Loading...
HomeMy WebLinkAboutDocumentation_Regular_Tab 12H_4/10/1997 e rir Memorandum To: Village Council From: Thomas G. Bradford, Village Manager Date: March 25, 1997 Subject: Loxahatchee River Environmental Control District; Public Facilities Report Florida Statute 189 .415 requires that all special districts, including the Loxahatchee River Environmental Control District (ENCON) , provide an annual Public Facilities Report to the applicable local governments in which its special district exists . Within this Public Facilities Report, the special district is required to advise the local government of all renewal and replacement projects within the corporate limits of the local government that are contemplated to take place within the upcoming fiscal year and beyond. See Exhibit 5 on Page 13 of the attached March 1997 Public Facilities Report. It is ENCON' s current practice to provide for a numerical dollar value indicating the totality of the renewal and replacement projects that it contemplates to undertake within the totality of its service area which encompasses much of Northern Palm Beach County and Southern Martin County. However, to--\Tequesta ' s detriment, this Public Facilities Report does not include specific information as to where, what, and when something will be replaced or renewed in the central sewer service system within the Village of Tequesta. This is problematic for the Village of Tequesta in that we are unable to properly plan the infrastructure activities that are our responsibility. For example, it is necessary for the Village to know when ENCON intends to replace a sewer main or a sanitary sewer manhole to avoid conflicts with our annual Street Repaving Program. However, the current Public Facilities Report is inadequate in this regard. Accordingly, Tequesta staff has written to ENCON staff in this regard as evidenced by the attached copy of the correspondence in this regard. To this date, no response has been received from the staff at ENCON relative to Tequesta' s concern. In this regard, it is requested that the Village Council approve the attached Resolution that is directed to the Governing Board of ENCON asking them to take appropriate action to amend their Public Facilities Report in order to provide specific information to the Village of Tequesta relative to renewal and replacement activities contemplated within the Corporate Limits of the Village of Tequesta. TGB/krb Attachment cc...__1\032597-2.sam iRESOLUTION NO. 15 - 96/97 • '' A RESOLUTION OF THE VILLAGE COUNCIL OF THE VILLAGE OF TEQUESTA, PALM BEACH COUNTY, FLORIDA, URGING THE GOVERNING BOARD OF THE LOXAHATCHEE RIVER ENVIRONMENTAL CONTROL Ij • DISTRICT TO AMEND ITS CURRENT AND FUTURE PUBLIC FACILITIES REPORTS TO PROVIDE FOR SPECIFIC INFORMATION TO THE VILLAGE OF II TEQUESTA RELATIVE TO RENEWAL AND REPLACEMENT ji • ACTIVITIES IN TEQUESTA. j WHEREAS, F. S. 189 . 415 requires coordination between special L districts and local general-purpose governments by the submittal of an annual Public Facilities Report by each . independent special district to the local general-purpose j governments; and ; WHEREAS, the Loxahatchee River Environmental Control j District is an independent special district and the Village i of Tequesta is a local general-purpose -government; and WHEREAS, the Public Facilities Report is required to provide li a "description of existing public facilities and a d description of each public facility the district is ; building, improving, or expanding, or is currently proposing to build, improve, or expand within at least the next five 1 (5) years and how such public facility is proposed to be financed; and II WHEREAS, if the special district proposes to replace any facilities identified within the next ten (10) years, the II date when such facility will be replaced shall be provided to the local general-purpose government, including the .anticipated time the construction, improvement, or expansion of each facility will be completed; and WHEREAS, . the Loxahatchee River Environmental Control h District current Public Facilities Report and all such reports issued since March 1, 1991, have lacked specificity .i relative to a description of existing facilities