local enforcement agency. However, a permit is not required to install, maintain, inspect, replace, or service a wireless alarm system, including any ancillary components or equipment attached to the system. 1. A low-voltage electric fence must meet all of the following requirements to be permitted as a low-voltage alarm system project and no further permit shall be required for the low-voltage alarm system project other than as provided in this section: (a) The electric charge produced by the fence upon contact must not exceed energizer characteristics set forth in paragraph 22.108 and depicted in Figure 102 of International Electrotechnical Commission Standard No. 60335-2-76, Current Edition. (b) A nonelectric fence or wall must completely enclose the low-voltage electric fence. The low- voltage electric fence may be up to 2 feet higher than the perimeter nonelectric fence or wall. (c) The low-voltage electric fence must be identified using warning signs attached to the fence at intervals of not more than 60 feet. (d) The low-voltage electric fence shall not be installed in an area zoned exclusively for single- family or multi-family residential use. (e) The low-voltage electric fence shall not enclose the portions of a property which are used for residential purposes. (4) This section does not apply to the installation or replacement of a fire alarm if a plan review is required. (5) The Village of Tequesta shall make uniform basic permit labels available for purchase by a contractor to be used for the installation or replacement of a new or existing alarm system at a cost as indicated in Section 553.793, Florida Statutes. The Village of Tequesta may not require the payment of any additional fees, charges, or expenses associated with the installation or replacement of a new or existing alarm. 27 (a) The Village of Tequesta may not require a contractor, as a condition of purchasing a label, to submit information other than identification information of the licensee and proof of registration or certification as a contractor. (b)A label is valid for 1 year after the date of purchase and may only be used within the jurisdiction of the local enforcement agency that issued the label. A contractor may purchase labels in bulk for one or more unspecified current or future projects. (6)A contractor shall post an unused uniform basic permit label in a conspicuous place on the premises of the low-voltage alarm system project site before commencing work on the project. (7) A contractor is not required to notify the local enforcement agency before commencing work on a low-voltage alarm system project. However, a contractor must submit a Uniform Notice of a Low-Voltage Alarm System Project as provided under subsection (7) to the local enforcement agency within 14 days after completing the project. A local enforcement agency may take disciplinary action against a contractor who fails to timely submit a Uniform Notice of a Low-Voltage Alarm System Project. (8) The Uniform Notice of a Low-Voltage Alarm System Project may be submitted electronically or by facsimile if all submissions are signed by the owner, tenant, contractor, or authorized representative of such persons. The Uniform Notice of a Low- Voltage Alarm System Project shall be in the format prescribed by the local enforcement agency and must comply with the requirements of Section 553.793(7), Florida Statutes. (9) The Village of Tequesta may coordinate directly with the owner or customer to inspect a low-voltage alarm system project may be inspected by the local enforcement agency to ensure compliance with applicable codes and standards. If a low-voltage alarm system project fails an inspection, the contractor must take corrective action as necessary to pass inspection. (10) The Village of Tequesta shall not adopt or maintain in effect any ordinance or rule regarding a low-voltage alarm system project that is inconsistent with this section. (11)A uniform basic permit label shall not be required for the subsequent maintenance, inspection, or service of an alarm system that was permitted in accordance with this section. The provisions of this act are not intended to impose new or additional licensure requirements on persons licensed in accordance with the applicable provisions of chapter 489, Florida Statutes. SECTION 106 FLOOR AND ROOF DESIGN LOADS 106.1 Live loads posted. Where the live loads for which each floor or portion thereof of a commercial or industrial building is or has been designed to exceed 50 psf(2.40 kN/m2), such design live loads shall be conspicuously posted by the owner or the owner's 28 authorized agent in that part of each story in which they apply, using durable signs. It shall be unlawful to remove or deface such notices 106.2 Issuance of certificate of occupancy. A certificate of occupancy required by Section 111 shall not be issued until the floor load signs, required by Section 106.1, have been installed. 106.3 Restrictions on loading. It shall be unlawful to place, or cause or permit to be placed, on any floor or roof of a building, structure or portion thereof, a load greater than is permitted by this code. SECTION 107 SUBMITTAL DOCUMENTS 107.1 General. Submittal documents consisting of construction documents, statement of special inspections, geotechnical report and other data shall be submitted in two or more sets with each permit application in accordance with Florida Statute 553.79. The construction documents shall be prepared by a registered design professional where required by Chapter 471, Florida Statutes & 61 G15 Florida Administrative Code or Chapter 481, Florida Statutes & 61 G1 Florida Administrative Code. Where special conditions exist, the Building Official is authorized to require additional construction documents to be prepared by a registered design professional. Electronic media documents shall be submitted when required by the Building Official, in a format acceptable to the Building Official, and may require only one set of submittals. Exception: The Building Official is authorized to waive the submission of construction documents and other data not required to be prepared by a registered design professional if it is found that the nature of the work applied for is such that review of construction documents is not necessary to obtain compliance with this code. If the design professional is an architect, interior designer, or engineer legally registered under the laws of this state regulating the practice of architecture or interior design as provided for in Chapter 481, Florida Statutes, Part I, or landscape architecture as provided for in Chapter 481, Florida Statutes, Part 11, or engineering as provided for in Chapter 471, Florida Statutes, then he or she shall affix his or her official seal to said drawings, specifications and accompanying data, as required by Florida Statutes. 107.2 Construction documents. Construction documents shall be in accordance with Sections 107.2.1 through 107.2.6. 107.2.1 Information on construction documents. Construction documents shall be dimensioned and drawn upon suitable material. Electronic media documents are permitted to be submitted when approved by the Building Official. Construction documents shall be of sufficient clarity to indicate the location, nature and extent of the work proposed and show in detail that it will conform to the provisions of this code and relevant laws, ordinances, rules and regulations, as 29 determined by the Building Official. Such drawings and specifications shall contain information, in the form of notes or otherwise, as to the quality of materials, where quality is essential to conformity with the technical codes. Such information shall be specific, and the technical codes shall not be cited as a whole or in part, nor shall the term "legal" or its equivalent be used as a substitute for specific information. All information, drawings, specifications and accompanying data shall bear the name and signature of the person responsible for the design. 107.2.1.1 For roof assemblies required by the code, the construction documents shall illustrate, describe and delineate the type of roofing system, materials, fastening requirements, flashing requirements and wind resistance rating that are required to be installed. Product evaluation and installation shall indicate compliance with the wind criteria required for the specific site or a statement by an architect or engineer certifying suitability for the specific site must be submitted with the construction documents. 107.2.1.2 Additional data. The Building Official may require details, computations, stress diagrams, and other data necessary to describe the construction or installation and the basis of calculations. All drawings, specifications and accompanying data required by the Building Official to be prepared by an architect or engineer shall be affixed with their official seal, signature and date as state law requires. 107.2.1.3 Quality of building plans. Building plans shall be drawn to a minimum 1/8 inch scale upon substantial paper, cloth or other acceptable medium. The Building Official may establish, through Departmental policy, other standards for plans and specifications, including electronic format, in order to provide conformity to its electronic permit review and record retention program. This policy may include such things as minimum size, shape, contrast, clarity, or other items related to records management. Electronic media must be compatible with the archive requirements of Florida Statutes. 107.2.2 Fire protection system shop drawings. Shop drawings for the fire protection system(s) shall be submitted to indicate conformance to this code and the construction documents and shall be approved prior to the start of system installation. Shop drawings shall contain all information as required by the referenced installation standards in Chapter 9 of the Florida Building Code. 107.2.3 Means of egress. The construction documents shall show in sufficient detail the location, construction, size and character of all portions of the means of egress including the path of the exit discharge to the public way in compliance with the provisions of this code. In other than occupancies in Groups R-2, R-3, and 1-1, the construction documents shall designate the number of occupants to be accommodated on every floor, and in all rooms and spaces. 30 107.2.4 Exterior wall envelope. Construction documents for all buildings shall describe the exterior wall envelope insufficient detail to determine compliance with this code. The construction documents shall provide details of the exterior wall envelope as required, including flashing, intersections with dissimilar materials, corners, end details, control joints, intersections at roof, eaves or parapets, means of drainage, water-resistive membrane and details around openings. The construction documents shall include manufacturer's installation instructions that provide supporting documentation that the proposed penetration and opening details described in the construction documents maintain the weather resistance of the exterior wall envelope. The supporting documentation shall fully describe the exterior wall system which was tested, where applicable, as well as the test procedure used. 107.2.5 Exterior balcony and elevated walking surfaces. Where balcony or other elevated walking surfaces are exposed to water from direct or blowing rain, snow or irrigation, and the structural framing is protected by an impervious moisture barrier the construction documents shall include details for all element of the impervious moisture barrier system. The construction documents shall include manufacturer's installation instructions. (CA7834) 107.2.6 Site plan. The construction documents submitted with the application for permit shall be accompanied by a site plan showing to scale the size and location of new construction and existing structures on the site, distances from lot lines, the established street grades and the proposed finished grades and, as applicable, flood hazard areas, floodways, and design flood elevations; and it shall be drawn in accordance with an accurate boundary line survey. In the case of demolition, the site plan shall show construction to be demolished and the location and size of existing structures and construction that are to remain on the site or plot. The Building Official is authorized to waive or modify the requirement for a site plan when the application for permit is for alteration or repair or when otherwise warranted. 107.2.6.1 Design flood elevations. Where design flood elevations are not specified, they shall be established in accordance with Section 1612.3.1. Design flood elevations shall be uniformly specified utilizing the currently effective NAVD 88. 107.2.6.2 For the purpose of inspection and record retention, site plans for a building may be maintained in the form of an electronic copy at the worksite. These plans must be open to inspection by the Building Official or a duly authorized representative, as required by the Florida Building Code. 107.2.7 Structural information. The construction documents shall provide the information specified in Section 1603. 107.3 Examination of documents. The Building Official shall examine or cause to be examined the accompanying submittal documents and shall ascertain by such 31 examinations whether the construction indicated and described is in accordance with the requirements of this code and other pertinent laws or ordinances. Exceptions: 1. Building plans approved pursuant to Section 553.77(5), Florida Statutes, and state-approved manufactured buildings are exempt from local codes Village of Tequesta plan reviews except for provisions of the code relating to erection, assembly or construction at the site. Erection, assembly and construction at the site are subject to local permitting and inspections. Photocopies of plans approved according to FAC 61-41.009, Florida Administrative Code, shall be sufficient for Village of Tequesta permit application documents of record for the modular building portion of the permitted project. 2. Industrial construction on sites where design, construction and fire safety are supervised by appropriately licensed design and inspection professionals and which contain adequate in-house fire departments and rescue squads is exempt, subject to approval by the Building Official, from review of plans and inspections, providing the appropriate licensed design and inspection professionals certify that applicable codes and standards have been met and supply appropriate approved drawings to local building and fire-safety inspectors. 107.3.1 Approval of construction documents. When the Building Official issues a permit, the construction document shall be approved, in writing or by stamp, as "Reviewed for Code Compliance." One set of construction documents so reviewed shall be retained by the Building Official. The other set shall be returned to the applicant, shall be kept at the site of work and shall be open to inspection by the Building Official or a duly authorized representative. 107.3.2 Previous approvals. This code shall not require changes in the construction documents, construction or designated occupancy of a structure for which a lawful permit has been heretofore issued or otherwise lawfully authorized, and the construction of which has been pursued in good faith within 180 days after the effective date of this code and has not been abandoned. 107.3.3 Phased approval. The Building Official is authorized to issue a permit for the construction of foundations or any other part of a building or structure before the construction documents for the whole building or structure have been submitted, provided that adequate information and detailed statements have been filed complying with pertinent requirements of this code. The holder of such permit for the foundation or other parts of a building or structure shall proceed at the holder's own risk with the building operation and without assurance that a permit for the entire structure will be granted. 107.3.4 Design professional in responsible charge. Where it is required that documents be prepared by a registered design professional, the Building Official shall 32 be authorized to require the owner or the owner's authorized agent to engage and designate on the building permit application a registered design professional who shall act as the registered design professional in responsible charge. If the circumstances require, the owner or the owner's authorized agent shall designate a successor registered design professional in responsible charge who shall perform the duties required of the original registered design professional in responsible charge. The Building Official shall be notified in writing by the owner or the owner's authorized agent if the registered design professional in responsible charge is changed or is unable to continue to perform the duties. Successor registered design professional in responsible charge licensed under Chapter 471 Florida Statutes shall comply with Section 471.025(4) Florida Statute and the procedure set forth in 61G15-27.001 Florida Administrative Code; or licensed under Chapter 481 Florida Statutes shall comply with Section 481.221(6) Florida Statute and the procedure set forth in 61 G1- 18.002 Florida Administrative Code. The registered design professional in responsible charge shall be responsible for reviewing and coordinating submittal documents prepared by others, including phased and deferred submittal items, for compatibility with the design of the building. Those products which are regulated by FAC Rule 61 G20 shall be reviewed and approved in writing by the designer of record prior to submittal for jurisdictional approval. 107.3.4.1 Deferred submittals. For the purposes of this section, deferred submittals are defined as those portions of the design that are not submitted at the time of the application and that are to be submitted to the Building Official. Deferral of any submittal items shall have the prior approval of the Building Official. The registered design professional in responsible charge shall list the deferred submittals on the construction documents for review by the Building Official. Documents for deferred submittal items shall be submitted to the registered design professional in responsible charge who shall review them and forward them to the Building Official with a notation indicating that the deferred submittal documents have been reviewed and found to be in general conformance to the design of the building. The deferred submittal items shall not be installed until the deferred submittal documents have been approved by the Building Official. 107.3.4.2 Certifications by contractors authorized under the provisions of Section 489.115(4)(b), Florida Statutes, shall be considered equivalent to sealed plans and specifications by a person licensed under Chapter 471, Florida Statutes, or Chapter 481 Florida Statutes, by local enforcement agencies for plans review for permitting purposes relating to compliance with the wind-resistance provisions of the code or alternate methodologies approved by the Florida Building Commission for one- and two-family dwellings. Local enforcement agencies may rely upon such certification by contractors that the plans and specifications submitted conform to the requirements of the code for wind resistance. Upon good cause shown, local government code enforcement agencies may accept or reject plans sealed by persons licensed under Chapters 471, 481 or 489, Florida Statutes. 33 107.3.5 Minimum plan review criteria for buildings. The examination of the documents by the Building Official shall include the following minimum criteria and documents: a floor plan; site plan; foundation plan, floor/roof framing plan or truss layout; all fenestration and building envelope penetrations, flashing; and rough opening dimensions; and all exterior elevations: Commercial Buildings: Building 1. Site requirements: Parking Fire access Vehicle loading Driving/turning radius Fire hydrant/water supply/post indicator valve (PIV) Set back/separation (assumed property lines) Location of specific tanks, water lines and sewer lines Flood hazard areas, flood zones, and design flood elevations 2. Occupancy group and special occupancy requirements shall be determined (with cross check with the energy code submittal). 3. Minimum type of construction shall be determined (see Table 503). 4. Fire-resistant construction requirements shall include the following components: Fire-resistant separations Fire-resistant protection for type of construction Protection of openings and penetrations of rated walls Fire blocking and draftstopping and calculated fire resistance 5. Fire suppression systems shall include: Early warning smoke evacuation systems Schematic fire sprinklers Standpipes Pre-engineered systems Riser diagram 6. Life safety systems shall be determined and shall include the following requirements: Occupant load and egress capacities Early warning Smoke control Stair pressurization Systems schematic 7. Occupancy load/egress requirements shall include: 34 Occupancy load Gross Net Means of egress Exit access Exit Exit discharge Stairs construction/geometry and protection Doors Emergency lighting and exit signs Specific occupancy requirements Construction requirements Horizontal exits/exit passageways 8. Structural requirements shall include: Soil conditions/analysis Termite protection Design loads Wind requirements Building envelope Impact resistant coverings or systems Structural calculations (if required) Foundation Flood requirements in accordance with Section 1612, including lowest floor elevations, enclosures, flood damage-resistant materials Wall systems Floor systems Roof systems Threshold inspection plan Stair systems 9. Materials shall be reviewed and shall at a minimum include the following: Wood Steel Aluminum Concrete Plastic Glass Masonry Gypsum board and plaster Insulating (mechanical) Roofing Deck coatings Insulation Building envelope portions of the Energy Code (including calculation and mandatory requirements) 35 10. Accessibility requirements shall include the following: Site requirements Accessible route Vertical accessibility Toilet and bathing facilities Drinking fountains Equipment Special occupancy requirements Fair housing requirements 11. Interior requirements shall include the following: Interior finishes (flame spread/smoke development) Light and ventilation (including corresponding portion of the energy code) Sanitation 12. Special systems: Elevators Escalators Lifts 13. Swimming pools: Barrier requirements Spas Wading pools 14. Location and installation details. The specific location and installation details of each fire door, fire damper, ceiling damper and smoke damper shall be shown and properly identified on the building plans by the designer. Electrical 1. Electrical: Wiring Services Feeders and branch circuits Overcurrent protection Grounding Wiring methods and materials GFCIs Electrical portions of the Energy Code (including calculation and mandatory requirements) 2. Equipment 3. Special occupancies 4. Emergency systems 5. Communication systems 6. Low voltage 36 7. Load calculations 8. Design flood elevation Plumbing 1. Minimum plumbing facilities 2. Fixture requirements 3. Water supply piping 4. Sanitary drainage 5. Water heaters 6. Vents 7. Roof drainage 8. Back flow prevention 9. Irrigation 10. Location of water supply line 11 . Grease traps 12. Environmental requirements 13. Plumbing riser 14. Design flood elevation 15. Water/plumbing portions of the Energy Code (including calculation and mandatory requirements) Mechanical 1 . Mechanical portions of the energy calculations 2. Exhaust systems: Clothes dryer exhaust Kitchen equipment exhaust Specialty exhaust systems 3. Equipment 4. Equipment location 5. Make-up air 6. Roof-mounted equipment 7. Duct systems 8. Ventilation 9. Combustion air 10. Chimneys, fireplaces and vents 11 . Appliances 12. Boilers 13. Refrigeration 14. Bathroom ventilation 15. Laboratory 16. Design flood elevation 17. Smoke and/or Fire Dampers Gas 1. Gas piping 2. Venting 37 3. Combustion air 4. Chimneys and vents 5. Appliances 6. Type of gas 7. Fireplaces 8. LP tank location 9. Riser diagram/shutoffs 10. Design flood elevation 11. Gas portions of the Energy Code (including calculation and mandatory requirements) Demolition 1. Asbestos removal Residential (one- and two-family): 1. Site requirements: Setback/separation (assumed property lines) Drainage Plan (professionally prepared) Set back/separation (assumed property lines) Location of septic tanks 2. Fire-resistant construction (if required) 3. Fire 4. Smoke detector locations 5. Egress Egress window size and location stairs construction requirements 6. Structural requirements shall include: Wall section from foundation through roof, including assembly and materials, connector tables, wind requirements, and structural calculations (if required) Termite protection Design loads Wind requirements Building envelope Foundation Wall systems Floor systems Roof systems Flood hazard areas, flood zones, design flood elevations, lowest floor elevations, enclosures, equipment, and flood damage-resistant materials 7. Accessibility requirements: show/identify accessible bath 8. Impact resistant coverings or systems 9. Residential Energy Code submittal (including calculation and mandatory requirements) 10. Electrical: Electric service riser with wire sizes, conduit detail and grounding detail 38 Complete load calculations, Panel schedules 11. Mechanical: Equipment and location, Duct systems 12. Plumbing: Plumbing riser 13. Gas: Gas piping Venting Combustion air Chimneys and vents Appliances Type of gas Fireplaces LP tank location Riser diagram/shutoffs 14. Swimming Pools Barrier requirements Spas Wading pools Manufactured buildings/housing — 1. Site requirements Setback/separation (assumed property lines) Location of septic tanks (if applicable) 2. Structural Wind zone Anchoring Blocking 3. Plumbing List potable water source and meter size (if applicable) 4. Mechanical Exhaust systems Clothes dryer exhaust Kitchen equipment exhaust 5. Electrical exterior disconnect location Exemptions. Plans examination by the Building Official shall not be required for the following work: 1. Replacing existing equipment such as mechanical units, water heaters, etc. 2. Reroofs (as determined by local jurisdiction) 3. Minor electrical, plumbing and mechanical repairs 4. Annual maintenance permits 5. Prototype plans 39 Except for local site adaptions, siding, foundations and/or modifications. Except for structures that require waiver. 6. Manufactured buildings plan except for foundations and modifications of buildings on site and as listed above in manufactured buildings/housing. 107.4 Amended construction documents. Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in compliance with the approved construction documents shall be resubmitted for approval as an amended set of construction documents. 107.5 Retention of construction documents. One set of approved construction documents shall be retained by the Building Official for a period of not less than 180 days from date of completion of the permitted work, or as required by state or local laws. 107.6 Affidavits. The Building Official may accept a sworn affidavit from a registered architect or engineer stating that the plans submitted conform to the technical codes. For buildings and structures, the affidavit shall state that the plans conform to the laws as to egress, type of construction and general arrangement and, if accompanied by drawings, show the structural design and that the plans and design conform to the requirements of the technical codes as to strength, stresses, strains, loads and stability. The Building Official may without any examination or inspection accept such affidavit, provided the architect or engineer who made such affidavit agrees to submit to the Building Official copies of inspection reports as inspections are performed and upon completion of the structure, electrical, gas, mechanical or plumbing systems a certification that the structure, electrical, gas, mechanical or plumbing system has been erected in accordance with the requirements of the technical codes. Where the Building Official relies upon such affidavit, the architect or engineer shall assume full responsibility for compliance with all provisions of the technical codes and other pertinent laws or ordinances. The Building Official shall ensure that any person conducting plans review is qualified as a plans examiner under Part XII of Chapter 468, Florida Statutes, and that any person conducting inspections is qualified as a building inspector under Part XII of Chapter 468, Florida Statutes. Nothing aforesaid shall preclude plan review or inspections by the Building Official (See also Section 105.14). On applications in which private provider services are utilized, all time frames shall adhere to time frames as indicated in Florida Statutes 553.791 (7). 