that are being proposed for building, improvement, or expansion, the II date when such facility will be replaced and the anticipated i time the construction, improvement, or expansion of each H facility will be completed within the Corporate Limits of the Village of Tequesta, a local general-purpose government within the Loxahatchee River Environmental Control Special District boundaries; and H WHEREAS, a purpose of the Public Facilties Report is to 1. allow for the preparation or revision of local government comprehensive plans such as the Village of Tequesta's, which includes a- Capital Improvement Element; and ,' WHEREAS, without specificity relative to renewal and replacement of infrastructure within the Village of Tequesta, the Loxahatchee River Environmental Control District Public Facilities Report is of no value to the Village of 'Tequesta relative to planning and programming of its necessary capital improvements potentially impacted by v such renewal and replacement activities; and WHEREAS, the Loxahatchee River Environmental Control District is subject to the franchise authority of the . Village of Tequesta which is subject to renewal consideration from time to time. NOW, THEREFORE, BE IT RESOLVED BY THE VILLAGE COUNCIL OF THE VILLAGE OF TEQUESTA, PALM BEACH COUNTY, FLORIDA, AS FOLLOWS: 1 Section 1. The foregoing recitals are hereby ratified and confirmed. 1 Section 2 . The Governing Board of the Loxahatchee River I Environmental Control District is hereby urged to direct its 1 staff to amend its current and future State required Public . Facilties Reports so that it may provide the necessary • specificity to the Village of Tequesta relative to the . • described public facilities located within the Corporate ' Limits of the Village of Tequesta which are contemplated to j be built, improved, or expanded ten (10) years into the I! future, including the date when such facility will be I replaced in order to facilitate proper comprehensive I planning and infrastructure management within the Village of • Tequesta through proper coordination as intended through the 11 State required annual Public Facilities Report. • i Section 3. The Village Clerk is hereby directed to provide h a copy of this Resolution to the Governing Board Members of I the Loxahatchee River Environmental Control District, the I. Executive Director of the Loxahatchee River Environmental • II - Control District, and the Secretary of the State of Florida • 0 Department of Community Affairs . THE FOREGOING RESOLUTION WAS OFFERED by Councilmember , who moved its adoption. The notion was ! seconded by Councilmember , and upon being '! put to a vote, the vote was as follows : II FOR ADOPTION AGAINST ADOPTION It i . i! ! !I The Mayor thereupon declared the .Resolution duly passed and !; adopted this 10th day of April, A.D. , 1997 . M MAYOR OF TEQUESTA I 11 Elizabeth A. Schauer 11' ATTEST: i Joann Manganiello s Village Clerk wnfi(1\rae\15-97 • • Loxahatchee River District 2500 Jupiter Park Die.Jupiter. Florida 33458-8964 Telephone(561)747-5700 Fax (561)747-9929 <� = '# •, ,ry i Richard C. Dent.Executive Director '1'07 1,7 y7\ Award Winning Regional liakret%ruer Fa rl;ry Bc•s;in Van,'n.E.PA. Be.0 in STOIC.D.E.P. February 28, 1997 • Village of Tequesta Village Clerk Village of Tequesta MAR - 3 1997 P.O. Box 3273 Tequesta, FL 33469 Village Manager's Office Re: Public Facilities Report • Gentlemen: • In accordance with the requirements of Chapter 189, Florida Satutes,we are pleased to provide the 1997 edition of the Loxahatchee River Environmental Contrdl,District, Public Facitilities Report. • Copies are also being provided at this time to each of the Counties and Municipalities serviced by this agency. . Sincerely, Clinton R. Y • Deputy • or CRY/kbk • Enclosure: • Alfred"Al—De Mott George(..Gentile Joseph O.F71i. • Loring E."tin:1e"Holmes tins er T1 pson.,Ir. Itoard\lembr'r \b•mhrr (.h:,irm.m mh,i 11..1n1\I,mh,r . . PUBLIC FACILITIES REPORT \. , 24,4 -:•':',1-. \\\ 0 • 1, Vis •- j 3 j 1 `ter-*Ya : J; ti ,'f. ,4 .V ,rT 'V JAI' +... .r • . Y ,,J� 4 r • - _ a 1971 MARCH, 1997 • I. INTRODUCTION The Loxahatchee River Environmental Control District is an independent special district which was created