107.6.1 Building permits issued in special flood hazard areas on the basis of an affidavit. Pursuant to the requirements of federal regulation for participation in the National Flood Insurance Program (44 C.F.R. Parts 59 and 60), the authority granted to the Building Official to issue permits, to rely on inspections, and to accept plans and construction documents on the basis of affidavits and plans submitted pursuant to Sections 105.14 and 107.6, shall not extend to the flood load and flood resistance construction requirements of the Florida Building Code. 107.6.2 Affidavits Provided Pursuant to Section 553.791, Florida Statutes. For a building or structure in a flood hazard area, the Building Official shall review any affidavit 40 certifying compliance with the flood load and flood-resistant construction requirements of the Florida Building Code. SECTION 108 TEMPORARY STRUCTURES AND USES 108.1 General. The Building Official is authorized to issue a permit for temporary structures and temporary uses. Such permits shall be limited as to time of service, but shall not be permitted for more than 180 days. The Building Official is authorized to grant extensions for demonstrated cause. 108.2 Conformance. Temporary structures and uses shall comply with the requirements in Section 3103 of the Florida Building Code. 108.3 Temporary power. The Building Official is authorized to give permission to temporarily supply and use power in part of an electric installation before such installation has been fully completed and the final certificate of completion has been issued. The part covered by the temporary certificate shall comply with the requirements specified for temporary lighting, heat or power in NFPA 70. 108.4 Termination of approval. The Building Official is authorized to terminate such permit for a temporary structure or use and to order the temporary structure to be removed or use to be discontinued. SECTION 109 FEES 109.1 Payment of fees. A permit shall not be valid until the fees prescribed by law have been paid, nor shall an amendment to a permit be released until the additional fee, if any, has been paid. 109.2 Schedule of permit fees. On buildings, structures, electrical, gas, mechanical, and plumbing systems or alterations requiring a permit, a fee for each permit shall be paid as required, in accordance with the schedule as established by the Village of Tequesta Village Council. 109.2.1 Types of Fees Enumerated. Fees may be charged for but not limited to the following: • Permits; • Plans examination' • Certificates of competency (including fees for applications, examinations, renewal, late renewal, and reciprocity); • Re-inspections; • Administrative fees (including fees for investigative and legal costs incurred in the context of certain disciplinary cases heard by the board); 41 • Variance requests; • Administrative appeals; • Violations; and • Other fees as established by local resolution or ordinance 109.3 Building permit valuations. The applicant for a permit shall provide an estimated permit value at time of application. Permit valuations shall include total value of work, including materials and labor, for which the permit is being issued, such as electrical, gas, mechanical, plumbing equipment and permanent systems. If, in the opinion of the Building Official, the valuation is underestimated on the application, the permit shall be denied, unless the applicant can show detailed estimates to meet the approval of the Building Official. Final building permit valuation shall be set by the Building Official. 109.4 Work commencing before permit issuance. Any person who commences any work on a building, structure, electrical, gas, mechanical or plumbing system before obtaining the necessary permits or without prior approval from the Building Official as permitted in Section 105.2.2 or 105.12 shall be subject to a fee established by the Building Official that shall be in addition to the required permit fees established and adopted by the Village of Tequesta Village Council. This provision shall not apply to emergency work when delay would clearly have placed life or property in imminent danger. But in all such cases the required permit(s) must be applied for within three (3) business days and any unreasonable delay in obtaining those permit(s) shall result in the charge of a triple fee. The payment of a triple fee shall not preclude or be deemed a substitute for prosecution for commencing work without first obtaining a permit. The Building Official may grant extensions of time or waive fees when justifiable cause has been demonstrated in writing. 109.5 Related fees. The payment of the fee for the construction, alteration, removal or demolition for work done in connection to or concurrently with the work authorized by a building permit shall not relieve the applicant or holder of the permit from the payment of other fees that are prescribed by law. 109.6 Refunds. The Building Official is authorized to establish and publish a refund policy through local ordinance or resolution. SECTION 110 INSPECTIONS 110.1 General. Construction or work for which a permit is required shall be subject to inspection by the Building Official and such construction or work shall remain exposed and provided with access for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of this code or of other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of this code or of other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain exposed and provided with access 42 for inspection purposes. The Building Official shall be permitted to require a boundary line survey prepared by a qualified surveyor whenever the boundary lines cannot be readily determined in the field. Neither the Building Official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. 110.1.1 Manufacturers and fabricators. When deemed necessary by the Building Official, he/she shall make, or cause to be made, an inspection of materials or assemblies at the point of manufacture or fabrication. A record shall be made of every such examination and inspection and of all violations of the technical codes. 110.1.2 Inspection service. The Building Official may make, or cause to be made, the inspections required by Section 110. He or she may accept reports of department inspectors, independent inspectors or of recognized inspection services, provided that after investigation he/she is satisfied as to their licensure, qualifications and reliability. A certificate required by any provision of this code shall not be based on such reports unless the same are recorded by the building code inspector or the architect or engineer performing building code inspections in a manner specified by the Building Official. The Building Official shall ensure that all persons making such inspections shall be certified in accordance to Chapter 468 Florida Statues; or licensed under Chapter 471 or 481 Florida Statutes. The Building Official may require the owner to employ an inspection service in the following instances: 1. For buildings or additions of Type I construction; 2. For all major structural alterations; 3. Where the concrete design is based on compressive strength in excess of 3000 pounds per square inch; 4. For pile driving; 5. For buildings with an area greater than 20,000 square feet; 6. For buildings more than two stories in height; or 7. For buildings and structures of unusual design or methods of construction. Such inspectors shall be present when work is underway on the structural elements of the building to adequately attest to its compliance. Such inspectors shall be registered architect, or engineer.An employee of the architect or engineer licensed under Chapter 468, Part XII, Florida Statutes may perform the inspections, under the direction of and with final certification from the architect or engineer. Such inspectors shall submit weekly progress reports including the daily inspections to the building official, and including a code compliance opinion of the resident inspector. At the completion of the construction work or project, the architect or engineer shall submit a certificate of compliance to the Building Official, stating that the work was done in compliance with this code and in accordance with the permitted drawing. Final inspection shall be made by the Building Official before a Certificate of Occupancy or Certificate of Completion is issued; and confirmation inspections may be made at any time to monitor activities and resident inspectors. 43 110.1.3 Affidavit for inspection. With specific prior approval of, and in a format acceptable to the Building Official, an affidavit for certification of inspection may be accepted from the permit qualifier; when accompanied by extensive photographic evidence of sufficient detail to demonstrate code compliance. The photographic evidence shall be comprehensive in the display of the installation and/or construction and job location identifiers. The affidavit and accompanying photographs shall be provided to the inspector onsite, at the next scheduled inspection. If the photographs are found to be insufficient by the Building Official to demonstrate compliance with this code and/or the permitted document, or clearly display location identifiers, or are missing, the inspector shall require the contractor to obtain the services of a registered Florida professional engineer to inspect and certify the installation and/or construction. 110.1.3.1 Exception: Affidavits may not be accepted for inspection of elements of construction which require inspection by the Village of Tequesta under the requirements of Title 44, Code of Federal Regulations, Parts 59 and 60, and the local flood damage prevention ordinance. 110.2 Preliminary inspection. Before issuing a permit, the Building Official is authorized to examine or cause to be examined buildings, structures and sites for which an application has been filed. 110.3 Required inspections. The Building Official upon notification from the permit holder or his or her agent shall make the following inspections, or any other such inspection as deemed necessary and shall either release that portion of the construction or shall notify the permit holder or his or her agent of any violations which must be corrected in order to comply with the technical codes. The Building Official shall determine the timing and sequencing of when inspections occur and what elements are inspected at each inspection. Building 1. Foundation inspection. To be made after trenches are excavated, any required reinforcing steel is in place, forms erected and shall at a minimum include the following building components: Stem-wall Monolithic slab-on-grade Piling/pile caps Footers/grade beams 1.1. Slab Inspection: Concrete slab and under-floor inspections shall be made after in-slab or under-floor reinforcing steel and building service equipment, 44 conduit, piping accessories and other ancillary equipment items are in place, but before any concrete is placed or floor sheathing installed, including the subfloor. 1.2A foundation/Form board survey prepared and certified by a registered surveyor may be required, prior to approval of the slab inspection. The survey shall certify placement of the building on the site, illustrate all surrounding setback dimensions and shall be available at the job site for review by the building inspector. In lieu of providing a survey, the contractor may elect to uncover all property line markers and string-up all property lines in preparation for inspection. 1.3. In flood hazard areas, upon placement of the lowest floor, including basement, and prior to further vertical construction, the elevation certification shall be submitted to the Authority having Jurisdiction. 2. Framing inspection. To be made after the roof, all framing, fire blocking and bracing is in place, all concealing wiring, all pipes, chimneys, ducts and vents are complete and the rough electrical, plumbing, heating wires, pipes and ducts are approved and shall at a minimum include the following building components- Window/door framing -Window U-factor/SHGC as indicated on approved energy calculations Vertical cells/columns Lintel/tie beams Framing/trusses/bracing/connectors (including truss layout and engineered drawings) Draft stopping/fire blocking Curtain wall framing Energy insulation (Insulation R-factor as indicated on approved energy calculations) Accessibility. Verify rough opening dimensions are within tolerances. -Window/door buck attachment 2.1. Insulation Inspection: To be made after the framing inspection is approved and the insulation is in place, according to approved energy calculation submittal Includes wall and ceiling insulation. 45 2.2. Lath and gypsum board inspection for fire-resistance-rated or shear assemblies. Lath and gypsum board inspections shall be made after lathing and gypsum board, interior and exterior, is in place, but before any plastering is applied or gypsum board joints and fasteners are taped and finished. 3. Sheathing inspection. To be made either as part of a dry-in inspection or done separately at the request of the contractor after all roof and wall sheathing and fasteners are complete and shall at a minimum include the following building components: Roof sheathing Wall sheathing -Continuous air barrier -Exterior Siding/Cladding Sheathing fasteners Roof/wall dry-in. NOTE: Sheathing fasteners installed and found to be missing the structural member (shiners) shall be removed and properly reinstalled prior to installation of the dry-in material. Exception: ring shank nails shall be bent over and a new fastener installed. 4. Exterior wall coverings. Shall at a minimum include the following building components in progress inspections: • Exterior wall coverings and veneers • Soffit coverings 5. Roofing inspection. Shall at a minimum be made in at least two inspections and include the following building components: Dry-in Insulation Roof coverings (including In Progress as necessary) -Insulation on roof deck (according to submitted energy calculation) Flashing - Sheathing 46 5.1. Re-Roof sheathing inspection. An affidavit with a notarized signature of a state or locally licensed roofing contractor for the installation of additional sheathing fasteners as required by the Existing Building Code may be accepted at the discretion of the Building Official. 6. Final inspection. To be made after the building, including all sub-trade inspections, is completed and ready for occupancy. 6.1. In flood hazard areas, as part of the final inspection, a final certification of the lowest floor elevation or the elevation to which a building is dry floodproofed, as applicable, shall be submitted to the authority having jurisdiction. 7. Swimming pool inspection. First inspection to be made after excavation and installation of reinforcing steel, bonding and main drain and prior to placing of concrete shell. 1. Steel reinforcement inspection 2. Underground electric inspection. 3. Underground piping inspection including a pressure test. 4. Underground electric inspection under deck area (including the equipotential bonding) 5. Underground piping inspection under deck area.. 6. Deck inspection: to be made prior to installation of the deck material (with forms, deck drains, and any reinforcement in place 7. Safety Inspection; Made prior to filling the pool with the bonding connections made, the proper drain covers installed and the final barriers installed. 8. Final pool piping. 9. Final Electrical inspection. 10. Final inspection to be made when the swimming pool is complete and all required enclosure requirements are in place. In order to pass final inspection and receive a certificate of completion, a residential swimming pool must meet the requirements relating to pool safety features as described in Section 454.2.17and R4501 .17 of this code. 8. Demolition inspections. First inspection to be made after all utility connections have been disconnected and secured in such manner that no unsafe or unsanitary conditions shall exist during or after demolition operations. Final inspection to be made after all demolition work is completed. 9. Manufactured building inspections. The Department of Building Safety shall inspect construction of foundations; connecting buildings to foundations; installation of parts identified on plans as site installed items, joining the modules, including utility crossovers; utility connections from the building to utility lines on 47 site; and any other work done on site which requires compliance with the Florida Building Code. Additional inspections may be required for public educational facilities (see Section 453.27.20 of this code). 10. Where impact resistant coverings or impact resistant systems are installed, the Building Official shall schedule adequate inspections of impact resistant coverings or impact resistant systems to determine the following: The system indicated on the plans was installed. The system is installed in accordance with the manufacturer's installation instructions and the product approval. Electrical 1. Underground inspection. To be made after trenches or ditches are excavated, conduit or cable installed, and before any backfill is put in place. 2. Rough-in inspection. To be made after the roof, framing, fireblocking and bracing is in place and prior to the installation of wall or ceiling membranes. 3. Final inspection. To be made after the building electrical system is complete, all required electrical fixtures are in place and properly connected or protected, and the structure is ready for occupancy. 4. Existing Swimming Pools. To be made after all repairs or alterations are complete, all required electrical equipment, GFCI protection, and equipotential bonding are in place on said alterations or repairs. Plumbing 1 . Underground inspection. To be made after trenches or ditches are excavated, piping installed, and before any backfill is put in place. 2. Rough-in inspection. To be made after the roof, framing, fireblocking and bracing is in place and all soil, waste and vent piping is complete, and prior to this installation of wall or ceiling membranes. -includes plumbing provisions of the energy code and approved energy calculations provisions. 3. Final inspection. To be made after the building plumbing system is complete, all plumbing fixtures are in place and properly connected, and the structure is ready for occupancy. Note: See Section 312 of the Florida Building Code, Plumbing for required tests. 48 Mechanical 1. Underground inspection. To be made after trenches or ditches are excavated, underground duct and fuel piping installed, and before any backfill is put in place. 2. Rough-in inspection. To be made after the roof, framing, fire blocking and bracing are in place and all ducting, and other concealed components are complete, and prior to the installation of wall or ceiling membranes. -includes mechanical provisions of the energy code and approved energy calculations provisions. 3. Final inspection. To be made after the building mechanical system is complete, the mechanical system is in place and properly connected, and the structure is ready for occupancy. Gas 1 . Rough piping inspection. To be made after all new piping authorized by the permit has been installed, and before any such piping has been covered or concealed or any fixtures or gas appliances have been connected. -includes gas provisions of the energy code and approved energy calculations provisions. 2. Final piping inspection. To be made after all piping authorized by the permit has been installed and after all portions which are to be concealed by plastering or otherwise have been so concealed, and before any fixtures or gas appliances have been connected. This inspection shall include a pressure test. 3. Final inspection. To be made on all new gas work authorized by the permit and such portions of existing systems as may be affected by new work or any changes, to ensure compliance with all the requirements of this code and to assure that the installation and construction of the gas system is in accordance with reviewed plans. Site Debris 1.The contractor and/or owner of any active or inactive construction project shall be responsible for the clean-up and removal of all construction debris or any other miscellaneous discarded articles during the course of the construction project and prior to receiving final inspection approval. Construction job sites must be kept clean and in a safe condition at all times. 2.All debris shall be kept in such a manner as to prevent it from being spread by any means. 49 110.3.1 Footing and foundation inspection. Footing and foundation inspections shall be made after excavations for footings are complete and any required reinforcing steel is in place. For concrete foundations, any required forms shall be in place prior to inspection. Materials for the foundation shall be on the job, except where concrete is ready mixed in accordance with ASTM C 94, the concrete need not be on the job. 110.3.2 Concrete slab and under-floor inspection. Concrete slab and under-floor inspections shall be made after in-slab or under-floor reinforcing steel and building service equipment, conduit, piping accessories and other ancillary equipment items are in place, but before any concrete is placed or floor sheathing installed, including the subfloor. 110.3.3 Lowest floor elevation. In flood hazard areas, upon placement of the lowest floor, including the basement, and prior to further vertical construction, the elevation certification required in Section 1612.4 of the Florida Building Code, Building and Section R322 of the Florida Building Code, Residential, shall be submitted to the Building Official. 110.3.4 Frame inspection. Framing inspections shall be made after the roof deck or sheathing, all framing, fire blocking and bracing are in place and pipes, chimneys and vents to be concealed are complete and the rough electrical, plumbing, heating wires, pipes and ducts are approved. 110.3.5 Lath, gypsum board and gypsum panel product inspection. Lath, gypsum board and gypsum panel product inspections shall be made after lathing, gypsum board and gypsum panel products, interior and exterior, are in place, but before any plastering is applied or gypsum board and gypsum panel product joints and fasteners are taped and finished. Exception: Gypsum board and gypsum panel products that are not part of a fire- resistance-rated assembly or a shear assembly. 110.3.6 Weather-exposed balcony and walking surface waterproofing. Where balcony or other elevated walking surfaces are exposed to water from direct or blowing rain, snow or irrigation, and the structural framing is protected by an impervious moisture barrier, all elements of the impervious-moisture-barrier system shall not be concealed until inspected and approved. 110.3.7 Fire- and smoke-resistant penetrations. Protection of joints and penetrations in fire-resistance rated assemblies, smoke barriers and smoke partition shall not be concealed from view until inspected and approved. 110.3.8 Energy efficiency inspections. Inspections shall be made to determine compliance with FBC, Energy Conservation and-confirm with the approved energy code submittal (by appropriate trade) and corresponding mandatory requirements and shall include, but not be limited to, inspections for: corresponding envelope insulation 50 R- and U-values, fenestration U-value and Solar Heat Gain Coefficient, duct system R-value, and HVAC, lighting, electrical and water-heating equipment efficiency. 110.3.9 Other inspections. In addition to the inspections specified in Sections 110.3 through 110.3.7, the Building Official is authorized to make or require other inspections of any construction work to ascertain compliance with the provisions of this code and other laws that are enforced by the department of building safety. 110.3.10 Special inspections. Reserved. 110.3.11 Final inspection. The final inspection shall be made after all work required by the building permit is completed. 110.3.11.1 Flood hazard documentation. If located in a flood hazard area, coastal high hazard areas or coastal A zones, documentation as required in Section 1612.5 of the Florida Building Code, Building; or Section R322 of the Florida Building Code, Residential, shall be submitted to the Building Official prior to the final inspection. 110.3.11.2 Commercial Energy Code documentation. If required by energy code path submittal, confirmation that commissioning result requirements have been received by building owner. 110.3.11.3 Residential Energy Code documentation. If required by energy code path submittal (Section R405), confirmation that the envelope and duct test requirements shall be received by Building Official. 110.3.12 Termites. Building components and building surroundings required to be protected from termite damage in accordance with Section 1503.7, Section 2304.13 or Section 2304.11.6, specifically required to be inspected for termites in accordance with Section 2114, or required to have chemical soil treatment in accordance with Section 1816 shall not be covered or concealed until the release from the Building Official has been received. 110.3.13 Impact resistant coverings or systems. Where impact resistant coverings or systems are installed to meet requirements of this code, the Building Official shall schedule adequate inspections of impact resistant coverings or systems to determine the following: 1 . The system indicated on the plans was installed. 2. The system is installed in accordance with the manufacturer's installation instructions and the product approval. 110.4 Inspection agencies. The Building Official is authorized to accept reports of approved inspection agencies, provided such agencies satisfy the requirements as to qualifications and reliability. 51 110.5 Inspection requests. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the Building Official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. 110.6 Approval required. Work shall not be done beyond the point indicated in each successive inspection without first obtaining the approval of the Building Official. The Building Official, upon notification, shall make the requested inspections and shall either indicate the portion of the construction that is satisfactory as completed, or notify the permit holder or his or her agent wherein the same fails to comply with this code. Any portions that do not comply shall be corrected and such portion shall not be covered or concealed until authorized by the Building Official. 110.7 Shoring. For threshold buildings, shoring and associated formwork or falsework shall be designed and inspected by a Florida licensed professional engineer, prior to any required mandatory inspections by the threshold building inspector. 110.8 Threshold building. 110.8.1 During new construction or during repair or restoration projects in which the structural system or structural loading of a building is being modified, the enforcing agency shall require a special inspector to perform structural inspections on a threshold building pursuant to a structural inspection plan prepared by the engineer or architect of record. The structural inspection plan must be submitted to the enforcing agency prior to the issuance of a building permit for the construction of a threshold building. The purpose of the structural inspection plans is to provide specific inspection procedures and schedules so that the building can be adequately inspected for compliance with the permitted documents. The special inspector may not serve as a surrogate in carrying out the responsibilities of the Building Official, the architect, or the engineer of record. The contractor's contractual or statutory obligations are not relieved by any action of the special inspector. 