in 1971 under Chapter 71-822, Florida Statutes. This original legislation, combined with subsequent amendments, established authorities in the water resource disciplines of wastewater, water supply and stormwater _ management. The act allows the District to meet the water resource needs of the area and to provide certain urban services in a manner which is both compatible with the natural environment and cost effective for a growing community. The boundaries for the District are shown on Exhibit#1 and were drawn based on hydrologic criteria which define the drainage basin of the Loxahatchee River. Within these environmentally designed boundaries lie four municipalities and portions of the unincorporated areas of two counties. Over the past two decades, the District has shared a professional working relationship with each of these political subdivisions; and, it is recognized that current and long range planning for all District programs must continue to be undertaken in concert with the growth management objectives of our sister governments. • It is in this spirit that the Loxahatchee River Environmental Control District is pleased to submit this Public Facilities Report. As the sole pollution control authority serving the area, the District has written this document to report on the present status and future plans for the Loxahatchee River Regional Wastewater Facilities. The following information is supplied to officially identify the District and to provide consistency with previous submittals made by this agency under the provisions of Chapter 189, Florida Statutes. • District Name: Loxahatchee River Environmental Control District District Address: 2500 Jupiter Park Drive Jupiter, Florida 33458-8964 Contact Person: Richard C. Dent, Executive Director Phone Number: (561) 747-5700 . EXHIBIT #1 • ` . . \'\\ JONATHAN DICKINSON 1 STATE PARK ‘ \ \\ I ii\ If"11E 1 ` \ I � I ` r-_7).I I I k 14 1441111,0 I i11 I I L 1 • L •\ I r _ 1 • I 14 It) 1 . • .._BTIN COU�j yc9�., vo • BEACH COUNTY \ lb \ �� A \ • I NIRP INDIANlOWN RD. U a ...0 (0%.\ \\ CJ 9. \ �� p II \ � 1� Si \, � I- f XX `1 - .DONALD ROSS RD. ‘1 1 \ . Jr 1 8000' 4000' 0 8000' SCALE -- DISTRICT BOUNDARY DISTRICT BOUNDARY . LOXAHATCHEE RIVER ENVIRONMENTAL CONTROL DISTRICT WASTEWATER COLLECTION SYSTEM ll. POPULATION, DEMAND MEASUREMENTS AND LEVEL OF SERVICE In the wastewater business, the predominant demand measurement is the population for which service is provided or to be provided. Often, the population figures are converted to an engineering 'common denominator' such as an equivalent residential connection or E.R.C. A third factor employed in the water and wastewater business is flowage volumes which can be expressed in gallons per capita per day (gcd), gallons per equivalent residential connection per day (gecd) or in millions of gallons per day (MGD) of total flow from the community. For the purpose of this report and in an attempt to avoid confusion and provide consistency with the comprehensive plans developed by the multi-jurisdictional governments in the area, the demand expressions used will be limited to population, gallons per capita per day and millions of gallons. Demographic analyses for the initial planning in the 1970's were provided through the best available engineering and census data. In the 1980's,.two additional sources became available and have greatly enhanced the ability to project populations and the resultant wastewater service demand. The first source came from within the District itself. From 1978 to 1987, the Loxahatchee River Environmental Control District was recognized as an authority on growth and related demographic information., Working closely with other utilities, the local Council of Governments-and with several years of experience under its belt, the District provided reliable growth information for the entire area. This data is still maintained and valid. The second source of information was developed in the late 1980's in conjunction with the growth management legislation. Over the last few years, during which the cities and counties have completed their comprehensive plans, population data and the projections of growth have become even more sophisticated and