110.8.2 The special inspector shall determine that a professional engineer who specializes in shoring design has inspected the shoring and reshoring for conformance with the shoring and reshoring plans submitted to the enforcing agency. A fee simple title owner of a building, which does not meet the minimum size, height, occupancy, occupancy classification, or number-of-stories criteria which would result in classification as a threshold building under Section 553.71(7), Florida Statutes, may designate such building as a threshold building, subject to more than the minimum number of inspections required by the Florida Building Code. 110.8.3 The fee owner of a threshold building shall select and pay all costs of employing a special inspector, but the special inspector shall be responsible to the enforcement agency. The inspector shall be a person certified, licensed or registered under Chapter 471, Florida Statutes, as an engineer or under Chapter 481, Florida Statutes, as an architect. 52 110.8.4 The Village of Tequesta shall require that, on every threshold building: 110.8.4.1 The special inspector, upon completion of the building and prior to the issuance of a certificate of occupancy, file a signed and sealed statement with the enforcement agency in substantially the following form: "To the best of my knowledge and belief, the above described construction of all structural load-bearing components complies with the permitted documents, and the shoring and reshoring conforms to the shoring and reshoring plans submitted to the enforcement agency." 110.8.4.2 Any proposal to install an alternate structural product or system to which building codes apply be submitted to the enforcement agency for review for compliance with the codes and made part of the enforcement agency's recorded set of permit documents. 110.8.4.3 All shoring and reshoring procedures, plans and details be submitted to the enforcement agency for recordkeeping. Each shoring and reshoring installation shall be supervised, inspected and certified to be in compliance with the shoring documents by the contractor. 110.8.4.4 All plans for the building which are required to be signed and sealed by the architect or engineer of record contain a statement that, to the best of the architect's or engineer's knowledge, the plans and specifications comply with the applicable minimum building codes and the applicable fire-safety standards as determined by the local authority in accordance with this Section and Chapter 633, Florida Statutes. 110.8.5 The Village of Tequesta shall not issue a building permit for construction of any threshold building except to a licensed general contractor, as defined in Section 489.105(3)(a), Florida Statutes, or to a licensed building contractor, as defined in Section 489.105(3)(b), Florida Statutes, within the scope of her or his license. The named contractor to whom the building permit is issued shall have the responsibility for supervision, direction, management and control of the construction activities on the project for which the building permit was issued. 110.8.6 The Department of Building Safety may allow a special inspector to conduct the minimum structural inspection of threshold buildings required by this code, Section 553.73, Florida Statutes, without duplicative inspection by the Department of Building Safety. The Building Official is responsible for ensuring that any person conducting inspections is qualified as a building inspector under Part XII of Chapter 468, Florida Statutes, or certified as a special inspector under Chapter 471 or 481, Florida Statutes. Inspections of threshold buildings required by Section 553.79(5), Florida Statutes, are in addition to the minimum inspections required by this code. 110.9 Impact of construction. All construction activity regulated by this code shall be performed in a manner so as not to adversely impact the condition of adjacent property, unless such activity is permitted to affect said property pursuant to a consent granted by 53 the applicable property owner, under terms or conditions agreeable to the applicable property owner. This includes, but is not limited to, the control of dust, noise, water or drainage runoffs, debris, and the storage of construction materials. New construction activity shall not adversely impact legal historic surface water drainage flows serving adjacent properties, and may require special drainage design complying with engineering standards to preserve the positive drainage patterns of the affected sites. Accordingly, developers, contractors and owners of all new residential development, including additions, pools, patios, driveways, decks or similar items, on existing properties resulting in a significant decrease of permeable land area on any parcel or has altered the drainage flow on the developed property shall, as a permit condition, provide a professionally prepared drainage plan clearly indicating compliance with this paragraph. Upon completion of the improvement, a certification from a licensed professional, as appropriate under Florida law, shall be submitted to the inspector in order to receive approval of the final inspection. SECTION 111 CERTIFICATE OF OCCUPANCY 111.1 Use and occupancy. A building or structure shall not be used or occupied, and a change in the existing use or occupancy classification of a building or structure or portion thereof shall not be made, until the Building Official has issued a certificate of occupancy therefore as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of this code or of other ordinances of the jurisdiction. Exception: Certificates of occupancy are not required for work exempt from permits under Section 105.2. 111.2 Certificate issued. After the Building Official inspects the building or structure and finds no violations of the provisions of this code or other laws that are enforced by the department of building safety, the Building Official shall issue a certificate of occupancy that contains the following: 1 . The building permit number. 2. The address of the structure. 3. The name and address of the owner or the owner's authorized agent. 4. A description of that portion of the structure for which the certificate is issued. 5. A statement that the described portion of the structure has been inspected for compliance with the requirements of this code for the occupancy and division of occupancy and the use for which the proposed occupancy is classified. 54 6. For buildings and structures in flood hazard areas, a statement that documentation of the as-built lowest floor elevation has been provided and is retained in the records of the authority having jurisdiction. 7. The name of the Building Official. 8. The edition of the code under which the permit was issued. 9. The use and occupancy, in accordance with the provisions of Chapter 3. 10. The type of construction as defined in Chapter 6. 11. The design occupant load. 12. If an automatic sprinkler system is provided, whether the sprinkler system is required. 13. Any special stipulations and conditions of the building permit. 111.3 Temporary occupancy. The Building Official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The Building Official shall set a time period during which the temporary certificate of occupancy is valid. 111.4 Revocation. The Building Official is authorized to, in writing, suspend or revoke a certificate of occupancy or completion issued under the provisions of this code wherever the certificate is issued in error, or on the basis of incorrect information supplied, or where it is determined that the building or structure or portion thereof is in violation of any ordinance or regulation or any of the provisions of this code. 111.5 Certificate of Completion. A Certificate of Completion is proof that a structure or system is complete and for certain types of permits is released for use and may be connected to a utility system. This certificate does not grant authority to occupy a building, such as shell building, prior to the issuance of a Certificate of Occupancy. SECTION 112 SERVICE UTILITIES 112.1 Connection of service utilities. No person shall make connections from a utility, source of energy, fuel or power to any building or system that is regulated by this code for which a permit is required, until released by the Building Official. 112.2 Temporary connection. The Building Official shall have the authority to authorize the temporary connection of the building or system to the utility source of energy, fuel or power. 55 112.3 Authority to disconnect service utilities. The Building Official shall have the authority to authorize disconnection of utility service to the building, structure or system regulated by this code and the referenced codes and standards set forth in Section 101.4 in case of emergency where necessary to eliminate an immediate hazard to life or property or when such utility connection has been made without the approval required by Section 112.1 or 112.2. The Building Official shall notify the serving utility, and wherever possible the owner and occupant of the building, structure or service system of the decision to disconnect prior to taking such action. If not notified prior to disconnecting, the owner or occupant of the building, structure or service system shall be notified in writing, as soon as practical thereafter. SECTION 113 BOARD OF APPEALS RESERVED SECTION 114 VIOLATIONS 114.1 Unlawful acts. It shall be unlawful for any person, firm or corporation to erect, construct, alter, extend, repair, move, remove, demolish or occupy any building, structure or equipment regulated by this code, or cause same to be done, in conflict with or in violation of any of the provisions of this code. 114.2 Notice of violation. The Building Official is authorized to serve a notice of violation or order on the person responsible for the erection, construction, alteration, extension, repair, moving, removal, demolition or occupancy of a building or structure in violation of the provisions of this code, or in violation of a permit or certificate issued under the provisions of this code. Such order shall direct the discontinuance of the illegal action or condition and the abatement of the violation. 114.3 Prosecution of violation. If the notice of violation is not complied with promptly, the Building Official is authorized to request the legal counsel of the jurisdiction to institute the appropriate proceeding at law or in equity to restrain, correct or abate such violation, or to require the removal or termination of the unlawful occupancy of the building or structure in violation of the provisions of this code or of the order or direction made pursuant thereto. 114.4 Violation penalties. Any person who violates a provision of this code or fails to comply with any of the requirements thereof or who erects, constructs, alters or repairs a building or structure in violation of the approved construction documents or directive of the Building Official, or of a permit or certificate issued under the provisions of this code, shall be subject to penalties as prescribed by law. 56 SECTION 115 STOP WORK ORDER 115.1 Authority. Whenever the Building Official finds any work regulated by this code being performed in a manner either contrary to the provisions of this code or dangerous or unsafe, the Building Official is authorized to issue a stop work order. 115.2 Issuance. The stop work order shall be in writing and shall be given to the owner of the property involved, the owner's authorized agent or the person performing the work. Upon issuance of a stop work order, the cited work shall immediately cease. The stop work order shall state the reason for the order and the conditions under which the cited work will be permitted to resume. 115.3 Unlawful continuance. Any person who shall continue any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be subject to penalties as prescribed by law. SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT 116.1 Unsafe buildings or systems. All buildings, structures, electrical, gas, mechanical or plumbing systems which are unsafe, unsanitary, or do not provide adequate egress, or which constitute a fire hazard, or are otherwise dangerous to human life, or which in relation to existing use, constitute a hazard to safety or health, are considered unsafe buildings or service systems. All such unsafe buildings, structures or service systems are hereby declared illegal and shall be ordered by the Building Official to be abated by the owner, through repair and rehabilitation or by demolition in accordance with this Code. The extent or repairs shall be determined by the Building Official. 116.1.1 When the Building Official determines a building, structure, electrical, gas, mechanical or plumbing system or portion thereof is unsafe, as set forth in this Code he/she shall provide the owner, agent or person in control of such building, structure, electrical, gas, mechanical or plumbing system a written notice of violation stating the defects thereof. This notice shall require the owner within a stated time either to complete specified repairs or improvements, or to demolish and remove the building, structure, electrical, gas, mechanical or plumbing system or portion thereof. At the option of the Village of Tequesta, the processes and procedures for code enforcement under Chapter 162, Florida Statutes, or Article V, Sec. 14-121 , and Appendix B of the Village of Tequesta Code of Ordinances may be utilized to abate a violation under this section. If the statutory method of enforcement is invoked, the Building Official shall act in the role of code inspector as authored in Section 114 of this code to initiate enforcement proceedings, and notice shall be in accordance with the provisions of the Statute. 116.1.2 If necessary, the notice shall also require the building, structure, electrical, gas, mechanical, plumbing systems or portion thereof to be vacated and/or 57 disconnected, and not reoccupied and/or reconnected until the specified repairs and improvements are completed, inspected and approved by the Building Official. The Building Official shall post at each entrance to the building a placard stating: THIS BUILDING IS UNSAFE AND ITS USE OR OCCUPANCY HAS BEEN PROHIBITED BY THE BUILDING OFFICIAL. This placard shall remain posted until the required repairs are made or demolition is completed. It shall be unlawful for any person, firm or corporation or its officers, agents, or other servants, to remove the posting without written permission of the Building Official, or for any person to enter the building, or use the building or system(s) except for the purpose of making the required repairs or of demolishing same. 116.1.3 In case the owner, agent, or person in control cannot be found within the stated time limit, or, if such owner, agent, or person in control shall fail, neglect, or refuse to comply with notice to repair, rehabilitation or to demolish, and remove said building, structure, electrical, gas, mechanical or plumbing system or portion thereof, the Building Official, acting as a code inspector, shall notify an enforcement board and request a hearing. In the case of the violation posing a serious threat, and after having ascertained the cost, the Building Official may take action to cause such building, structure, electrical, gas, mechanical or plumbing system or portion thereof, to be demolished, secured, repaired, or required to remain vacant or unused. Taking such action does not create a continuing obligation on the part of the Building Official to continue with maintaining such building, structure or system, or create liability for any damage to the property. 116.1.4 The decision of the Building Official shall be final in cases of emergency, which, in the opinion of the Building Official, involve imminent danger to human life or health, or the property of others. He/she shall promptly cause such building, structure, electrical, gas, mechanical or plumbing system or portion thereof to be made safe or cause its removal. For this purpose, he/she may at once enter such structure or land on which it stands, or abutting land or structures, which such assistance and at such cost as he may deem necessary. He/she may order the vacating of adjacent structures and may require the protection of the public by appropriate fence or such other means as may be necessary, and for this purpose may close a public or private way. 116.2 Conditions. Structures or existing equipment that are or hereafter become unsafe, insanitary or deficient because of inadequate means of egress facilities, inadequate light and ventilation, or which constitute a fire hazard, or are otherwise dangerous to human life or the public welfare, or that involve illegal or improper occupancy or inadequate maintenance, shall be deemed an unsafe condition. Unsafe structures shall be taken down and removed or made safe, as the Building Official deems necessary and as provided for in this section. A vacant structure that is not secured against entry shall be deemed unsafe. 58 116.3 Record. The Building Official shall cause a report to be filed on an unsafe condition. The report shall state the occupancy of the structure and the nature of the unsafe condition. 116.4 Notice. If an unsafe condition is found, the Building Official shall serve on the owner, agent or person in control of the structure, a written notice that describes the condition deemed unsafe and specifies the required repairs or improvements to be made to abate the unsafe condition, or that requires the unsafe structure to be demolished within a stipulated time. Such notice shall require the person thus notified to declare immediately to the Building Official acceptance or rejection of the terms of the order. 116.5 Method of service. Such notice shall be deemed properly served if a copy thereof is (a) delivered to the owner personally; (b) sent by certified or registered mail addressed to the owner at the last known address with the return receipt requested; or (c) delivered in any other manner as prescribed by local law. If the certified or registered letter is returned showing that the letter was not delivered, a copy thereof shall be posted in a conspicuous place in or about the structure affected by such notice. Service of such notice in the foregoing manner upon the owner's agent or upon the person responsible for the structure shall constitute service of notice upon the owner. 116.6 Restoration. Where the structure or equipment determined to be unsafe by the Building Official is restored to a safe condition, to the extent that repairs, alterations or additions are made or a change of occupancy occurs during the restoration of the structure, such repairs, alterations, additions and change of occupancy shall comply with the requirements of Section 105.2.2 and the Florida Building Code, Existing Building. 116.7 Enforcement proceedings; hearing. Violation proceedings and hearings for unsafe structures and equipment will be conducted before the Village of Tequesta special magistrate in accordance with the provisions set forth in Chapter 162, Florida Statutes. The owner of property that is subject to an enforcement proceeding before the special magistrate or court is required to make disclosures as outlined in Chapter 162, Florida Statutes, before a transfer of property, and failure to make the required disclosures creates a presumption of fraud. 116.8 Administrative fines; costs to repair; liens. All costs associated with taking a case before the special magistrate shall be recovered where the jurisdiction prevails. Whenever one of the orders of the special magistrate has not been complied with by the time set for compliance, for each day thereafter during which said violation continues past the date set for compliance, the special magistrate may impose a fine. All costs incurred as a result of actions taken pursuant to Section 114 are charged to the violator. 116.9 Appeal. An aggrieved party, including the Village of Tequesta, may appeal a final administrative order of an enforcement board or special magistrate to the circuit court. Such an appeal shall not be a hearing de novo but shall be limited to appellate review of the record created before the enforcement board. An appeal shall be filed within 30 days of the execution of the order to be appealed. 59 SECTION 117 VARIANCES IN FLOOD HAZARD AREAS 117.1 Flood hazard areas. Pursuant to Section 553.73(5), Florida Statutes, the variance procedures adopted in the local floodplain management ordinance shall apply to requests submitted to the Building Official for variances to the provisions of Section 1612.4 of the Florida Building Code, Building or, as applicable, the provisions of R322 of the Florida Building Code, Residential. This section shall not apply to Section 3109 of the Florida Building Code, Building. Section 2: Each and every other Section and Subsection of Chapter 14. Buildings and building regulations. shall remain in full force and effect as previously adopted. Section 3: All ordinances or parts of ordinances in conflict be and the same are hereby repealed. Section 4: Should any section or provision of this Ordinance or any portion thereof, any paragraph, sentence or word be declared by a court of competent jurisdiction to be invalid, such decision shall not affect the validity of the remainder of this Ordinance. Section 5: Specific authority is hereby granted to codify this Ordinance. Section 6: The Village Manager is directed to transmit a copy of this ordinance to the Florida Building Commission no later than 30 days following its final adoption. Section 7: The Village Manager is further directed to assure that this ordinance is made available immediately to the general public in a usable format; Section 8: This Ordinance shall take effect immediately upon adoption. 60 ORDINANCE Date 19-23 02-08-2024 Upon Second Reading Motion Council Member Patrick Painter Second Council Member Rick Sartory FOR AGAINST ABSENT CONFLICT Mayor Molly Young ®x Vice-Mayor Laurie Brandon Council ®x 1:1 El Member Patrick Painter Council M ® E Member Rick Sartory Council Mx ri Member Thomas G. Bradford ®x F7 El The Mayor thereupon declared the Ordinance duly passed and adopted. MAYOR OF TEQUESTA: Molly Young ` PC,ORPO'9gpG 1,�• SEA �•.•.�_ ATTEST: _ /NconpoR ED: F4 19 • '' ' Lori McWilliams, MMC Village Clerk Fiscal Impact Statement An Ordinance of the Village Council of the Village of Tequesta, Florida, Amending the Village Code of Ordinances at Chapter 14. Buildings and Building Regulations. Article II. Buildings, Section 14-32, to Adopt local amendments to Chapter 1. Administration, of the Florida Building Code 81h Edition, (2023). This Fiscal Impact Statement is provided in accordance with Section 553.73(4)(h), Florida Statutes, and may be revised following its initial posting. Summary of the proposed ordinance (including a statement of public purpose). With the new Florida Building Code being effective on January 1st, 2024, the Village of Tequesta Code of Ordinances, Chapter 14. Buildings and Building Regulations, Article II. Buildings, Sec. 14-32, will align with the administrative chapter of the code for local applicability. The Florida Building Code governs the design and construction of buildings within the Village of Tequesta. Chapter 1 of the Florida Building Code contains the administrative (non-technical) provisions of the Florida Building Code, which may be amended by local governments. The Village's Building Official is proposing amendments to Chapter 1, administrative portions of the Florida Building Code. Recent changes in state law that have been passed are included in these local Chapter 1 amendments. These include the Milestone requirements, certain low voltage permitting requirements, unsafe structures and the timeline of reviewing the application for a building permit. Estimate of direct economic impact of the proposed ordinance on for profit businesses within the Village, including compliance costs, fees, and expenses. There are no direct compliance costs above any that would be realized under the model administrative Chapter 1 of the Florida Building Code. In other words, the Village's local amendments to Chapter 1 will have no direct compliance cost to local businesses. There are also no additional fees that will be imposed as a result of these local Chapter 1 amendments. This ordinance does not increase any fees which are set by separate resolution of the Village Council from time to time and therefore will have no direct compliance cost to local businesses.. Finally, by law, building code related expenses are meant to cover the cost of running the building department and implementing the Florida Building Code within the Village. This ordinance does not change the Village's current regulatory structure or costs in any way and therefore will have no direct compliance cost to local businesses. Good faith estimate of the number of businesses likely to be impacted by the proposed ordinance. Any business in the Village of Tequesta required to apply for a building permit will be impacted by this ordinance. PART 1—SCOPE AND APPLICATION SECTION 101 GENERAL 101.1 Title. These regulations shall be known as the Florida Building Code,hereinafter referred to as"this code." 101.2 Scope.The provisions of this code shall apply to the construction,alteration,relocation,enlargement, replacement,repair,equipment,use and occupancy,location,maintenance,removal and demolition of every building or structure or any appurtenances connected or attached to such buildings or structures. Exception: 1. Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories above grade plane in height with a separate means of egress and their accessory structures not more than three stories above grade plane in height, shall comply with the Florida Building Code,Residential. 2. Code Requirements that address snow loads and earthquake protection are pervasive; they are left in place but shall not be utilized or enforced because Florida has no snow load or earthquake threat. 101.2.1 Appendices.Provisions in the appendices to the Florida Building Code shall not apply unless specifically adopted. 101.2.2 Florida Building Code, Residential Construction standards or practices which are not covered by Florida Building Code, Residential volume shall be in accordance with the provisions of Florida Building Code,Building. 101.3 Intent. The purpose of this code is to establish the minimum requirements to safeguard the public health,safety and general welfare through structural strength,means of egress facilities,stability,sanitation, adequate light and ventilation, energy conservation, and safety to life and property from fire and other hazards attributed to the built environment and to provide safety to fire fighters and emergency responders during emergency operations. 101.3.1 Quality control.Quality control of materials and workmanship is not within the purview of this code except as it relates to the purposes stated herein. 101.3.2 Warranty and Liability. The permitting,plan review or inspection of any building, system or plan by the Village of Tequesta,under the requirements of this code, shall not be construed in any court as a warranty of the physical condition of such building, system or plan or their adequacy.The Village of Tequesta shall not be liable in tort for damages or hazardous or illegal condition or inadequacy in such building,system or plan,nor for any failure of any component of such,which may occur subsequent to such inspection or permitting. Further, no employee shall be liable in tort for damage from such conditions,in accordance with Section 768.28 Florida Statutes,as may be amended or replaced. 101.4 Referenced codes. The other codes listed in Sections 101.4.1 through 101.4.11 and referenced elsewhere in this code shall be considered part of the requirements of this code to the prescribed extent of each such reference. 