reliable. In order to establish overall populations and demands upon the wastewater system, the District has incorporated information from each of the six comprehensive plans which have been developed for its service area. Exhibit#2 presents both. population and wastewater flow figures for 1990, 1997 and 2000. It should be noted that the total population numbers have been tempered by one variable, that being the continued existence of septic tanks in a limited portion of the District. It should also be noted that the District's level of service standard (108 gallons per capita per day) has been employed in calculating flows in millions of gallons per day. The District's Level of Service Standard was originally developed in 1987 in response to the needs of the local cities and counties which were drafting their comprehensive plans. The standard is taken from nearly ten years of records which have been maintained by District personnel in a manner consistent with industry norms and regulatory requirements. The "Standard"was revisited in 1995 and modified to 108 gpcd from 85 gpcd. The following flow characteristics were important in determining the Level of Service Standard. Average Annual Day Flow- The total wastewater flow for the year divided by 365 days Peak Flow A three (3) month rolling average of.the monthly peak daily flow. • For the purpose of capacity analysis and demand determinations, the District uses the more conservative Peak Flow, which is also consistent with State permitting agencies. Correlation of the population serviced with flow demand measurements has resulted in the District's establishment of a Level of Service Standard of 108 gallons per capita per day. By way of example, the 1996 sewered population of 50,870 resulted in an actual per capita flow of 108 gallons per day or less, thus meeting the current Level of Service Standard. EXHIBIT 2 • LOXAHATCHEE RIVER ENVIRONMENTAL CONTROL DISTRICT PROPORTIONAL ALLOCATION OF WASTEWATER TREATMENT BASED UPON POPULATION PROJECTIONS BY ENTITY 1990 1997 2000 PEAK % of PEAK % of PEAK % of TOTAL POP.on POP.on FLOW TOTAL TOTAL POP.on POP.on FLOW TOTAL TOTAL POP.on POP.on FLOW TOTAL POP. SEPTIC SEWER MGD" FLOW POP. SEPTIC SEWER MGD FLOW POP. SEPTIC SEWER MGD FLOW JUNO BEACH 3,937 550 3,387 0.29 8% 4,422 480 3,942 0.43 8% 4,570 550 4,020 0.43 6% TEQUESTA 4,499 1,530 2,969 0.25 7% 4,723 1,510 3,213 0.35 7% 5,013 1,550 3,463 0.37 5% JUP INLET COLONY 390 390 0 0.00 0 390 390 0 0.00 0% 390 390 0 0.00 0% JUPITER 24,986 2,150 22,836 1.94 54% 33,335 2,695 30,640 3.31 63% 42,284 1,340 40,944 4.42 65% PALM BCH.CTY. 13,250 4,180 9,070 0.77 21% 11,778 5,409 6,369 0.69 13% 15,380 5,800 9,580 1.03 15% MARTIN CTY. 5,747 1,516 4,231 0.36 10% 6,450. 1,695 4,755 0.51 10% 7,273 1,845 5,428 0.59 9%• TOTAL 52,809 10,316 42,493 3.61 100% , 61,098 12,179 48,919 5.28 100% 74,910 11,475 63,435 6.85 100% • Uses'87 Level of Service factor III. DESCRIPTION AND INVENTORY OF PUBLIC FACILITIES The public facility which is owned, operated and maintained by the Loxahatchee River Environmental Control District is the Regional Wastewater System serving the municipalities of Jupiter, Tequesta and Juno Beach, along with the unincorporated areas of northern Palm Beach and southern Martin Counties. For the purpose of description in this report, the Regional Wastewater System consists of the following three components. A. Collection and Transmission System B. Treatment System C. Reclamation and Disposal System The collection and transmission component of the Regional Wastewater System is made up of gravity sewer lines, pumping stations and force mains which serve to collect wastewater from the various portions of the service area and transmit it to the Regional Treatment Plant. Exhibit#3 provides an inventory of these facilities and describes growth and expansion patterns of the past several years. Relative to capacity and demand, it should be noted that these facilities are designed and constructed to meet ultimate buildout capacities for the project, neighborhood, business park, etc. for which they provide service. The current and future demands placed on these pump stations and lines will vary dependent on the extent of development in the area to be served; however, it is most important to realize that demand does not exceed capacity: The design size of the facility is sufficient to meet any demand through buildout of the area. Exceptions could occur if the land use of a given area were to be altered and transmission facilities had been installed. This potential problem is guarded against through a close working relationship between District personnel and officials of the cities and counties. • EXHIBIT 3 LOXAHATCHEE RIVER DISTRICT ANNUAL GROWTH OF DISTRICT FACILITIES COLLECTION &TRANSMISSION SYSTEMS February, 1997 Oct. Nov. Nov. Nov. Nov. Nov. Nov. 1990 1990-91 1991 1991-92 1992 1992-93 1993 1993-94 1994 1994-95 1995 1995-96 1996 Gravity Lines Total Feet 873,703 895,773 913,773 929,473 953,195 961,748 968,033 Add for Period 22,070 18,000 15,700 23,722 8,553 6,285 %Change 3% 2% 2% 3% 1% 1% Manholes Total 4,132 4,235 4,320 4,465 4,619 4,651 4,691 Add for Period 103 85 145 154 32 40 %Change 2% 2% . 3% 3% 0.69% 0.86% Lift Stations Total 146 152 155 158 160 161 160 Add for Period 6 3 3 2 1 -1 %Change 4% 2% 2% 1% 0.63% -0.62% - Force Mains Total 311,596 316,496 320,696 325,541 332,523 350,165 .350,465 Add for Period 4,900 4,200 4,845 - 6,982 17,642 300 %Change 2% 1% 2% 2% 5.31% 0.09% IQ Mains Total 73,718 86,612 86,612 86,612 86,612 86,812 86,612 Add for Period 12,894 0 0 0 0 0 %Change 17% 0% 0% 0.00% 0.00% 0.00% • The Wastewater Treatment Plant is the most critical component of the full system. A single Regional Wastewater Treatment facility serves the entire District. All wastewater transported from the towns and unincorporated areas is treated at the plant which is located in the approximate center of the populated portion of the District. By way of definition, the Regional facility is an activated sludge, biological reaction facility using pure oxygen and followed by clarification. This secondary treatment phase is then followed by tertiary filtration and high level disinfection. The major portions of the treatment process are paralleled by redundant processes, full emergency power generation is available and the reliability of the entire system has received the State of Florida's highest rating. The current permitted capacity of the Wastewater Treatment plant is 8.0 million gallons per day (MGD), having completed construction of additional effluent disposal capability. Using the level of service standard of 108 gallons per capita per day (gcd), this permit capacity is sufficient to accommodate a population of approximately 74,000 or a projected sewered population, based on current projections, through the year 2004. • Projected demand for wastewater service is expressed on Exhibit#4 under both average and peak conditions. The average demand is calculated by taking the projected populations times a factor of 100 gcd which is a norm which has been developed over the past several years. The peak demand is calculated by taking the projected populations times 108 gcd which is the level of service standard developed through past experience and presented for use by each of the multi-jurisdictional governments in the formulation of their comprehensive plans. It should be noted that the District has also employed other, less conservative means of projecting future demands; however, when planning, designing and permitting for new facilities is considered, the more conservative means is deemed appropriate. The original treatment plant began operations in 1978 and recent expansions were completed in 1996. The plant is, therefore, relatively young and, as such, the condition is excellent and renewal and replacement needs remain relatively low. The final component of the Regional Wastewater System was the reclamation and disposal facilities. Over the past ten years, there has been an environmentally progressive movement in the disposition of treated effluents from wastewater treatment facilities. Older technologies of surface water discharge, ocean disposal or deep well injection are giving way to water reuse options such as low rate irrigation of turf grass areas. The Loxahatchee River Environmental Control District has been a leader in this movement and has operated a nationally recognized reuse program since 1984. The