101.4.1 Gas.The provisions of the Florida Building Code,Fuel Gas shall apply to the installation of gas piping from the point of delivery,gas appliances and related accessories as covered in this code. These requirements apply to gas piping systems extending from the point of delivery to the inlet connections 1 of appliances and the installation and operation of residential and commercial gas appliances and related accessories. 101.4.2 Mechanical. The provisions of the Florida Building Code, Mechanical shall apply to the installation, alterations, repairs and replacement of mechanical systems, including equipment, appliances, fixtures, fittings and/or appurtenances, including ventilating, heating, cooling, air- conditioning and refrigeration systems,incinerators and other energy-related systems. 101.4.3 Plumbing. The provisions of the Florida Building Code, Plumbing shall apply to the installation, alteration, repair and replacement of plumbing systems, including equipment, appliances, fixtures, fittings and appurtenances, and where connected to a water or sewage system and all aspects of a medical gas system. 101.4.4 Property maintenance. The provisions of the Village of Tequesta Code of Ordinances Article V,Sec. 14-121,and Appendix B shall apply to all matters governing property maintenance. 101.4.5 Fire prevention. For provisions related to fire prevention, refer to the Florida Fire Prevention Code. The Florida Fire Prevention Code shall apply to matters affecting or relating to structures, processes and premises from the hazard of fire and explosion arising from the storage,handling or use of structures, materials or devices; from conditions hazardous to life, property or public welfare in the occupancy of structures or premises;and from the construction,extension,repair,alteration or removal of fire suppression,automatic sprinkler systems and alarm systems or fire hazards in the structure or on the premises from occupancy or operation. 101.4.6 Energy.The provisions of the Florida Building Code,Energy Conservation shall apply to all matters governing the design and construction of buildings for energy efficiency. 101.4.7 Existing buildings.The provisions of the Florida Existing Building Code shall apply to matters governing the repair,alteration, change of occupancy,addition to and relocation of existing buildings. 101.4.8 Accessibility. For provisions related to accessibility,refer to the Florida Building Code, Accessibility. 101.4.9 Manufactured buildings.For additional administrative and special code requirements,see Section 458,Florida Building Code. Building, and Rule 61-41 Florida Administrative Code. 101.4.10 Electrical. The provisions of Chapter 27 of the Florida Building Code,Building Volume shall apply to the installation of electrical systems, including alterations, repairs, replacement, equipment, appliances, fixtures,fittings and appurtenances thereto. 101.4.11 Flood Damage Prevention. The provisions of the Village of Tequesta Code of Ordinances Chapter 78.Article XII shall be considered part of this code relative to flood control. 101.5 Building Official. Whenever,the Building Official is mentioned in this code, it is also intended to mean the Building Official's designee,wherever applicable. SECTION 102 APPLICABILITY 102.1 General. Where there is a conflict between a general requirement and a specific requirement, the specific requirement shall be applicable.Where,in any specific case,different sections of this code specify different materials,methods of construction or other requirements,the most restrictive shall govern. 2 102.1.1 The Florida Building Code does not apply to, and no code enforcement action shall be brought with respect to,zoning requirements, land use requirements and owner specifications or programmatic requirements which do not pertain to and govern the design, construction, erection, alteration, modification, repair or demolition of public or private buildings, structures or facilities or to programmatic requirements that do not pertain to enforcement of the Florida Building Code. Additionally,a local code enforcement agency may not administer or enforce the Florida Building Code, Building to prevent the siting of any publicly owned facility, including, but not limited to, correctional facilities, juvenile justice facilities, or state universities, community colleges, or public education facilities,as provided by law. 102.2 Building. The provisions of the Florida Building Code shall apply to the construction, erection, alteration, modification, repair, equipment, use and occupancy, location, maintenance, removal and demolition of every public and private building, structure or facility or floating residential structure, or any appurtenances connected or attached to such buildings, structures or facilities. Additions, alterations, repairs and changes of use or occupancy group in all buildings and structures shall comply with the provisions provided in the Florida Building Code, Existing Building. The following buildings, structures and facilities, except for those located in a Special Flood Hazard Area are exempt from the Florida Building Code as provided by law, and any further exemptions shall be as determined by the legislature and provided by law: (a)Building and structures specifically regulated and preempted by the federal government. (b)Railroads and ancillary facilities associated with the railroad. (c)Nonresidential farm buildings on farms. (d)Temporary buildings or sheds used exclusively for construction purposes. (e)Mobile or modular structures used as temporary offices, except that the provisions of Part II (Section 553.501-553.513,Florida Statutes)relating to accessibility by persons with disabilities shall apply to such mobile or modular structures. Permits shall be required for structural support and tie down, electric supply and all other such utility connections to such mobile or modular structures as required by this jurisdiction. (f)Those structures or facilities of electric utilities, as defined in Section 366.02, Florida Statutes, which are directly involved in the generation,transmission,or distribution of electricity. (g)Temporary sets, assemblies, or structures used in commercial motion picture or television production,or any sound-recording equipment used in such production,on or off the premises. (h) Chickees constructed by the Miccosukee Tribe of Indians of Florida or the Seminole Tribe of Florida. As used in this paragraph,the term "chickee" means an open-sided wooden but that has a thatched roof of palm or palmetto or other traditional materials, and that does not incorporate any electrical,plumbing,or other non-wood features. (i) Family mausoleums not exceeding 250 square feet (23 m2) in area which are prefabricated and assembled on site or preassembled and delivered on site and have walls,roofs,and a floor constructed of granite,marble, or reinforced concrete. 3 0) Temporary housing provided by the Department of Corrections to any prisoner in the state correctional system. (k)A building or structure having less than 1,000 square feet(93 m2)which is constructed and owned by a natural person for hunting and which is repaired or reconstructed to the same dimension and condition as existed on January 1,2011,if the building or structure: 1. Is not rented or leased or used as a principal residence; 2. Is not located within the 100-year floodplain according to the Federal Emergency Management Agency's current Flood Insurance Rate Map;and 3. Is not connected to an off-site electric power or water supply. (1)Service providers of water,sewer,storm,gas,cable,telephone,or other similar utility systems are exempt to the point of service connection for the building or structure. 102.2.1 In addition to the requirements of Section 553.79 and 553.80,Florida Statutes,facilities subject to the provisions of Chapter 395, Florida Statutes, and Part II of Chapter 400, Florida Statutes, shall have facility plans reviewed and construction surveyed by the state agency authorized to do so under the requirements of Chapter 395,Florida Statutes,and Part lI of Chapter 400,Florida Statutes, and the certification requirements of the federal government. 102.2.2 Residential buildings or structures moved into or within the Village of Tequesta shall not be required to be brought into compliance with the state minimum building code in force at the time the building or structure is moved,provided: 1. The building or structure is structurally sound and in occupiable condition for its intended use; 2. The occupancy use classification for the building or structure is not changed as a result of the move; 3. The building is not substantially remodeled; 4. Current fire code requirements for ingress and egress are met; 5. Electrical, gas and plumbing systems meet the codes in force at the time of construction and are operational and safe for reconnection;and 6. Foundation plans are sealed by a professional engineer or architect licensed to practice in this state, if required by the Florida Building Code,Building for all residential buildings or structures of the same occupancy class. 7. The requirements of Florida Building Code,Existing Building Volume,are also satisfied. 102.2.3 The Building Official shall apply the same standard to a moved residential building or structure as that applied to the remodeling of any comparable residential building or structure to determine whether the moved structure is substantially remodeled.The cost of the foundation on which the moved building or structure is placed shall not be included in the cost of remodeling for purposes of determining whether a moved building or structure has been substantially remodeled. 4 102.2.4 This section does not apply to the jurisdiction and authority of the Department of Agriculture and Consumer Services to inspect amusement rides or the Department of Financial Services to inspect state-owned buildings and boilers. 102.2.5 Each enforcement district or local enforcement agency shall be governed by a board,the composition of which shall be determined by the affected localities. 1.The Village of Tequesta may adopt rules granting to the owner of a single-family residence one or more exemptions from the Florida Building Code relating to: a. Addition,alteration,or repairs performed by the property owner upon his or her own property, provided any addition or alteration or repair shall not exceed 1,000 square feet(93 in')or the square footage of the primary structure,whichever is less. b. Addition, alteration, or repairs by a non-owner within a specific cost limitation set by rule, provided the total cost shall not exceed$5,000 within any 12-month period. c. Building plans review and inspection fees. 2.However, the exemptions under subparagraph 1 do not apply to single-family residences that are located in mapped flood hazard areas, as defined in the code, unless the enforcement district or local enforcement agency has determined that the work, which is otherwise exempt, does not constitute a substantial improvement, including the repair of substantial damage, of such single- family residences. 3.Each code exemption,as defined in sub-subparagraphs 1 a, 1 b, and 1 c shall be certified to the local board 10 days prior to implementation and shall only be effective in the territorial jurisdiction of the enforcement district or local enforcement agency implementing it. 4.However, each enforcement district or local enforcement agency may establish an alternative permitting program for replacing nonstructural components of building systems in a residential dwelling unit. A licensed contractor performing such work for the resident shall also be exempt from individual permits and inspections if either the owner or the licensed contractor obtains a valid Annual Permit per Section 105.1.1 of this code and all such work is reported as required in Section 105.1.2 of this code for compliance evaluation. No added capacity, system expansion or new building work of any type shall be excluded from individual permit and inspection by this provision. 102.2.6 This section does not apply to swings and other playground equipment accessory to a one-or two-family dwelling. Exception: Electrical service to such playground equipment shall be in accordance with Chapter 27 of this code. 102.3 Application of references.References to chapter or section numbers,or to provisions not specifically identified by number, shall be construed to refer to such chapter,section or provision of this code. 102.4 Referenced codes and standards. The codes and standards referenced in this code shall be considered part of the requirements of this code to the prescribed extent of each such reference and as further regulated in Sections 102.4.1 and 102.4.2. 5 102.4.1 Conflicts. Where conflicts occur between provisions of this code and referenced codes and standards,the provisions of this code shall apply. 102.4.2 Provisions in referenced codes and standards. Where the extent of the reference to a referenced code or standard includes subject matter that is within the scope of this code or the Florida Codes listed in Sectionl01.4,the provisions of this code or the Florida Codes listed in Section 101.4,as applicable,shall take precedence over the provisions in the referenced code or standard. 102.5 Partial invalidity. In the event that any part or provision of this code is held to be illegal or void,this shall not have the effect of making void or illegal any of the other parts or provisions. 102.6 Existing structures. The legal occupancy of any structure existing on the date of adoption of this code shall be permitted to continue without change,except as is specifically covered in this code,the Florida Building Code, Existing Building, the Florida Fire Prevention Code, and the provisions of the Village of Tequesta Code of Ordinances Article V,Sec. 14-121, and Appendix B. 102.6.1 Buildings not previously occupied.A building or portion of a building that has not been previously occupied or used for its intended purpose in accordance with the laws in existence at the time of its completion shall comply with the provisions of the Florida Building Code or Florida Residential Code,as applicable,for new construction or with any current permit for such occupancy. 102.6.2 Buildings previously occupied. The legal occupancy of any building existing on the date of adoption of this code shall be permitted to continue without change, except as otherwise specifically provided in this code, the Florida Fire Prevention Code, the Village of Tequesta Code of Ordinances Article V, Sec. 14-121, and Appendix B, or as is deemed necessary by the Building Official for the general safety and welfare of the occupants and the public. 102.7 Relocation of manufactured buildings. 1. Relocation of an existing manufactured building does not constitute an alteration. 2. A relocated building shall comply with wind speed requirements of the new location, using the appropriate wind speed map. If the existing building was manufactured in compliance with the Standard Building Code (prior to March 1, 2002), the wind speed map of the Standard Building Code shall be applicable. If the existing building was manufactured in compliance with the Florida Building Code (after March 1, 2002), the wind speed map of the Florida Building Code shall be applicable. 3. A relocated building shall comply with the flood hazard area requirements of the new location,if applicable. 102.8 Existing mechanical equipment. The Village of Tequesta may not require that existing mechanical equipment located on or above the surface of a roof be installed in compliance with the requirements of the Florida Building Code except during reroofing when the equipment is being replaced or moved during reroofing and is not in compliance with the provisions of the Florida Building Code relating to roof- mounted mechanical units. PART 2—ADMINISTRATION AND ENFORCEMENT SECTION 103 6 DEPARTMENT OF BUILDING SAFETY 103.1 Creation of enforcement agency. The Department of Building Safety is hereby created and the official in charge thereof shall be known as the Building Official. 103.2 Appointment. The Building Official shall be appointed by the chief appointing authority of the jurisdiction. 103.3 Deputies. In accordance with the prescribed procedures of this jurisdiction and with the concurrence of the appointing authority, the Building Official shall have the authority to appoint a deputy Building Official, the related technical officers, inspectors, plan examiners and other employees. Such employees shall have powers as delegated by the Building Official. For the maintenance of existing properties,see the provisions of the Village of Tequesta Code of Ordinances Article V,Sec. 14-121, and Appendix B shall apply to all matters governing property maintenance. 103.4 Restrictions on employees.(Reserved). SECTION 104 DUTIES AND POWERS OF THE BUILDING OFFICIAL 104.1 General. The Building Official is hereby authorized and directed to enforce the provisions of this code. The Building Official shall have the authority to render interpretations of this code and to adopt policies and procedures in order to clarify the application of its provisions. Such interpretations, policies and procedures shall be in compliance with the intent and purpose of this code.Such policies and procedures shall not have the effect of waiving requirements specifically provided for in thiscode. 104.2 Applications and permits. The Building Official shall receive applications, review construction documents and issue permits for the erection,and alteration,demolition and moving of buildings,structures, and service systems, inspect the premises for which such permits have been issued and enforce compliance with the provisions of this code. 104.2.1 Determination of substantially improved or substantially damaged existing buildings and structures in flood hazard areas. For applications for reconstruction,rehabilitation, repair,alteration, addition or other improvement of existing buildings or structures located in flood hazard areas, the Building Official shall determine if the proposed work constitutes substantial improvement or repair of substantial damage. Where the Building Official determines that the proposed work constitutes substantial improvement or repair of substantial damage, and where required by this code,the Building Official shall require the building to meet the requirements of Florida Building Code Section 1612. 104.3 Notices and orders. The Building Official shall issue all necessary notices or orders to ensure compliance with this code. 104.4 Inspections.The Building Official shall make all of the required inspections,or the Building Official shall have the authority to accept reports of inspection by approved agencies or individuals. Reports of such inspections shall be in writing and be certified by a responsible officer of such approved agency or by the responsible individual. The Building Official is authorized to engage such expert opinion as deemed necessary to report upon unusual technical issues that arise, subject to the approval of the appointing authority. 104.5 Identification. The Building Official shall carry proper identification when inspecting structures or premises in the performance of duties under this code. 7 104.6 Right of entry.Where it is necessary to make an inspection to enforce the provisions of this code,or where the Building Official has reasonable cause to believe that there exists in a structure or upon a premises a condition which is contrary to or in violation of this code which makes the structure or premises unsafe, dangerous or hazardous,the Building Official is authorized to enter the structure or premises at reasonable times to inspect or to perform the duties imposed by this code, provided that if such structure or premises be occupied that credentials be presented to the occupant and entry requested.If such structure or premises is unoccupied,the Building Official shall first make a reasonable effort to locate the owner or other person having charge or control of the structure or premises and request entry. If entry is refused, the Building Official shall have recourse to the remedies provided by law to secure entry. 104.7 Department records. The Building Official shall keep official records of applications received, permits and certificates issued, fees collected, reports of inspections, and notices and orders issued. Such records shall be retained in the official records for the period required for retention of public records per Chapter 119,Florida Statutes("Public Records Law"). 104.8 Liability.The Building Official,member of the board of appeals or employee charged with the enforcement of this code,while acting for the jurisdiction in good faith and without malice in the discharge of the duties required by this code or other pertinent law or ordinance, shall not thereby be civilly or criminally rendered liable personally and is hereby relieved from personal liability for any damage accruing to persons or property as a result of any act or by reason of an act or omission in the discharge of official duties. Any suit instituted against an officer, employee, or board member because of an act performed by that officer, employee, or board member in the lawful discharge of duties and under the provisions of this code shall be defended by legal representative of the jurisdiction until the final termination of the proceedings. The Building Official or any subordinate shall not be liable for cost in any action, suit or proceeding that is instituted in pursuance of the provisions of this code. 104.8.1 Legal defense.Any suit or criminal complaint instituted against an officer,employee,or board member because of an act performed by that officer,employee,or board member in the lawful discharge of duties and under the provisions of this code shall be defended by legal representatives of or provided by the Village of Tequesta until the final termination of the proceedings. The Building Official or any subordinate shall not be liable for cost in any action,suit or proceeding that is instituted in pursuance of the provisions of this code. 104.9 Approved materials and equipment.Materials,equipment and devices approved by the Building Official shall be constructed and installed in accordance with such approval. 104.9.1 Used materials and equipment.The use of used materials which meet the requirements of this code for new materials is permitted. Used equipment and devices shall not be reused unless approved by the Building Official. 104.10 Modifications. Wherever there are practical difficulties involved in carrying out the provisions of this code, the Building Official shall have the authority to grant modifications for individual cases, upon application of the owner or owner's representative,provided the Building Official shall first find that special individual reason makes the strict letter of this code impractical and the modification is in compliance with the intent and purpose of this code and that such modification does not lessen health, accessibility,life and fire safety, or structural requirements. The details of action granting modifications shall be recorded and entered in the files of the department of building safety. 104.10.1 Flood hazard areas. The Building Official shall coordinate with the floodplain administrator to review requests submitted to the Building Official that seek approval to modify the strict application 8 of the flood resistant construction requirements of the Florida Building Code to determine whether such requests require the granting of a variance pursuant to Section 117 herein-below. 104.11 Alternative materials, design and methods of construction and equipment. The provisions of this code are not intended to prevent the installation of any material or to prohibit any design or method of construction not specifically prescribed by this code,provided that any such alternative has been approved. An alternative material, design or method of construction shall be approved where the Building Official finds that the proposed design is satisfactory and complies with the intent of the provisions of this code, and that the material, method or work offered is, for the purpose intended,not less than the equivalent of that prescribed in this code in quality, strength, effectiveness, fire resistance, durability and safety. Where the alternative material, design or method of construction is not approved, the Building Official shall respond in writing,stating the reasons why the alternative was not approved. 104.11.1 Research reports. Supporting data, where necessary to assist in the approval of materials or assemblies not specifically provided for in this code, shall consist of valid research reports from approved sources. 104.11.2 Tests. Whenever there is insufficient evidence of compliance with the provisions of this code, or evidence that a material or method does not conform to the requirements of this code, or in order to substantiate claims for alternative materials or methods,the Building Official shall have the authority to require tests as evidence of compliance to be made at no expense to the jurisdiction.Test methods shall be as specified in this code or by other recognized test standards. In the absence of recognized and accepted test methods, the Building Official shall approve the testing procedures. Tests shall be performed by an approved agency. Reports of such tests shall be retained by the Building Official for the period required for retention of public records. 104.12 Requirements not covered by code. Any requirements necessary for strength,stability or proper operation of an existing or proposed building,structure,electrical,gas,mechanical or plumbing system,or for the public safety, health and general welfare, not specifically covered by this or other technical codes, shall be determined by the Building Official. SECTION 105 PERMITS 105.1 Required. Any owner or owner's authorized agent who intends to construct, enlarge, alter, repair, move,demolish,or change the occupancy of a building or structure,or to erect,install,enlarge,alter,repair, remove, convert or replace any impact-resistant coverings, electrical, gas, mechanical or plumbing, fire protection system,or accessible or flood resistant site element,the installation of which is regulated by this code,or to cause any such work to be done,shall first make application to the Building Official and obtain the required permit. 105.1.1 Annual facility permit. In lieu of an individual permit for each alteration to an existing electrical, gas,mechanical or plumbing or interior nonstructural office system(s),the Building Official is authorized to issue an annual permit for any occupancy to facilitate routine or emergency service, repair, refurbishing, minor renovations of service systems or manufacturing equipment installations/relocations. The Building Official shall be notified of major changes and shall retain the right to make inspections at the facility site as deemed necessary. An annual facility permit shall be assessed with an annual fee and shall be valid for one year from date of issuance.A separate permit shall be obtained for each facility and for each construction trade,as applicable.The permit application shall contain a general description of the parameters of work intended to be performed during the year. 105.1.2 Annual Facility permit records. The person to whom an annual permit is issued shall keep a 9 detailed record of alterations made under such annual permit.The Building Official shall have access to such records at all times or such records shall be filed with the Building Official as designated. The Building Official is authorized to revoke such permit if code violations are found to exist. 105.1.3 Food permit. In accordance with 500.12,Florida Statutes, a food permit from the Department of Agriculture and Consumer Services is required of any person who operates a food establishment or retail store. 105.1.4 Public swimming pool. The Village of Tequesta may not issue a building permit to construct, develop, or modify a public swimming pool without proof of application, whether complete or incomplete, for an operating permit pursuant to Section 514.031, Florida Statutes. A certificate of completion or occupancy may not be issued until such operating permit is issued. The Village of Tequesta shall conduct their review of the building permit application upon filing and in accordance with Chapter 553, Florida Statutes. The Village of Tequesta may confer with the Department of Health, if necessary, but may not delay the building permit application review while awaiting comment from the Department of Health. 105.2 Work exempt from permit. Exemptions from permit requirements of this code shall not be deemed to grant authorization for any work to be done in any manner in violation of the provisions of this code or any other laws or ordinances of the Village of Tequesta,to include work in any special flood hazard area. Exemptions granted under this section do not relieve the owner or contractor from their duty to comply with applicable provisions of the Florida Building Code, and requirements of the local floodplain management ordinance. As determined by the Building Official, permits shall not be required for the following: Building: 1.Building permits are not required for replacement or repair work having a value of less than$1,000.00, providing, however, that such work will not adversely affect the structural integrity, fire rating, exit access or egress requirements. 2. Cabinets and countertops with no reconfiguration for 1&2 Family Dwellings,painting,papering, carpeting,and similar finish work,with no electrical or plumbing work. 3.Temporary motion picture,television and theater sets and scenery. 4.Traditional swings and other standard playground equipment accessory to detached one and two-family dwellings,as determined by the Building Official,but they may be subject to Zoning permits. 5. Retractable awnings supported by an exterior wall and do not require additional support of Groups R- 3 and U occupancies,but they may be subject to Zoning permits. 6. Non-fixed and movable fixtures,cases,racks,and counters not over 5 feet 9 inches(1753 mm)in height. Electrical: Repairs and maintenance: Minor repair work, including the replacement of lamps or the connection of approved portable electrical equipment to approved permanently installed receptacles. Radio and television transmitting stations: The provisions of this code shall not apply to electrical equipment used for radio and television transmissions, but do apply to equipment and wiring for a 10 power supply and the installations of towers and antennas. Temporary testing systems:A permit shall not be required for the installation of any temporary system required for the testing or servicing of electrical equipment or apparatus. Gas: 1. Portable heating appliance. 2. Replacement of any minor part that does not alter approval of equipment or make such equipment unsafe. Mechanical: 1.Portable heating appliance. 2.Portable ventilation equipment. 3. Portable cooling unit. 4. Steam,hot or chilled water piping within any heating or cooling equipment regulated by this code. 5.Replacement of any part that does not alter its approval or make it unsafe. 6.Portable evaporative cooler. 7.Self-contained refrigeration system containing 10 pounds(5 kg)or less of refrigerant and actuated by motors of 1 horsepower(746 W)or less. 8. The installation,replacement,removal or metering of any electrical load management control device where installed by a utility service provider. Plumbing: 1. The stopping of leaks in drains, water, soil, waste or vent pipe, provided, however, that if any concealed trap,drain pipe,water,soil,waste or vent pipe becomes defective and it becomes necessary to remove and replace the same with new material, such work shall be considered as new work and a permit shall be obtained and inspection made as provided in this code. 2. The clearing of stoppages or the repairing of leaks in pipes, valves or fixtures and the removal and reinstallation of water closets, provided such repairs do not involve or require the replacement or rearrangement of valves,pipes or fixtures. 3.The replacement of common household plumbing fixtures to existing supply lines and sanitary connections in 1&2 Family Dwellings.This does not include water heaters,bathtubs and showers. 105.2.1 Emergency repairs. Where equipment replacements and repairs must be performed in an emergency situation,the permit application shall be submitted within the next working business day to the Building Official. Notification shall be given to the Building Official, including the work address, nature of emergency,and scope of work immediately,or by the next business day. 105.2.2.Minor repairs. Ordinary minor repairs may be made with the approval of the Building Official 11 without a permit,provided the repairs shall not include the cutting away of any wall,partition or portion thereof,the removal or cutting of any structural beam or load-bearing support,or the removal or change of any required means of egress, or rearrangement of parts of a structure affecting the egress requirements; nor shall ordinary repairs include addition to, alteration of, replacement or relocation of any standpipe, water supply, sewer, drainage, drain leader, gas, soil, waste, vent or similar piping, electric wiring systems or mechanical equipment or other work affecting public health or general safety, and such repairs shall not violate any of the provisions of the technical codes. 105.2.3 Public service agencies. A permit shall not be required for the installation, alteration or repair of generation, transmission, distribution or metering or other related equipment that is under the ownership and control of public service agencies by established right. 105.3 Application for permit.To obtain a permit,the applicant shall first file an application therefore in writing on a form furnished by the Department of Building Safety for that purpose. Permit application forms shall be in the format prescribed by a local administrative board, if applicable, and must comply with the requirements of Section 713.135(5)and(6),Florida Statutes. Each application shall be inscribed with the date of application,and the code in effect as of that date. For a building permit for which an application is submitted prior to the effective date of the Florida Building Code,the state minimum building code in effect in the permitting jurisdiction on the date of the application governs the permitted work for the life of the permit and any extension granted to the permit. Effective October 1, 2017, a local enforcement agency shall post each type of building permit application on its website. Completed applications must be able to be submitted electronically to the appropriate Department of Building Safety.Accepted methods of electronic submission include,but are not limited to, e-mail submission of applications in portable document format or submission of applications through an electronic fill-in form available on the Department of Building Safety's website or through a third-party submission management software. Payments, attachments, or drawings required as part of the permit application may be submitted in person in a non-electronic format,at the discretion of the Building Official. 105.3.1 Action on application. The Building Official shall examine or cause to be examined applications for permits and amendments thereto within a reasonable time after filing. If the application or the construction documents do not conform to the requirements of pertinent laws, the Building Official shall reject such application in writing, stating the reasons therefore. If the Building Official is satisfied that the proposed work conforms to the requirements of this code and laws and ordinances applicable thereto, the Building Official shall issue a permit therefore as soon as practicable. When authorized through contractual agreement with a school board,in acting on applications for permits,the Building Official shall give first priority to any applications for the construction of, or addition or renovation to,any school or educational facility. 105.3.1.1 If a state university,Florida college or public school district elects to use a local government's code enforcement offices, fees charged by counties and municipalities for enforcement of the Florida Building Code on buildings, structures, and facilities of state universities, state colleges, and public school districts shall not be more than the actual labor and administrative costs incurred for plans review and inspections to ensure compliance with the code. 105.3.1.2 No permit may be issued for any building construction, erection, alteration, modification, repair, or addition unless the applicant for such permit provides to the enforcing agency which issues the permit any of the following documents which apply to the construction for which the permit is to be issued and which shall be prepared by or under the direction of an engineer registered under Chapter 12 471,Florida Statutes: 1.Plumbing documents for any new building or addition which requires a plumbing system with more than 250 fixture units or which costs more than$125,000. 2.Fire sprinkler documents for any new building or addition,which includes a fire sprinkler system, which contains 50 or more sprinkler heads.Personnel as authorized by chapter 633 Florida Statutes, may design a new fire protection system of 49 or fewer sprinklers; and may design the alteration of an existing fire sprinkler system if the alteration consists of the relocation, addition or deletion of 49 or fewer sprinklers,notwithstanding the size of the existing fire sprinkler system. 3.Heating, ventilation, and air-conditioning documents for any new building or addition, which requires more than a 15-ton-per-system capacity which is designed to accommodate 100 or more persons or for which the system costs more than $125,000. This paragraph does not include any document for the replacement or repair of an existing system in which the work does not require altering a structural part of the building or for work on a residential one,two,three or four-family structure. An air-conditioning system may be designed by an installing air-conditioning contractor certified under Chapter 489, Florida Statutes, to serve any building or addition which is designed to accommodate fewer than 100 persons and requires an air-conditioning system with a value of $125,000 or less;and when a 15-ton-per system or less is designed for a singular space of a building and each 15-ton system or less has an independent duct system. Systems not complying with the above require design documents that are to be sealed by a professional engineer. Example 1: When a space has two 10-ton systems with each having an independent duct system, the contractor may design these two systems since each unit(system)is less than 15 tons. Example 2: Consider a small single-story office building which consists of six individual offices where each office has a single three-ton package air conditioning heat pump.The six heat pumps are connected to a single water cooling tower.The cost of the entire heating, ventilation and air- conditioning work is $47,000 and the office building accommodates fewer than 100 persons. Because the six mechanical units are connected to a common water tower this is considered to be an 18-ton system. NOTE: It was further clarified by the Commission that the limiting criteria of 100 persons and $125,000 apply to the building occupancy load and the cost for the total air-conditioning system of the building. 4.Any specialized mechanical, electrical, or plumbing document for any new building or addition which includes a medical gas, oxygen, steam,vacuum,toxic air filtration, halon, or fire detection and alarm system which costs more than$5,000. 5.Electrical documents. See Florida Statutes 471.003(2)(h). Any electrical or plumbing or air conditioning and refrigeration system meeting the following thresholds are required to be designed by a Florida Registered Engineer.Any system which: 1.Requires an electrical or plumbing or air-conditioning and refrigeration system with a value greater than$125,000;and 2. a. Requires an aggregate service capacity of greater than 600 amperes (240 volts) on a residential electrical system or greater than 800 amperes (240 volts) on a commercial or industrial electrical system; 13 b.Requires a plumbing system with more than 250 fixture units;or c. Requires a heating, ventilation, and air-conditioning system which exceeds a 15-ton-per- system capacity, or if the project is designed to accommodate more than 100 persons. Documents requiring an engineer seal by this part shall not be valid unless a professional engineer who possess a valid certificate of registration has signed,dated,and stamped such document as provided in Section 471.025,Florida Statutes. 6.All public swimming pools and public bathing places defined by and regulated under Chapter 514, Florida Statutes. 105.3.2 Time limitation of application. An application for a permit for any proposed work shall be deemed to have been abandoned becoming null and void 180 days after the date of filing,or for any 180 day period of abandonment or suspension during the application process, unless such application has been pursued in good faith or a permit has been issued; except that the Building Official is authorized to grant one or more extensions of time for additional periods not exceeding 90 days each.The extension shall be requested in writing prior to the abandonment date, with justifiable cause demonstrated. Abandoned applications shall be subject to destruction in accordance with state law.The fee for renewal, re-issuance, and extension of a permit application shall be set forth by the Village of Tequesta Village Council. There may be fees or requirements from other government agencies for permit application extensions and renewals. 105.3.3 An enforcing authority may not issue a building permit for any building construction,erection, alteration, modification, repair or addition unless the permit either includes on its face or there is attached to the permit the following statement:"NOTICE:In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, such as the requirement for Home or Property Owners Association approval, and there may be additional permits required from other governmental entities such as water management districts, state agencies,or federal agencies." 105.3.4 A building permit for a single-family residential dwelling must be issued within 30 working days of application therefore unless unusual circumstances require a longer time for processing the application or unless the permit application fails to satisfy the Florida Building Code or the enforcing agency's laws or ordinances. 105.3.5 Identification of minimum premium policy. Except as otherwise provided in Chapter 440, Florida Statutes, Workers' Compensation, every employer shall, as a condition to receiving a building permit, show proof that it has secured compensation for its employees as provided in Section 440.10 and 440.38,Florida Statutes. 105.3.6 Asbestos removal contractor exemption. Refer to Section 105.9 herein-below for additional requirements.A licensed asbestos removal contractor is not required when moving,removal or disposal of asbestos-containing materials on a residential building where the owner occupies the building, the building is not for sale or lease, and the work is performed according to the owner-builder limitations provided in this paragraph. To qualify for exemption under this paragraph, an owner must personally appear and sign the building permit application. The permitting agency shall provide the person with a disclosure statement in substantially the following form: Disclosure Statement: State law requires asbestos abatement to be done by licensed contractors. You have applied for a permit under an exemption to that law.The exemption allows you, as the owner of your property,to act as your own asbestos abatement contractor even though you do not have a license.You must supervise the construction yourself. You may move,remove or dispose 14 of asbestos-containing materials on a residential building where you occupy the building and the building is not for sale or lease,or the building is a farm outbuilding on your property. If you sell or lease such building within 1 year after the asbestos abatement is complete,the law will presume that you intended to sell or lease the property at the time the work was done,which is a violation of this exemption.You may not hire an unlicensed person as your contractor. Your work must be done according to all local, state and federal laws and regulations, which apply to asbestos abatement projects. It is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. 105.3.7 Applicable Code for Manufactured Buildings. Manufacturers should be permitted to complete all buildings designed and approved prior to the effective date of a new code edition,provided a clear signed contract is in place.The contract shall provide specific data mirroring that required by an application for permit, specifically,without limitation,date of execution,building owner or dealer,and anticipated date of completion. However,the construction activity must commence within 6 months of the contract's execution. The contract is subject to verification by the Department of Business and Professional Regulation. 105.3.8 Contract. The Village of Tequesta shall not require a contract between a builder and an owner for the issuance of a building permit or as a requirement for the submission of a building permit application. 105.3.9 Public right of way. A permit shall not be given by the Building Official for the construction of any building, or for the alteration of any building where said building is to be changed and such change will affect the exterior walls,bays,balconies,or other appendages or projections fronting on any street,alley or public lane,or for the placing on any lot or premises of any building or structure removed from another lot or premises,unless the applicant has received a right of way permit from the authority having jurisdiction over the street,alley or public lane. 105.4 Conditions of the permit.The issuance or granting of a permit shall not be construed to be a permit for,or an approval of, any violation of any of the provisions of this code or of any other ordinance of any other federal,state and local laws, ordinances, codes and regulations. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of any other federal,state and local laws, ordinances, codes and regulations shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. The Building Official is also authorized to prevent occupancy or use of a structure where in violation of this code or of any other ordinances of this jurisdiction or of any other federal,state and local laws,ordinances,codes and regulations. 105.4.1 Permit intent.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter or set aside any of the provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of this code. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months after its issuance,or if the work authorized by such permit is suspended or abandoned for a period of six months after the time the work is commenced. 105.4.1.1 If work has commenced and the permit is revoked, becomes null and void, or expires because of lack of progress or abandonment, a new permit covering the proposed construction shall be obtained before proceeding with the work. 105.4.1.2 If a new permit,or revalidation(renewal)of the original permit,is not obtained within 180 15 days from the date the initial permit became null and void, the Building Official is authorized to require that any work which has been commenced or completed be removed from the building site. Alternately,a new permit may be issued on application,providing the work in place and required to complete the structure meets all applicable regulations in effect at the time the initial permit became null and void and any regulations which may have become effective between the date of expiration and the date of issuance of the new permit. 105.4.1.3 Work shall be considered to be in active progress when the permit has received an approved inspection within 180 days.This provision shall not be applicable in case of civil commotion or strike or when the building work is halted due directly to judicial injunction, order or similar process, or due to action by an environmental or archeological agency having jurisdiction.The Building Official is authorized to grant,in writing,one or more extensions of time,for periods not more than 3 months each. The extension shall be requested in writing and justifiable cause demonstrated, prior to expiration. 105.4.1.4 The fee for renewal, reissuance and extension of a permit shall be set forth by the administrative authority. There may be fees or requirements from other government agencies for permit extensions and renewals. 105.4.1.5 Any building permit work that has not received a certificate of occupancy or certificate of completion within two years from the date of original issuance shall be considered expired. If a new building permit is not obtained in accordance with section 105.4.1.2 herein, within 30 days of the expiration of the expired building permit, the construction shall be subject to unsafe structure abatement proceedings. 105.4.2 Additional options for closing a permit. Pursuant to Section 553.79(15), Florida Statutes, a property owner,regardless of whether the property owner is the one listed on the application for the building permit,may close a building permit by complying with the following requirements: 1. The property owner may retain the original contractor listed on the permit or hire a different contractor appropriately licensed in this state to perform the work necessary to satisfy the conditions of the permit and to obtain any necessary inspection in order to close the permit. If a contractor other than the original contractor listed on the permit is hired by the property owner to close the permit, such contractor is not liable for any defects in the work performed by the original contractor and is only liable for the work that he or she performs. 2. The property owner may assume the role of an owner-builder,in accordance with Sections 489.103(7)and 489.503(6),Florida Statutes. 3. If a building permit is expired and its requirements have been substantially completed as determined by the local enforcement agency,the permit may be closed without having to obtain a new building permit, and the work required to close the permit may be done pursuant to the building code in effect at the time the Village of Tequesta received the application for the permit, unless the contractor has sought and received approval from the Village of Tequesta for an alternative material, design or method of construction. 4. The Village of Tequesta may close a building permit 6 years after the issuance of the permit, even in the absence of a final inspection, if the Village of Tequesta determines that no apparent safety hazard exists. For purposes of this section,the term"close"means that the requirements of the permit have been satisfied. 16 105.5 Expiration.Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance,or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Building Official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each.The extension shall be requested in writing and justifiable cause demonstrated as determined by the Building Official. 105.6 Denial or revocation. Whenever a permit required under this section is denied or revoked because the plan,or the construction,erection,alteration,modification,repair,or demolition of a building, is found by the Village of Tequesta to be not in compliance with the Florida Building Code,the Village of Tequesta shall identify the specific plan or project features that do not comply with the applicable codes,identify the specific code chapters and sections upon which the finding is based, and provide this information to the permit applicant. If the local building code administrator or inspector finds that the plans are not in compliance with the Florida Building Code,the local building code administrator or inspector shall identify the specific plan features that do not comply with the applicable codes, identify the specific code chapters and sections upon which the finding is based,and provide this information to the Village of Tequesta. The Village of Tequesta shall provide this information to the permit applicant. Pursuant to Section 553.79(16), Florida Statutes, the Village of Tequesta may not deny issuance of a building permit to; issue a notice of violation to; or fine,penalize sanction or assess fees against an arm's- length purchaser of a property for value solely because a building permit applied for by a previous owner of the property was not closed. The Village of Tequesta shall maintain all rights and remedies against the property owner and contractor listed on the permit. Pursuant to Section 553.79(16), Florida Statutes, the Village of Tequesta may not deny issuance of a building permit to a contractor solely because the contractor is listed on other building permits that were not closed. 105.6.1 Misrepresentation of application. The Building Official may revoke a permit or approval, issued under the provisions of this code, when there has been any false statement or misrepresentation as to the material fact in the application or plans on which the permit or approval was based. 105.6.2 Violation of code provisions.The Building Official may require correction or revoke the permit upon determination by the Building Official that the construction, erection, alteration, repair, moving, demolition, installation, or replacement of the building, structure, electrical, gas, mechanical or plumbing systems for which the permit was issued is in violation of, or not in conformity with, the provisions of this code or the Village of Tequesta Code of Ordinances. 105.7 Placement of permit. The building permit or a copy shall be kept on the site of the work until the completion of the project. 105.8 Notice of commencement. In accordance with Section 713.135, Florida Statutes, when any person applies for a building permit,the authority issuing such permit shall print on the face of each permit card in no less than 14-point, capitalized, boldfaced type: "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." 105.9 Asbestos.The Village of Tequesta shall require each building permit for the demolition or renovation of an existing structure to contain an asbestos notification statement which indicates the owner's or 17 operator's responsibility to comply with the provisions of Section 469.003, Florida Statutes, and to notify the Department of Environmental Protection of his or her intentions to remove asbestos,when applicable, in accordance with state and federal law. Refer to Section 105.3.6 "Asbestos Removal Contractor Exemption"of this code for additional requirements. 105.10 Certificate of protective treatment for prevention of termites. A weather-resistant job-site posting board shall be provided to receive duplicate treatment certificates as each required protective treatment is completed, providing a copy for the person the permit is issued to and another copy for the building permit files. The treatment certificate shall provide the product used, identity of the applicator, time and date of the treatment,site location,area treated,chemical used,percent concentration and number of gallons used,to establish a verifiable record of protective treatment. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall be completed prior to final building approval. For a bait system, see Section 1816.1.7 of the Florida Building Code for contract document requirements. 105.11 Notice of termite protection.A permanent sign which identifies the termite treatment provider and need for reinspection and treatment contract renewal shall be provided. The sign shall be posted near the water heater or electric panel. 105.12 Work starting before permit issuance.Upon written request and approval of the Building Official, the scope of work delineated in the building permit application and plan may be started prior to the final approval and issuance of the permit,provided any work completed is entirely at risk of the permit applicant and the work does not proceed past the first required inspection. 105.13 Phased permit approval.After submittal of the appropriate construction documents,the Building Official is authorized to issue a permit for the construction of foundations or any other part of a building or structure before the construction documents for the whole building or structure have been submitted. The holder of such permit for the foundation or other parts of a building or structure shall proceed at the holder's own risk with the building operation and without assurance that a permit for the entire structure will be granted. Corrections may be required to meet the requirements of the technical codes. 105.14 Permit issued on basis of an affidavit. The Building Official may accept a sworn affidavit from a registered architect or engineer stating that the plans submitted conform to the technical codes. For buildings and structures, the affidavit shall state that the plans conform to the laws as to egress, type of construction and general arrangement and,if accompanied by drawings,show the structural design and that the plans and design conform to the requirements of the technical codes as to strength, stresses, strains, loads and stability. Whenever a permit is issued in reliance upon an affidavit or whenever the work to be covered by a permit involves installation under conditions, which, in the opinion of the Building Official, are hazardous or complex,the Building Official shall require that the architect or engineer who signed the affidavit or prepared the drawings or computations shall supervise such work. In addition, they shall be responsible for conformity to the permit,provide copies of inspection reports as inspections are performed, and upon completion make and file with the Building Official written affidavit that the work has been done in conformity to the reviewed plans and with the structural provisions of the technical codes. In the event such architect or engineer is not available,the owner shall employ in his stead a competent person or agency whose qualifications are reviewed by the Building Official. The Building Official shall ensure that any person conducting plans review is qualified as a plans examiner under Part XII of Chapter 468, Florida Statutes, and that any person conducting inspections is qualified as a building inspector under Part III of Chapter 468,Florida Statutes.Nothing aforesaid shall preclude plan review or inspections by the Building Official (See also Section 107.6). Exception: Permits issued on basis of an affidavit shall not extend to the flood load and flood resistance requirements of the Florida Building Code and the Building Official shall review and inspect those 18 requirements. 105.15 Opening protection. When any activity requiring a building permit that is applied for on or after July 1, 2008, and for which the estimated cost is $50,000 or more for a site built single-family detached residential structure that is located in the wind borne debris region as defined in this Code and that has an insured value of $750,000 or more, or, if the site built single-family detached residential structure is uninsured or for which documentation of insured value is not presented,has a just valuation for the structure for purposes of ad valorem taxation of$750,000 or more;opening protections as required within this Code or Florida Building Code,Residential for new construction shall be provided. Exception: Where defined wind-borne debris regions have not changed, single family detached residential structures permitted subject to the Florida Building Code are not required to comply with this section. 105.16 Inspection of existing residential building not impacted by construction. (a)A Village of Tequesta,and any local building code administrator,inspector,or other official or entity, may not require as a condition of issuance of a one- or two-family residential building permit the inspection of any portion of a building, structure, or real property that is not directly impacted by the construction, erection, alteration, modification, repair, or demolition of the building, structure, or real property for which the permit is sought. (b)This subsection does not apply to a building permit sought for: 1. A substantial improvement as defined in Section 161.54, Florida Statutes or as defined in the Florida Building Code. 2. A change of occupancy as defined in the Florida BuildingCode. 3. A conversion from residential to nonresidential or mixed use pursuant to Section553.507(2)(a), Florida Statutes or as defined in the Florida Building Code. 4. A historic building as defined in the Florida Building Code. (c) This subsection does not prohibit a Village of Tequesta, or any local building code administrator, inspector,or other official or entity,from: 1. Citing any violation inadvertently observed in plain view during the ordinary course of an inspection conducted in accordance with the prohibition in paragraph(a). 2. Inspecting a physically nonadjacent portion of a building, structure, or real property that is directly impacted by the construction, erection, alteration,modification,repair,or demolition of the building, structure, or real property for which the permit is sought in accordance with the prohibition in paragraph(a). 3. Inspecting any portion of a building, structure, or real property for which the owner or other person having control of the building, structure,or real property has voluntarily consented to the inspection of that portion of the building, structure, or real property in accordance with the prohibition in paragraph(a). 4. Inspecting any portion of a building,structure,or real property pursuant to an inspection warrant issued in accordance with Sections 933.20-933.30,Florida Statutes. 105.17 Streamlined low-voltage alarm system installation permitting. 19 (1)As used in this section,the term: (a) "Contractor" means a person who is qualified to engage in the business of electrical or alarm system contracting pursuant to a certificate or registration issued by the department under part II of chapter 489,Florida Statutes. (b) "Low-voltage alarm system project" means a project related to the installation, maintenance, inspection,replacement,or service of a new or existing alarm system,as defined in Section 489.505, Florida Statutes, including video cameras and closed-circuit television systems used to signal or detect a burglary,fire,robbery,or medical emergency,that is hardwired and operating at low voltage, as defined in the National Electrical Code Standard 70, current edition, or a new or existing low- voltage electric fence.The term also includes ancillary components or equipment attached to a low- voltage alarm system, or low-voltage electric fence, including, but not limited to,home-automation equipment, thermostats, closed-circuit television systems, access controls, battery recharging devices,and video cameras. (c)"Low-voltage electric fence"means an alarm system, as defined in s. 489.505,that consists of a fence structure and an energizer powered by a commercial storage battery not exceeding 12 volts which produces an electric charge upon contact with the fence structure. (d)"Wireless alarm system"means a burglar alarm system or smoke detector that is not hardwired (2) Notwithstanding any provision of this Code, this section applies to all low-voltage alarm system projects for which a permit is required by a local enforcement agency.However,a permit is not required to install, maintain, inspect, replace, or service a wireless alarm system, including any ancillary components or equipment attached to the system. 1. A low-voltage electric fence must meet all of the following requirements to be permitted as a low- voltage alarm system project and no further permit shall be required for the low-voltage alarm system project other than as provided in this section: (a) The electric charge produced by the fence upon contact must not exceed energizer characteristics set forth in paragraph 22.108 and depicted in Figure 102 of International Electrotechnical Commission Standard No.60335-2-76,Current Edition. (b) A nonelectric fence or wall must completely enclose the low-voltage electric fence.The low- voltage electric fence may be up to 2 feet higher than the perimeter nonelectric fence or wall. (c) The low-voltage electric fence must be identified using warning signs attached to the fence at intervals of not more than 60 feet. (d) The low-voltage electric fence shall not be installed in an area zoned exclusively for single- family or multi-family residential use. (e) The low-voltage electric fence shall not enclose the portions of a property which are used for residential purposes. (4) This section does not apply to the installation or replacement of a fire alarm if a plan review is required. (5)The Village of Tequesta shall make uniform basic permit labels available for purchase by a contractor to be used for the installation or replacement of a new or existing alarm system at a cost as indicated in Section 553.793,Florida Statutes.The Village of Tequesta may not require the payment of any additional fees,charges,or expenses associated with the installation or replacement of a new or existingalarm. 20 (a) The Village of Tequesta may not require a contractor, as a condition of purchasing a label, to submit information other than identification information of the licensee and proof of registration or certification as a contractor. (b)A label is valid for 1 year after the date of purchase and may only be used within the jurisdiction of the local enforcement agency that issued the label. A contractor may purchase labels in bulk for one or more unspecified current or future projects. (6)A contractor shall post an unused uniform basic permit label in a conspicuous place on the premises of the low-voltage alarm system project site before commencing work on the project. (7)A contractor is not required to notify the local enforcement agency before commencing work on a low-voltage alarm system project. However, a contractor must submit a Uniform Notice of a Low- Voltage Alarm System Project as provided under subsection(7)to the local enforcement agency within 14 days after completing the project.A local enforcement agency may take disciplinary action against a contractor who fails to timely submit a Uniform Notice of a Low-Voltage Alarm System Project. (8)The Uniform Notice of a Low-Voltage Alarm System Project may be submitted electronically or by facsimile if all submissions are signed by the owner,tenant, contractor, or authorized representative of such persons. The Uniform Notice of a Low-Voltage Alarm System Project shall be in the format prescribed by the local enforcement agency and must comply with the requirements of Section 553.793(7),Florida Statutes. (9)The Village of Tequesta may coordinate directly with the owner or customer to inspect a low-voltage alarm system project may be inspected by the local enforcement agency to ensure compliance with applicable codes and standards. If a low-voltage alarm system project fails an inspection,the contractor must take corrective action as necessary to pass inspection. (10)The Village of Tequesta shall not adopt or maintain in effect any ordinance or rule regarding a low- voltage alarm system project that is inconsistent with this section. (11)A uniform basic permit label shall not be required for the subsequent maintenance, inspection, or service of an alarm system that was permitted in accordance with this section.The provisions of this act are not intended to impose new or additional licensure requirements on persons licensed in accordance with the applicable provisions of chapter 489,Florida Statutes. SECTION 106 FLOOR AND ROOF DESIGN LOADS 106.1 Live loads posted. Where the live loads for which each floor or portion thereof of a commercial or industrial building is or has been designed to exceed 50 psf(2.40 kN/m2), such design live loads shall be conspicuously posted by the owner or the owner's authorized agent in that part of each story in which they apply,using durable signs. It shall be unlawful to remove or deface such notices 106.2 Issuance of certificate of occupancy. A certificate of occupancy required by Section 1 I 1 shall not be issued until the floor load signs,required by Section 106.1,have been installed. 106.3 Restrictions on loading. It shall be unlawful to place,or cause or permit to be placed,on any floor or roof of a building,structure or portion thereof,a load greater than is permitted by this code. SECTION 107 SUBMITTAL DOCUMENTS 21 107.1 General. Submittal documents consisting of construction documents, statement of special inspections, geotechnical report and other data shall be submitted in two or more sets with each permit application in accordance with Florida Statute 553.79. The construction documents shall be prepared by a registered design professional where required by Chapter 471, Florida Statutes & 61G15 Florida Administrative Code or Chapter 481,Florida Statutes&61G1 Florida Administrative Code.Where special conditions exist, the Building Official is authorized to require additional construction documents to be prepared by a registered design professional.Electronic media documents shall be submitted when required by the Building Official, in a format acceptable to the Building Official, and may require only one set of submittals. Exception: The Building Official is authorized to waive the submission of construction documents and other data not required to be prepared by a registered design professional if it is found that the nature of the work applied for is such that review of construction documents is not necessary to obtain compliance with this code. If the design professional is an architect, interior designer, or engineer legally registered under the laws of this state regulating the practice of architecture or interior design as provided for in Chapter 481, Florida Statutes, Part I, or landscape architecture as provided for in Chapter 481, Florida Statutes, Part II, or engineering as provided for in Chapter 471, Florida Statutes, then he or she shall affix his or her official seal to said drawings,specifications and accompanying data,as required by Florida Statutes. 107.2 Construction documents.Construction documents shall be in accordance with Sections 107.2.1 through 107.2.6. 107.2.1 Information on construction documents. Construction documents shall be dimensioned and drawn upon suitable material. Electronic media documents are permitted to be submitted when approved by the Building Official. Construction documents shall be of sufficient clarity to indicate the location,nature and extent of the work proposed and show in detail that it will conform to the provisions of this code and relevant laws,ordinances,rules and regulations,as determined by the Building Official. Such drawings and specifications shall contain information, in the form of notes or otherwise, as to the quality of materials, where quality is essential to conformity with the technical codes. Such information shall be specific,and the technical codes shall not be cited as a whole or in part, nor shall the term "legal" or its equivalent be used as a substitute for specific information. All information, drawings, specifications and accompanying data shall bear the name and signature of the person responsible for the design. 107.2.1.1 For roof assemblies required by the code, the construction documents shall illustrate, describe and delineate the type of roofing system, materials, fastening requirements, flashing requirements and wind resistance rating that are required to be installed. Product evaluation and installation shall indicate compliance with the wind criteria required for the specific site or a statement by an architect or engineer certifying suitability for the specific site must be submitted with the construction documents. 107.2.1.2 Additional data.The Building Official may require details,computations,stress diagrams, and other data necessary to describe the construction or installation and the basis of calculations.All drawings, specifications and accompanying data required by the Building Official to be prepared by an architect or engineer shall be affixed with their official seal, signature and date as state law requires. 22 107.2.1.3 Quality of building plans. Building plans shall be drawn to a minimum 1/8 inch scale upon substantial paper, cloth or other acceptable medium. The Building Official may establish, through Departmental policy, other standards for plans and specifications, including electronic format, in order to provide conformity to its electronic permit review and record retention program. This policy may include such things as minimum size, shape,contrast,clarity,or other items related to records management. Electronic media must be compatible with the archive requirements of Florida Statutes. 107.2.2 Fire protection system shop drawings. Shop drawings for the fire protection system(s) shall be submitted to indicate conformance to this code and the construction documents and shall be approved prior to the start of system installation. Shop drawings shall contain all information as required by the referenced installation standards in Chapter 9 of the Florida Building Code. 107.2.3 Means of egress. The construction documents shall show in sufficient detail the location, construction, size and character of all portions of the means of egress including the path of the exit discharge to the public way in compliance with the provisions of this code.In other than occupancies in Groups R-2, R-3, and I-1, the construction documents shall designate the number of occupants to be accommodated on every floor,and in all rooms and spaces. 107.2.4 Exterior wall envelope. Construction documents for all buildings shall describe the exterior wall envelope in sufficient detail to determine compliance with this code.The construction documents shall provide details of the exterior wall envelope as required, including flashing, intersections with dissimilar materials, corners, end details, control joints, intersections at roof, eaves or parapets, means of drainage,water-resistive membrane and details around openings. The construction documents shall include manufacturer's installation instructions that provide supporting documentation that the proposed penetration and opening details described in the construction documents maintain the weather resistance of the exterior wall envelope. The supporting documentation shall fully describe the exterior wall system which was tested,where applicable,as well as the test procedure used. 107.2.5 Exterior balcony and elevated walling surfaces. Where balcony or other elevated walking surfaces are exposed to water from direct or blowing rain, snow or irrigation,and the structural framing is protected by an impervious moisture barrier the construction documents shall include details for all element of the impervious moisture barrier system. The construction documents shall include manufacturer's installation instructions.(CA7834) 107.2.6 Site plan. The construction documents submitted with the application for permit shall be accompanied by a site plan showing to scale the size and location of new construction and existing structures on the site, distances from lot lines, the established street grades and the proposed finished grades and, as applicable, flood hazard areas, floodways, and design flood elevations; and it shall be drawn in accordance with an accurate boundary line survey. In the case of demolition,the site plan shall show construction to be demolished and the location and size of existing structures and construction that are to remain on the site or plot.The Building Official is authorized to waive or modify the requirement for a site plan when the application for permit is for alteration or repair or when otherwise warranted. 107.2.6.1 Design flood elevations. Where design flood elevations are not specified, they shall be established in accordance with Section 1612.3.1. Design flood elevations shall be uniformly specified utilizing the currently effective NAVD 88. 23 107.2.6.2 For the purpose of inspection and record retention, site plans for a building may be maintained in the form of an electronic copy at the worksite.These plans must be open to inspection by the Building Official or a duly authorized representative,as required by the Florida Building Code. 107.2.7 Structural information. The construction documents shall provide the information specified in Section 1603. 107.3 Examination of documents. The Building Official shall examine or cause to be examined the accompanying submittal documents and shall ascertain by such examinations whether the construction indicated and described is in accordance with the requirements of this code and other pertinent laws or ordinances. Exceptions: 1. Building plans approved pursuant to Section 553.77(5), Florida Statutes, and state-approved manufactured buildings are exempt from local codes Village of Tequesta plan reviews except for provisions of the code relating to erection, assembly or construction at the site. Erection, assembly and construction at the site are subject to local permitting and inspections. Photocopies of plans approved according to FAC 61-41.009, Florida Administrative Code, shall be sufficient for Village of Tequesta permit application documents of record for the modular building portion of the permitted project. 2. Industrial construction on sites where design, construction and fire safety are supervised by appropriately licensed design and inspection professionals and which contain adequate in-house fire departments and rescue squads is exempt, subject to approval by the Building Official, from review of plans and inspections, providing the appropriate licensed design and inspection professionals certify that applicable codes and standards have been met and supply appropriate approved drawings to local building and fire-safety inspectors. 107.3.1 Approval of construction documents. When the Building Official issues a permit, the construction document shall be approved,in writing or by stamp,as "Reviewed for Code Compliance." One set of construction documents so reviewed shall be retained by the Building Official.The other set shall be returned to the applicant,shall be kept at the site of work and shall be open to inspection by the Building Official or a duly authorized representative. 107.3.2 Previous approvals. This code shall not require changes in the construction documents, construction or designated occupancy of a structure for which a lawful permit has been heretofore issued or otherwise lawfully authorized, and the construction of which has been pursued in good faith within 180 days after the effective date of this code and has not been abandoned. 107.3.3 Phased approval. The Building Official is authorized to issue a permit for the construction of foundations or any other part of a building or structure before the construction documents for the whole building or structure have been submitted, provided that adequate information and detailed statements have been filed complying with pertinent requirements of this code. The holder of such permit for the foundation or other parts of a building or structure shall proceed at the holder's own risk with the building operation and without assurance that a permit for the entire structure will be granted. 107.3.4 Design professional in responsible charge. Where it is required that documents be prepared by a registered design professional,the Building Official shall be authorized to require the owner or the owner's authorized agent to engage and designate on the building permit application a registered design 24 professional who shall act as the registered design professional in responsible charge. If the circumstances require,the owner or the owner's authorized agent shall designate a successor registered design professional in responsible charge who shall perform the duties required of the original registered design professional in responsible charge.The Building Official shall be notified in writing by the owner or the owner's authorized agent if the registered design professional in responsible charge is changed or is unable to continue to perform the duties. Successor registered design professional in responsible charge licensed under Chapter 471 Florida Statutes shall comply with Section 471.025(4)Florida Statute and the procedure set forth in 61 G 15-27.001 Florida Administrative Code; or licensed under Chapter 481 Florida Statutes shall comply with Section 481.221(6)Florida Statute and the procedure set forth in 61G1-18.002 Florida Administrative Code. The registered design professional in responsible charge shall be responsible for reviewing and coordinating submittal documents prepared by others, including phased and deferred submittal items, for compatibility with the design of the building. Those products which are regulated by FAC Rule 61G20 shall be reviewed and approved in writing by the designer of record prior to submittal for jurisdictional approval. 107.3.4.1 Deferred submittals. For the purposes of this section, deferred submittals are defined as those portions of the design that are not submitted at the time of the application and that are to be submitted to the Building Official. Deferral of any submittal items shall have the prior approval of the Building Official.The registered design professional in responsible charge shall list the deferred submittals on the construction documents for review by the Building Official. Documents for deferred submittal items shall be submitted to the registered design professional in responsible charge who shall review them and forward them to the Building Official with a notation indicating that the deferred submittal documents have been reviewed and found to be in general conformance to the design of the building. The deferred submittal items shall not be installed until the deferred submittal documents have been approved by the Building Official. 107.3.4.2 Certifications by contractors authorized under the provisions of Section 489.115(4)(b), Florida Statutes, shall be considered equivalent to sealed plans and specifications by a person licensed under Chapter 471,Florida Statutes,or Chapter 481 Florida Statutes,by local enforcement agencies for plans review for permitting purposes relating to compliance with the wind-resistance provisions of the code or alternate methodologies approved by the Florida Building Commission for one- and two-family dwellings. Local enforcement agencies may rely upon such certification by contractors that the plans and specifications submitted conform to the requirements of the code for wind resistance. Upon good cause shown, local government code enforcement agencies may accept or reject plans sealed by persons licensed under Chapters 471,481 or 489,Florida Statutes. 107.3.5 Minimum plan review criteria for buildings. The examination of the documents by the Building Official shall include the following minimum criteria and documents: a floor plan; site plan; foundation plan; floor/roof framing plan or truss layout; all fenestration and building envelope penetrations;flashing;and rough opening dimensions;and all exterior elevations: Commercial Buildings: Building 1. Site requirements: Parking 25 Fire access Vehicle loading Driving/turning radius Fire hydrant/water supply/post indicator valve(PIV) Set back/separation(assumed property lines) Location of specific tanks,water lines and sewer lines Flood hazard areas,flood zones,and design flood elevations 2.Occupancy group and special occupancy requirements shall be determined(with cross check with the energy code submittal). 3.Minimum type of construction shall be determined(see Table 503). 4. Fire-resistant construction requirements shall include the following components: Fire-resistant separations Fire-resistant protection for type of construction Protection of openings and penetrations of rated walls Fire blocking and draftstopping and calculated fire resistance 5. Fire suppression systems shall include: Early warning smoke evacuation systems Schematic fire sprinklers Standpipes Pre-engineered systems Riser diagram 6. Life safety systems shall be determined and shall include the following requirements: Occupant load and egress capacities Early warning Smoke control Stair pressurization Systems schematic 7. Occupancy load/egress requirements shall include: Occupancy load Gross Net Means of egress Exit access Exit Exit discharge Stairs construction/geometry and protection Doors Emergency lighting and exit signs Specific occupancy requirements Construction requirements Horizontal exits/exit passageways 8. Structural requirements shall include: Soil conditions/analysis Termite protection 26 Design loads Wind requirements Building envelope Impact resistant coverings or systems Structural calculations(if required) Foundation Flood requirements in accordance with Section 1612,including lowest floor elevations,enclosures, flood damage-resistant materials Wall systems Floor systems Roof systems Threshold inspection plan Stair systems 9. Materials shall be reviewed and shall at a minimum include the following: Wood Steel Aluminum Concrete Plastic Glass Masonry Gypsum board and plaster Insulating(mechanical) Roofing Deck coatings Insulation Building envelope portions of the Energy Code(including calculation and mandatory requirements) 10.Accessibility requirements shall include the following: Site requirements Accessible route Vertical accessibility Toilet and bathing facilities Drinking fountains Equipment Special occupancy requirements Fair housing requirements 11.Interior requirements shall include the following: Interior finishes(flame spread/smoke development) Light and ventilation(including corresponding portion of the energy code) Sanitation 12. Special systems: Elevators Escalators Lifts 13. Swimming pools: Barrier requirements 27 Spas Wading pools 14.Location and installation details.The specific location and installation details of each fire door, fire damper, ceiling damper and smoke damper shall be shown and properly identified on the building plans by the designer. Electrical 1. Electrical: Wiring Services Feeders and branch circuits Overcurrent protection Grounding Wiring methods and materials GFCIs Electrical portions of the Energy Code(including calculation and mandatory requirements) 2. Equipment 3. Special occupancies 4. Emergency systems 5. Communication systems 6. Low voltage 7. Load calculations 8. Design flood elevation Plumbing 1. Minimum plumbing facilities 2. Fixture requirements 3. Water supply piping 4. Sanitary drainage 5. Water heaters 6. Vents 7. Roof drainage 8. Back flow prevention 9. Irrigation 10. Location of water supply line 11.Grease traps 12. Environmental requirements 13. Plumbing riser 14. Design flood elevation 15. Water/plumbing portions of the Energy Code(including calculation and mandatory requirements) Mechanical 1. Mechanical portions of the energy calculations 2. Exhaust systems: Clothes dryer exhaust Kitchen equipment exhaust Specialty exhaust systems 3. Equipment 4. Equipment location 28 5. Make-up air 6. Roof-mounted equipment 7. Duct systems 8. Ventilation 9. Combustion air 10. Chimneys,fireplaces and vents 11.Appliances 12.Boilers 13.Refrigeration 14. Bathroom ventilation 15. Laboratory 16. Design flood elevation 17. Smoke and/or Fire Dampers Gas 1. Gas piping 2. Venting 3. Combustion air 4. Chimneys and vents 5. Appliances 6. Type of gas 7. Fireplaces 8. LP tank location 9. Riser diagram/shutoffs 10. Design flood elevation 11.Gas portions of the Energy Code(including calculation and mandatory requirements) Demolition 1. Asbestos removal Residential(one-and two-family): 1. Site requirements: Setback/separation(assumed property lines) Drainage Plan(professionally prepared) Set back/separation(assumed property lines) Location of septic tanks 2. Fire-resistant construction(if required) 3. Fire 4. Smoke detector locations 5. Egress Egress window size and location stairs construction requirements 6. Structural requirements shall include: Wall section from foundation through roof,including assembly and materials,connector tables, wind requirements,and structural calculations(if required) Termite protection Design loads Wind requirements Building envelope Foundation Wall systems 29 Floor systems Roof systems Flood hazard areas,flood zones,design flood elevations, lowest floor elevations,enclosures, equipment,and flood damage-resistant materials 7.Accessibility requirements: show/identify accessible bath 8. Impact resistant coverings or systems 9.Residential Energy Code submittal(including calculation and mandatory requirements) 10.Electrical: Electric service riser with wire sizes,conduit detail and grounding detail Complete load calculations,Panel schedules 11.Mechanical: Equipment and location,Duct systems 12.Plumbing: Plumbing riser 13.Gas: Gas piping Venting Combustion air Chimneys and vents Appliances Type of gas Fireplaces LP tank location Riser diagram/shutoffs 14. Swimming Pools Barrier requirements Spas Wading pools Manufactured buildings/housing— 1. Site requirements Setback/separation(assumed property lines) Location of septic tanks(if applicable) 2. Structural Wind zone Anchoring Blocking 3. Plumbing List potable water source and meter size(if applicable) 4. Mechanical Exhaust systems Clothes dryer exhaust Kitchen equipment exhaust 5. Electrical exterior disconnect location Exemptions. Plans examination by the Building Official shall not be required for the following work: 30 1. Replacing existing equipment such as mechanical units,water heaters,etc. 2. Reroofs(as determined by local jurisdiction) 3. Minor electrical,plumbing and mechanical repairs 4. Annual maintenance permits 5. Prototype plans Except for local site adaptions, siding,foundations and/or modifications. Except for structures that require waiver. 6. Manufactured buildings plan except for foundations and modifications of buildings on site and as listed above in manufactured buildings/housing. 107.4 Amended construction documents. Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in compliance with the approved construction documents shall be resubmitted for approval as an amended set of construction documents. 107.5 Retention of construction documents.One set of approved construction documents shall be retained by the Building Official for a period of not less than 180 days from date of completion of the permitted work,or as required by state or local laws. 107.6 Affidavits.The Building Official may accept a sworn affidavit from a registered architect or engineer stating that the plans submitted conform to the technical codes. For buildings and structures,the affidavit shall state that the plans conform to the laws as to egress,type of construction and general arrangement and, if accompanied by drawings, show the structural design and that the plans and design conform to the requirements of the technical codes as to strength,stresses,strains,loads and stability.The Building Official may without any examination or inspection accept such affidavit, provided the architect or engineer who made such affidavit agrees to submit to the Building Official copies of inspection reports as inspections are performed and upon completion of the structure, electrical, gas, mechanical or plumbing systems a certification that the structure, electrical, gas, mechanical or plumbing system has been erected in accordance with the requirements of the technical codes. Where the Building Official relies upon such affidavit,the architect or engineer shall assume full responsibility for compliance with all provisions of the technical codes and other pertinent laws or ordinances. The Building Official shall ensure that any person conducting plans review is qualified as a plans examiner under Part XII of Chapter 468, Florida Statutes, and that any person conducting inspections is qualified as a building inspector under Part XII of Chapter 468,Florida Statutes.Nothing aforesaid shall preclude plan review or inspections by the Building Official (See also Section 105.14).On applications in which private provider services are utilized,all time frames shall adhere to time frames as indicated in Florida Statutes 553.791 (7). 107.6.1 Building permits issued in special flood hazard areas on the basis of an affidavit. Pursuant to the requirements of federal regulation for participation in the National Flood Insurance Program (44 C.F.R. Parts 59 and 60), the authority granted to the Building Official to issue permits, to rely on inspections, and to accept plans and construction documents on the basis of affidavits and plans submitted pursuant to Sections 105.14 and 107.6,shall not extend to the flood load and flood resistance construction requirements of the Florida Building Code. 107.6.2 Affidavits Provided Pursuant to Section 553.791, Florida Statutes. For a building or structure in a flood hazard area,the Building Official shall review any affidavit certifying compliance with the flood load and flood-resistant construction requirements of the Florida Building Code. SECTION 108 TEMPORARY STRUCTURES AND USES 31 108.1 General.The Building Official is authorized to issue a permit for temporary structures and temporary uses. Such permits shall be limited as to time of service,but shall not be permitted for more than 180 days. The Building Official is authorized to grant extensions for demonstrated cause. 108.2 Conformance. Temporary structures and uses shall comply with the requirements in Section 3103 of the Florida Building Code. 108.3 Temporary power.The Building Official is authorized to give permission to temporarily supply and use power in part of an electric installation before such installation has been fully completed and the final certificate of completion has been issued. The part covered by the temporary certificate shall comply with the requirements specified for temporary lighting,heat or power in NFPA 70. 108.4 Termination of approval. The Building Official is authorized to terminate such permit for a temporary structure or use and to order the temporary structure to be removed or use to be discontinued. SECTION 109 FEES 109.1 Payment of fees. A permit shall not be valid until the fees prescribed by law have been paid, nor shall an amendment to a permit be released until the additional fee,if any,has been paid. 109.2 Schedule of permit fees.On buildings,structures,electrical,gas,mechanical,and plumbing systems or alterations requiring a permit, a fee for each permit shall be paid as required, in accordance with the schedule as established by the Village of Tequesta Village Council. 109.2.1 Types of Fees Enumerated. Fees may be charged for but not limited to the following: • Permits; • Plans examination' • Certificates of competency(including fees for applications, examinations, renewal, late renewal,and reciprocity); • Re-inspections; • Administrative fees(including fees for investigative and legal costs incurred in the context of certain disciplinary cases heard by the board); • Variance requests; • Administrative appeals; • Violations;and • Other fees as established by local resolution or ordinance 109.3 Building permit valuations. The applicant for a permit shall provide an estimated permit value at time of application. Permit valuations shall include total value of work, including materials and labor, for which the permit is being issued, such as electrical, gas, mechanical, plumbing equipment and permanent systems. If, in the opinion of the Building Official,the valuation is underestimated on the application,the permit shall be denied,unless the applicant can show detailed estimates to meet the approval of the Building Official.Final building permit valuation shall be set by the Building Official. 109.4 Work commencing before permit issuance. Any person who commences any work on a building, structure,electrical,gas,mechanical or plumbing system before obtaining the necessary permits or without prior approval from the Building Official as permitted in Section 105.2.2 or 105.12 shall be subject to a fee established by the Building Official that shall be in addition to the required permit fees established and 32 adopted by the Village of Tequesta Village Council. This provision shall not apply to emergency work when delay would clearly have placed life or property in imminent danger. But in all such cases the required permit(s)must be applied for within three(3)business days and any unreasonable delay in obtainingthose permit(s) shall result in the charge of a triple fee. The payment of a triple fee shall not preclude or be deemed a substitute for prosecution for commencing work without first obtaining a permit. The Building Official may grant extensions of time or waive fees when justifiable cause has been demonstrated in writing. 109.5 Related fees.The payment of the fee for the construction,alteration,removal or demolition for work done in connection to or concurrently with the work authorized by a building permit shall not relieve the applicant or holder of the permit from the payment of other fees that are prescribed by law. 109.6 Refunds. The Building Official is authorized to establish and publish a refund policy through local ordinance or resolution. SECTION 110 INSPECTIONS 110.1 General. Construction or work for which a permit is required shall be subject to inspection by the Building Official and such construction or work shall remain exposed and provided with access for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of this code or of other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of this code or of other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain exposed and provided with access for inspection purposes. The Building Official shall be permitted to require a boundary line survey prepared by a qualified surveyor whenever the boundary lines cannot be readily determined in the field. Neither the Building Official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. 110.1.1 Manufacturers and fabricators.When deemed necessary by the Building Official,he/she shall make,or cause to be made,an inspection of materials or assemblies at the point of manufacture or fabrication. A record shall be made of every such examination and inspection and of all violations of the technical codes. 110.11 Inspection service. The Building Official may make, or cause to be made,the inspections required by Section 110. He or she may accept reports of department inspectors, independent inspectors or of recognized inspection services,provided that after investigation he/she is satisfied as to their licensure, qualifications and reliability. A certificate required by any provision of this code shall not be based on such reports unless the same are recorded by the building code inspector or the architect or engineer performing building code inspections in a manner specified by the Building Official. The Building Official shall ensure that all persons making such inspections shall be certified in accordance to Chapter 468 Florida Statues; or licensed under Chapter 471 or 481 Florida Statutes. The Building Official may require the owner to employ an inspection service in the following instances: 1. For buildings or additions of Type I construction; 2. For all maior structural alterations; 3. Where the concrete design is based on compressive strength in excess of 3000 pounds per square inch; 33 4. For pile driving; 5.For buildings with an area greater than 20,000 square feet; 6.For buildings more than two stories in height;or 7. For buildings and structures of unusual design or methods of construction. Such inspectors shall be present when work is underway on the structural elements of the building to adequately attest to its compliance. Such inspectors shall be registered architect, or engineer. An employee of the architect or engineer licensed under Chapter 468,Part XII, Florida Statutes may perform the inspections,under the direction of and with final certification from the architect or engineer. Such inspectors shall submit weekly progress reports including the daily inspections to the building official, and including a code compliance opinion of the resident inspector. At the completion of the construction work or project,the architect or engineer shall submit a certificate of compliance to the Building Official,stating that the work was done in compliance with this code and in accordance with the permitted drawing. Final inspection shall be made by the Building Official before a Certificate of Occupancy or Certificate of Completion is issued;and confirmation inspections may be made at any time to monitor activities and resident inspectors. 110.13 Affidavit for inspection. With specific prior approval of, and in a format acceptable to the Building Official,an affidavit for certification of inspection may be accepted from the permit qualifier; when accompanied by extensive photographic evidence of sufficient detail to demonstrate code compliance.The photographic evidence shall be comprehensive in the display of the installation and/or construction and job location identifiers.The affidavit and accompanying photographs shall be provided to the inspector onsite,at the next scheduled inspection. If the photographs are found to be insufficient by the Building Official to demonstrate compliance with this code and/or the permitted document, or clearly display location identifiers,or are missing,the inspector shall require the contractor to obtain the services of a registered Florida professional engineer to inspect and certify the installation and/or construction. 110.1.3.1 Exception: Affidavits may not be accepted for inspection of elements of construction which require inspection by the Village of Tequesta under the requirements of Title 44, Code of Federal Regulations,Parts 59 and 60,and the local flood damage prevention ordinance. 110.2 Preliminary inspection. Before issuing a permit,the Building Official is authorized to examine or cause to be examined buildings,structures and sites for which an application has been filed. 1103 Required inspections. The Building Official upon notification from the permit holder or his or her agent shall make the following inspections, or any other such inspection as deemed necessary and shall either release that portion of the construction or shall notify the permit holder or his or her agent of any violations which must be corrected in order to comply with the technical codes.The Building Official shall determine the timing and sequencing of when inspections occur and what elements are inspected at each inspection. Building 1. Foundation inspection.To be made after trenches are excavated,any required reinforcing steel is in place,forms erected and shall at a minimum include the following building components: •Stem-wall -Monolithic slab-on-grade 34 Piling/pile caps -Footers/grade beams 1.1. Slab Inspection: Concrete slab and under-floor inspections shall be made after in-slab or under-floor reinforcing steel and building service equipment, conduit, piping accessories and other ancillary equipment items are in place,but before any concrete is placed or floor sheathing installed,including the subfloor. 1.2A foundation/Form board survey prepared and certified by a registered surveyor may be required, prior to approval of the slab inspection. The survey shall certify placement of the building on the site,illustrate all surrounding setback dimensions and shall be available at the job site for review by the building inspector. In lieu of providing a survey, the contractor may elect to uncover all property line markers and string-up all property lines in preparation for inspection. 1.3. In flood hazard areas, upon placement of the lowest floor, including basement, and prior to further vertical construction,the elevation certification shall be submitted to the Authority having Jurisdiction. 2. Framing inspection.To be made after the roof,all framing, fire blocking and bracing is in place, all concealing wiring,all pipes,chimneys,ducts and vents are complete and the rough electrical, plumbing, heating wires, pipes and ducts are approved and shall at a minimum include the following building components: •Window/door framing -Window U-factor/SHGC as indicated on approved energy calculations •Vertical cells/columns •Lintel/tie beams -Framing/trusses/bracing/connectors(including truss layout and engineered drawings) •Draft stopping/fire blocking •Curtain wall framing •Energy insulation(Insulation R-factor as indicated on approved energy calculations) •Accessibility. •Verify rough opening dimensions are within tolerances. -Window/door buck attachment 2.1. Insulation Inspection: To be made after the framing inspection is approved and the insulation is in place, according to approved energy calculation submittal Includes wall and ceiling insulation. 35 2.2.Lath and gypsum board inspection for fire-resistance-rated or shear assemblies.Lath and gypsum board inspections shall be made after lathing and gypsum board,interior and exterior,is in place, but before any plastering is applied or gypsum board joints and fasteners are taped and finished. 3. Sheathing inspection. To be made either as part of a dry-in inspection or done separately at the request of the contractor after all roof and wall sheathing and fasteners are complete and shall at a minimum include the following building components: -Roof sheathing •Wall sheathing -Continuous air barrier -Exterior Siding/Cladding •Sheathing fasteners -Roof/wall dry-in. NOTE: Sheathing fasteners installed and found to be missing the structural member(shiners)shall be removed and properly reinstalled prior to installation of the dry-in material. Exception: ring shank nails shall be bent over and a new fastener installed. 4.Exterior wall coverings.Shall at a minimum include the following building components in progress inspections: • Exterior wall coverings and veneers • Soffit coverings 5. Roofing inspection. Shall at a minimum be made in at least two inspections and include the following building components: •Dry-in -Insulation •Roof coverings(including In Progress as necessary) -Insulation on roof deck(according to submitted energy calculation) Flashing -Sheathing 5.1. Re-Roof sheathing inspection. An affidavit with a notarized signature of a state or locally licensed roofing contractor for the installation of additional sheathing fasteners as required by the Existing Building Code may be accepted at the discretion of the Building Official. 36 6. Final inspection.To be made after the building, including all sub-trade inspections, is completed and ready for occupancy. 6.1. In flood hazard areas, as part of the final inspection, a final certification of the lowest floor elevation or the elevation to which a building is dry floodproofed, as applicable, shall be submitted to the authority having jurisdiction. 7. Swimming pool inspection.First inspection to be made after excavation and installation of reinforcing steel,bonding and main drain and prior to placing of concrete shell. 1. Steel reinforcement inspection 2. Underground electric inspection. 3. Underground piping inspection including a pressure test. 4. Underground electric inspection under deck area(including the equipotential bonding) 5. Underground piping inspection under deckarea.. 6. Deck inspection:to be made prior to installation of the deck material (with forms,deck drains,and any reinforcement in place 7. Safety Inspection;Made prior to filling the pool with the bonding connections made,the proper drain covers installed and the final barriers installed. 8. Final pool piping. 9. Final Electrical inspection. 10. Final inspection to be made when the swimming pool is complete and all required enclosure requirements are in place. In order to pass final inspection and receive a certificate of completion,a residential swimming pool must meet the requirements relating to pool safety features as described in Section 454.2.17and R4501.17 of this code. 8. Demolition inspections. First inspection to be made after all utility connections have been disconnected and secured in such manner that no unsafe or unsanitary conditions shall exist during or after demolition operations. Final inspection to be made after all demolition work is completed. 9. Manufactured building inspections.The Department of Building Safety shall inspect construction of foundations; connecting buildings to foundations; installation of parts identified on plans as site installed items,joining the modules,including utility crossovers;utility connections from the building to utility lines on site; and any other work done on site which requires compliance with the Florida Building Code. Additional inspections may be required for public educational facilities(see Section 453.27.20 of this code). 10. Where impact resistant coverings or impact resistant systems are installed,the Building Official shall schedule adequate inspections of impact resistant coverings or impact resistant systems to determine the following: The system indicated on the plans was installed. The system is installed in accordance with the manufacturer's installation instructions and the product approval. 37 Electrical 1. Underground inspection. To be made after trenches or ditches are excavated,conduit or cable installed,and before any backfill is put in place. 2. Rough-in inspection.To be made after the roof,framing,fireblocking and bracing is in place and prior to the installation of wall or ceiling membranes. 3. Final inspection.To be made after the building electrical system is complete,all required electrical fixtures are in place and properly connected or protected,and the structure is ready foroccupancy. 4. Existing Swimming Pools. To be made after all repairs or alterations are complete, all required electrical equipment, GFCI protection, and equipotential bonding are in place on said alterations or repairs. Plumbing 1. Underground inspection.To be made after trenches or ditches are excavated,piping installed,and before any backfill is put in place. 2. Rough-in inspection.To be made after the roof,framing,fireblocking and bracing is in place and all soil,waste and vent piping is complete,and prior to this installation of wall or ceiling membranes. -includes plumbing provisions of the energy code and approved energy calculations provisions. 3. Final inspection.To be made after the building plumbing system is complete,all plumbing fixtures are in place and properly connected,and the structure is ready for occupancy. Note: See Section 312 of the Florida Building Code,Plumbing for required tests. Mechanical 1. Underground inspection. To be made after trenches or ditches are excavated, underground duct and fuel piping installed,and before any backfill is put in place. 2. Rough-in inspection. To be made after the roof, framing, fire blocking and bracing are in place and all ducting, and other concealed components are complete, and prior to the installation of wall or ceiling membranes. -includes mechanical provisions of the energy code and approved energy calculations provisions. 3. Final inspection.To be made after the building mechanical system is complete,the mechanical system is in place and properly connected,and the structure is ready for occupancy. 38 Gas 1. Rough piping inspection. To be made after all new piping authorized by the permit has been installed, and before any such piping has been covered or concealed or any fixtures or gas appliances have been connected. -includes gas provisions of the energy code and approved energy calculations provisions. 2. Final piping inspection. To be made after all piping authorized by the permit has been installed and after all portions which are to be concealed by plastering or otherwise have been so concealed, and before any fixtures or gas appliances have been connected.This inspection shall include a pressure test. 3. Final inspection. To be made on all new gas work authorized by the permit and such portions of existing systems as may be affected by new work or any changes,to ensure compliance with all the requirements of this code and to assure that the installation and construction of the gas system is in accordance with reviewed plans. Site Debris 1.The contractor and/or owner of any active or inactive construction project shall be responsible for the clean-up and removal of all construction debris or any other miscellaneous discarded articles during the course of the construction project and prior to receiving final inspection approval. Construction job sites must be kept clean and in a safe condition at all times. 2.All debris shall be kept in such a manner as to prevent it from being spread by any means. 1103.1 Footing and foundation inspection. Footing and foundation inspections shall be made after excavations for footings are complete and any required reinforcing steel is in place. For concrete foundations, any required forms shall be in place prior to inspection. Materials for the foundation shall be on the job,except where concrete is ready mixed in accordance with ASTM C 94,the concrete need not be on the job. 11031 Concrete slab and under-floor inspection. Concrete slab and under-floor inspections shall be made after in-slab or under-floor reinforcing steel and building service equipment, conduit, piping accessories and other ancillary equipment items are in place, but before any concrete is placed or floor sheathing installed,including the subfloor. 11033 Lowest floor elevation. In flood hazard areas,upon placement of the lowest floor,including the basement,and prior to further vertical construction,the elevation certification required in Section 1612.4 of the Florida Building Code, Building and Section R322 of the Florida Building Code, Residential, shall be submitted to the Building Official. 1103.4 Frame inspection. Framing inspections shall be made after the roof deck or sheathing, all framing, fire blocking and bracing are in place and pipes, chimneys and vents to be concealed are complete and the rough electrical,plumbing,heating wires,pipes and ducts are approved. 110M Lath,gypsum board and gypsum panel product inspection.Lath,gypsum board and gypsum panel product inspections shall be made after lathing,gypsum board and gypsum panel products,interior and exterior, are in place, but before any plastering is applied or gypsum board and gypsum panel product joints and fasteners are taped and finished. 39 Exception: Gypsum board and gypsum panel products that are not part of a fire-resistance-rated assembly or a shear assembly. 1103.6 Weather-exposed balcony and walking surface waterproofing. Where balcony or other elevated walking surfaces are exposed to water from direct or blowing rain, snow or irrigation,and the structural framing is protected by an impervious moisture barrier, all elements of the impervious- moisture-barrier system shall not be concealed until inspected and approved. 1103.7 Fire-and smoke-resistant penetrations.Protection of joints and penetrations in fire-resistance rated assemblies, smoke barriers and smoke partition shall not be concealed from view until inspected and approved. 1103.8 Energy efficiency inspections. Inspections shall be made to determine compliance with FBC, Energy Conservation and confirm with the approved energy code submittal (by appropriate trade)and corresponding mandatory requirements and shall include, but not be limited to, inspections for: corresponding envelope insulation R- and U-values, fenestration U-value and Solar Heat Gain Coefficient, duct system R-value, and HVAC, lighting, electrical and water-heating equipment efficiency. 1103.9 Other inspections. In addition to the inspections specified in Sections 110.3 through 110.3.7, the Building Official is authorized to make or require other inspections of any construction work to ascertain compliance with the provisions of this code and other laws that are enforced by the department of building safety. 1103.10 Special inspections. Reserved. 1103.11 Final inspection.The final inspection shall be made after all work required by the building permit is completed. 1103.11.1 Flood hazard documentation.If located in a flood hazard area,coastal high hazard areas or coastal A zones, documentation as required in Section 1612.5 of the Florida Building Code, Building; or Section R322 of the Florida Building Code, Residential, shall be submitted to the Building Official prior to the final inspection. 110.3.11.2 Commercial Energy Code documentation.If required by energy code path submittal, confirmation that commissioning result requirements have been received by building owner. 110.3.11.3 Residential Energy Code documentation. If required by energy code path submittal (Section R405),confirmation that the envelope and duct test requirements shall be received by Building Official. 1103.12 Termites. Building components and building surroundings required to be protected from termite damage in accordance with Section 1503.7, Section 2304.13 or Section 2304.11.6, specifically required to be inspected for termites in accordance with Section 2114,or required to have chemical soil treatment in accordance with Section 1816 shall not be covered or concealed until the release from the Building Official has been received. 40 1103.13 Impact resistant coverings or systems. Where impact resistant coverings or systems are installed to meet requirements of this code,the Building Official shall schedule adequate inspections of impact resistant coverings or systems to determine the following: 1.The system indicated on the plans was installed. 2. The system is installed in accordance with the manufacturer's installation instructions and the product approval. 110.4 Inspection agencies. The Building Official is authorized to accept reports of approved inspection agencies,provided such agencies satisfy the requirements as to qualifications and reliability. 1105 Inspection requests. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the Building Official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. 110.6 Approval required.Work shall not be done beyond the point indicated in each successive inspection without first obtaining the approval of the Building Official.The Building Official,upon notification,shall make the requested inspections and shall either indicate the portion of the construction that is satisfactory as completed, or notify the permit holder or his or her agent wherein the same fails to comply with this code.Any portions that do not comply shall be corrected and such portion shall not be covered or concealed until authorized by the Building Official. 110.7 Shoring. For threshold buildings, shoring and associated formwork or falsework shall be designed and inspected by a Florida licensed professional engineer, prior to any required mandatory inspections by the threshold building inspector. 110.8 Threshold building. 110.8.1 During new construction or during repair or restoration projects in which the structural system or structural loading of a building is being modified,the enforcing agency shall require a special inspector to perform structural inspections on a threshold building pursuant to a structural inspection plan prepared by the engineer or architect of record. The structural inspection plan must be submitted to the enforcing agency prior to the issuance of a building permit for the construction of a threshold building. The purpose of the structural inspection plans is to provide specific inspection procedures and schedules so that the building can be adequately inspected for compliance with the permitted documents. The special inspector may not serve as a surrogate in carrying out the responsibilities of the Building Official, the architect, or the engineer of record. The contractor's contractual or statutory obligations are not relieved by any action of the special inspector. 110.8.2 The special inspector shall determine that a professional engineer who specializes in shoring design has inspected the shoring and reshoring for conformance with the shoring and reshoring plans submitted to the enforcing agency. A fee simple title owner of a building, which does not meet the minimum size,height, occupancy, occupancy classification, or number-of-stories criteria which would result in classification as a threshold building under Section 553.71(7),Florida Statutes,may designate such building as a threshold building,subject to more than the minimum number of inspections required by the Florida Building Code. 110A3 The fee owner of a threshold building shall select and pay all costs of employing a special inspector, but the special inspector shall be responsible to the enforcement agency.The inspector shall be a person certified,licensed or registered under Chapter 471,Florida Statutes,as an engineer or under Chapter 481,Florida Statutes,as an architect. 41 110.8.4 The Village of Tequesta shall require that,on every threshold building: 110.8.4.1 The special inspector, upon completion of the building and prior to the issuance of a certificate of occupancy, file a signed and sealed statement with the enforcement agency in substantially the following form: "To the best of my knowledge and belief, the above described construction of all structural load-bearing components complies with the permitted documents, and the shoring and reshoring conforms to the shoring and reshoring plans submitted to the enforcement agency." 110.8.4.2 Any proposal to install an alternate structural product or system to which building codes apply be submitted to the enforcement agency for review for compliance with the codes and made part of the enforcement agency's recorded set of permit documents. 110.8.43 All shoring and reshoring procedures, plans and details be submitted to the enforcement agency for recordkeeping.Each shoring and reshoring installation shall be supervised,inspected and certified to be in compliance with the shoring documents by the contractor. 110.8.4.4 All plans for the building which are required to be signed and sealed by the architect or engineer of record contain a statement that, to the best of the architect's or engineer's knowledge, the plans and specifications comply with the applicable minimum building codes and the applicable fire-safety standards as determined by the local authority in accordance with this Section and Chapter 633,Florida Statutes. HOW The Village of Tequesta shall not issue a building permit for construction of any threshold building except to a licensed general contractor, as defined in Section 489.105(3)(a), Florida Statutes, or to a licensed building contractor, as defined in Section 489.105(3)(b), Florida Statutes, within the scope of her or his license. The named contractor to whom the building permit is issued shall have the responsibility for supervision, direction, management and control of the construction activities on the project for which the building permit was issued. 110.8.E The Department of Building Safety may allow a special inspector to conduct the minimum structural inspection of threshold buildings required by this code, Section 553.73, Florida Statutes, without duplicative inspection by the Department of Building Safety. The Building Official is responsible for ensuring that any person conducting inspections is qualified as a building inspector under Part XII of Chapter 468, Florida Statutes, or certified as a special inspector under Chapter 471 or 481, Florida Statutes. Inspections of threshold buildings required by Section 553.79(5),Florida Statutes, are in addition to the minimum inspections required by this code. 110.9 Impact of construction. All construction activity regulated by this code shall be performed in a manner so as not to adversely impact the condition of adjacent property, unless such activity is permitted to affect said property pursuant to a consent granted by the applicable property owner, under terms or conditions agreeable to the applicable property owner. This includes, but is not limited to, the control of dust, noise, water or drainage runoffs, debris, and the storage of construction materials. New construction activity shall not adversely impact legal historic surface water drainage flows serving adjacent properties, and may require special drainage design complying with engineering standards to preserve the positive drainage patterns of the affected sites. Accordingly, developers, contractors and owners of all new residential development, including additions, pools, patios, driveways, decks or similar items, on existing properties resulting in a significant decrease of permeable land area on any parcel or has altered the drainage flow on the developed property shall,as a permit condition,provide a professionally prepared drainage plan clearly indicating compliance with this paragraph. Upon completion of the improvement, a certification 42 from a licensed professional,as appropriate under Florida law,shall be submitted to the inspector in order to receive approval of the final inspection. SECTION 111 CERTIFICATE OF OCCUPANCY 111.1 Use and occupancy.A building or structure shall not be used or occupied,and a change in the existing use or occupancy classification of a building or structure or portion thereof shall not be made, until the Building Official has issued a certificate of occupancy therefore as provided herein.Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of this code or of other ordinances of the jurisdiction. Exception: Certificates of occupancy are not required for work exempt from permits under Section 105.2. 1111 Certificate issued. After the Building Official inspects the building or structure and finds no violations of the provisions of this code or other laws that are enforced by the department of building safety, the Building Official shall issue a certificate of occupancy that contains the following: 1.The building permit number. 2.The address of the structure. 3.The name and address of the owner or the owner's authorized agent. 4.A description of that portion of the structure for which the certificate is issued. 5.A statement that the described portion of the structure has been inspected for compliance with the requirements of this code for the occupancy and division of occupancy and the use for which the proposed occupancy is classified. 6. For buildings and structures in flood hazard areas, a statement that documentation of the as-built lowest floor elevation has been provided and is retained in the records of the authority having jurisdiction. 7.The name of the Building Official. 8.The edition of the code under which the permit was issued. 9.The use and occupancy,in accordance with the provisions of Chapter 3. 10.The type of construction as defined in Chapter 6. 11.The design occupant load. 12. If an automatic sprinkler system is provided,whether the sprinkler system is required. 13.Any special stipulations and conditions of the building permit. 43 1113 Temporary occupancy. The Building Official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely.The Building Official shall set a time period during which the temporary certificate of occupancy is valid. 111A Revocation. The Building Official is authorized to, in writing, suspend or revoke a certificate of occupancy or completion issued under the provisions of this code wherever the certificate is issued in error, or on the basis of incorrect information supplied, or where it is determined that the building or structure or portion thereof is in violation of any ordinance or regulation or any of the provisions of this code. 1115 Certificate of Completion. A Certificate of Completion is proof that a structure or system is complete and for certain types of permits is released for use and may be connected to a utility system.This certificate does not grant authority to occupy a building, such as shell building, prior to the issuance of a Certificate of Occupancy. SECTION 112 SERVICE UTILITIES 112.1 Connection of service utilities. No person shall make connections from a utility, source of energy, fuel or power to any building or system that is regulated by this code for which a permit is required, until released by the Building Official. 1121 Temporary connection. The Building Official shall have the authority to authorize the temporary connection of the building or system to the utility source of energy,fuel or power. 1123 Authority to disconnect service utilities.The Building Official shall have the authority to authorize disconnection of utility service to the building,structure or system regulated by this code and the referenced codes and standards set forth in Section 101.4 in case of emergency where necessary to eliminate an immediate hazard to life or property or when such utility connection has been made without the approval required by Section 112.1 or 112.2. The Building Official shall notify the serving utility, and wherever possible the owner and occupant of the building, structure or service system of the decision to disconnect prior to taking such action. If not notified prior to disconnecting, the owner or occupant of the building, structure or service system shall be notified in writing,as soon as practical thereafter. SECTION 113 BOARD OF APPEALS RESERVED SECTION 114 VIOLATIONS 114.1 Unlawful acts. It shall be unlawful for any person, firm or corporation to erect, construct, alter, extend,repair,move,remove,demolish or occupy any building, structure or equipment regulated by this code,or cause same to be done, in conflict with or in violation of any of the provisions of this code. 1141 Notice of violation.The Building Official is authorized to serve a notice of violation or order on the person responsible for the erection,construction,alteration,extension,repair,moving,removal,demolition or occupancy of a building or structure in violation of the provisions of this code,or in violation of a permit or certificate issued under the provisions of this code. Such order shall direct the discontinuance of the illegal action or condition and the abatement of the violation. 44 1143 Prosecution of violation. If the notice of violation is not complied with promptly, the Building Official is authorized to request the legal counsel of the jurisdiction to institute the appropriate proceeding at law or in equity to restrain, correct or abate such violation, or to require the removal or termination of the unlawful occupancy of the building or structure in violation of the provisions of this code or of the order or direction made pursuant thereto. 114.4 Violation penalties.Any person who violates a provision of this code or fails to comply with any of the requirements thereof or who erects, constructs, alters or repairs a building or structure in violation of the approved construction documents or directive of the Building Official,or of a permit or certificate issued under the provisions of this code,shall be subject to penalties as prescribed by law. SECTION 115 STOP WORK ORDER 115.1 Authority. Whenever the Building Official finds any work regulated by this code being performed in a manner either contrary to the provisions of this code or dangerous or unsafe,the Building Official is authorized to issue a stop work order. 115.2 Issuance. The stop work order shall be in writing and shall be given to the owner of the property involved, the owner's authorized agent or the person performing the work. Upon issuance of a stop work order,the cited work shall immediately cease. The stop work order shall state the reason for the order and the conditions under which the cited work will be permitted to resume. 1153 Unlawful continuance. Any person who shall continue any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be subject to penalties as prescribed by law. SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT 116.1 Unsafe buildings or systems. All buildings, structures, electrical, gas, mechanical or plumbing systems which are unsafe,unsanitary, or do not provide adequate egress,or which constitute a fire hazard, or are otherwise dangerous to human life,or which in relation to existing use,constitute a hazard to safety or health, are considered unsafe buildings or service systems. All such unsafe buildings, structures or service systems are hereby declared illegal and shall be ordered by the Building Official to be abated by the owner, through repair and rehabilitation or by demolition in accordance with this Code. The extent or repairs shall be determined by the Building Official. 116.1.1 When the Building Official determines a building, structure, electrical, gas, mechanical or plumbing system or portion thereof is unsafe,as set forth in this Code he/she shall provide the owner, agent or person in control of such building,structure,electrical,gas,mechanical or plumbing system a written notice of violation stating the defects thereof. This notice shall require the owner within a stated time either to complete specified repairs or improvements, or to demolish and remove the building, structure,electrical,gas,mechanical or plumbing system or portion thereof. At the option of the Village of Tequesta, the processes and procedures for code enforcement under Chapter 162, Florida Statutes, or Article V, Sec. 14-121, and Appendix B of the Village of Tequesta Code of Ordinances may be utilized to abate a violation under this section. If the statutory method of enforcement is invoked, the Building Official shall act in the role of code inspector as authored in Section 114 of this code to initiate enforcement proceedings,and notice shall be in accordance with the provisions of the Statute. 45 116.1.2 If necessary, the notice shall also require the building, structure, electrical, gas, mechanical, plumbing systems or portion thereof to be vacated and/or disconnected, and not reoccupied and/or reconnected until the specified repairs and improvements are completed, inspected and approved by the Building Official. The Building Official shall post at each entrance to the building a placard stating: THIS BUILDING IS UNSAFE AND ITS USE OR OCCUPANCY HAS BEEN PROHIBITED BY THE BUILDING OFFICIAL. This placard shall remain posted until the required repairs are made or demolition is completed. It shall be unlawful for any person,firm or corporation or its officers,agents, or other servants,to remove the posting without written permission of the Building Official,or for any person to enter the building, or use the building or system(s) except for the purpose of making the required repairs or of demolishing same. 116.13 In case the owner, agent, or person in control cannot be found within the stated time limit, or, if such owner, agent, or person in control shall fail, neglect, or refuse to comply with notice to repair, rehabilitation or to demolish, and remove said building, structure, electrical, gas, mechanical or plumbing system or portion thereof, the Building Official, acting as a code inspector, shall notify an enforcement board and request a hearing. In the case of the violation posing a serious threat, and after having ascertained the cost, the Building Official may take action to cause such building, structure, electrical,gas, mechanical or plumbing system or portion thereof, to be demolished,secured,repaired, or required to remain vacant or unused. Taking such action does not create a continuing obligation on the part of the Building Official to continue with maintaining such building, structure or system, or create liability for any damage to the property. 116.1.4 The decision of the Building Official shall be final in cases of emergency,which,in the opinion of the Building Official, involve imminent danger to human life or health, or the property of others. He/she shall promptly cause such building, structure, electrical, gas, mechanical or plumbing system or portion thereof to be made safe or cause its removal. For this purpose,he/she may at once enter such structure or land on which it stands, or abutting land or structures, which such assistance and at such cost as he may deem necessary. He/she may order the vacating of adjacent structures and may require the protection of the public by appropriate fence or such other means as may be necessary,and for this purpose may close a public or private way. 116.2 Conditions. Structures or existing equipment that are or hereafter become unsafe, insanitary or deficient because of inadequate means of egress facilities, inadequate light and ventilation, or which constitute a fire hazard,or are otherwise dangerous to human life or the public welfare,or that involve illegal or improper occupancy or inadequate maintenance, shall be deemed an unsafe condition. Unsafe structures shall be taken down and removed or made safe,as the Building Official deems necessary andas provided for in this section.A vacant structure that is not secured against entry shall be deemed unsafe. 116.3 Record.The Building Official shall cause a report to be filed on an unsafe condition.The report shall state the occupancy of the structure and the nature of the unsafe condition. 116.4 Notice.If an unsafe condition is found,the Building Official shall serve on the owner,agent or person in control of the structure,a written notice that describes the condition deemed unsafe and specifies the required repairs or improvements to be made to abate the unsafe condition, or that requires the unsafe structure to be demolished within a stipulated time. Such notice shall require the person thus notified to declare immediately to the Building Official acceptance or rejection of the terms of the order. 116.5 Method of service. Such notice shall be deemed properly served if a copy thereof is(a)delivered to the owner personally; (b) sent by certified or registered mail addressed to the owner at the last known address with the return receipt requested; or(c) delivered in any other manner as prescribed by local law. 46 If the certified or registered letter is returned showing that the letter was not delivered,a copy thereof shall be posted in a conspicuous place in or about the structure affected by such notice. Service of such notice in the foregoing manner upon the owner's agent or upon the person responsible for the structure shall constitute service of notice upon the owner. 116.6 Restoration. Where the structure or equipment determined to be unsafe by the Building Official is restored to a safe condition, to the extent that repairs, alterations or additions are made or a change of occupancy occurs during the restoration of the structure, such repairs, alterations, additions and change of occupancy shall comply with the requirements of Section 105.2.2 and the Florida Building Code, Existing Building. 116.7 Enforcement proceedings; hearing. Violation proceedings and hearings for unsafe structures and equipment will be conducted before the Village of Tequesta special magistrate in accordance with the provisions set forth in Chapter 162, Florida Statutes. The owner of property that is subject to an enforcement proceeding before the special magistrate or court is required to make disclosures as outlined in Chapter 162, Florida Statutes, before a transfer of property, and failure to make the required disclosures creates a presumption of fraud. 116.8 Administrative fines;costs to repair;liens. All costs associated with taking a case before the special magistrate shall be recovered where the jurisdiction prevails. Whenever one of the orders of the special magistrate has not been complied with by the time set for compliance,for each day thereafter during which said violation continues past the date set for compliance,the special magistrate may impose a fine.All costs incurred as a result of actions taken pursuant to Section 114 are charged to the violator. 116.9 Appeal. An aggrieved party,including the Village of Tequesta, may appeal a final administrative order of an enforcement board or special magistrate to the circuit court. Such an appeal shall not be a hearing de novo but shall be limited to appellate review of the record created before the enforcement board. An appeal shall be filed within 30 days of the execution of the order to be appealed. SECTION 117 VARIANCES IN FLOOD HAZARD AREAS 117.1 Flood hazard areas. Pursuant to Section 553.73(5), Florida Statutes, the variance procedures adopted in the local floodplain management ordinance shall apply to requests submitted to the Building Official for variances to the provisions of Section 1612.4 of the Florida Building Code, Building or, as applicable, the provisions of R322 of the Florida Building Code, Residential. This section shall not apply to Section 3109 of the Florida Building Code, Building. 47