program has been so successful that no discharges to the surface waters of the area have been necessary for over 122 months. The present capacity of the reuse system is limited to 9.0 MGD based on the amount of installed filtration capacity. When the regulatory community evaluates disposal capacity of a facility, they remain conservative and discount reuse systems in favor of systems such as deep injection well. While this practice may be modified, the backup disposal system for the District is important as it relates to capacity evaluation. The District operates a 12.4 MGD deep injection well, with pumping capacity sufficient for a rating of 8.00 MGD As can be seen from Exhibit#4 and will be discussed in subsequent sections of this Report, no expansions of current facilities are needed within the next five years. However, plant expansion from 8.00 MGD to 10 -12 MGD will be needed for growth beyond the 2003 - 2004 time frame. EXHIBIT 4 WASTEWATER TREATMENT DEMAND vs. CAPACITY 8.00 8.00 - 6.86 7.00 -- C.61 6.00 ..28 ~ / .89 To 5.00 0 0 4.00 —AVG DEMAND —PEAK DEMAND CAPACITY 3.00 ' ' 2.00 i — — —t -- -+- i — - — i — —f- — I a — i — i — 1 1990 1991 1992 1993 1994 1996 1996 1996 1997 1998 1999 2000 YEARS • IV. PLANS FOR CAPITAL IMPROVEMENTS Over the past 7 years the District performed expansion of the central components of the regional wastewater treatment facility, providing: Treatment Plant 8.0 MGD Reuse Water 9.0 MGD Effluent Disposal 12.54 MGD With this phase of construction complete, additional capacity is not needed for several years. Current plans call for the next phase of treatment plant expansion to commence in 2000, and be completed by 2003. The source of financing for all projects is cash which is now in hand and unrestricted, or the proceeds of a recent Bond issue that can be drawn against over the \next three years. Included in Exhibit#5 are annual draws of$2.4 million in 1997, and $1.9 million in 1998 and 1999 for the costs of neighborhood sewering. The Bonds will be retired by the payment of assessments from the subject areas. Major Capital Projects anticipated for the next year include: return activated sludge (RAS) treatment at the plant, and the sewering of neighborhoods on the Tequesta Peninsula (Anchorage Point, Bermuda Terrace, Bay Harbor, Cove Point (Martin County)). The sewering of the Tequesta Country Club is anticipated to commence in fiscal year 1998. Additional sewering projects are included in the Capital Collection & Transmission system (CAP IMP C&T) expenses in Exhibit#5, though not specifically identified at this time. With specific regard to Renewal and Replacement, it should be noted that no substantial projects are scheduled through 2000. By viewing the R&R column of the District's financial plan, Exhibit#5, one can see that normal renewal and replacement work should continue through the end of this decade, however with the aging of facilities and the costs of relocation where facilities are permitted within roadways slated for expansion the Revenue & Expense Analysis has included an escalation in the costs of R&R and funding of this account for the future. EXHIBIT 5 • LOXAHATCHEE RIVER ENVIRONMENTAL CONTROL DISTRICT REVENUE&EXPENSE ANALYSIS j EXPENSES REVENUE AD CASH M,ENG R BOND C C&TIP TRT/DISP alit EXPN E RATES CHAP IMP TOTAL SEWER RGE$ A FEES G FEES FEES CHARGE CHARGE R VENU R. VENU INTRST REVNU I.Q. MISC PLANT LINE ASSMNT PRE-INT TOTAL �F OW CASHN YR END • • OPER 5 54,207 $850 $225 $2,195 $553 $8,030 $5,350 $284 $68 $438 $68 $825 5188 $7,221 5509 $7,730 ($300) $8,030 6 $4,870 5618 $1,116 $70 $513 $7,387 $5,457 5272 $123 $413 $93 . $680 5238 $57 $7,333 $479 $7,812 $425 $8,455 )7 55,294 $2,727 $1,970 $478 $540 $11,009 $5,545 $311 $101 $420 $54 $1,330 $404 $130 $8,295 $412 $8,707 ($2,302) $8,553 )8 $5,718 $1,940 $1,000 5250 $850 $9,758 $5,810 $336 $112 $475 $57 $1,528 $808 $151 $9,077 5599 $9,875 ($83) 59,770 19 $6,175 $1,940 $1,900 5250 $890 $11,155 56,021 $367 5112 $551 $60 $1,719 $689 $176 $9,695 $684 $10,379 ($776) $10,294 )0 $8,669 $3,600 $1,800 ;:' $600';: $940 $13,609 56,634 $379 $126 $575 $63 51,858 $656 5688 $10,977 $721 $11,698 ($1,911) $8,383 )1 $7,202 $400 $1,180 $1,100; ; $980 $10,862 $6,887 $370 $126 $585 566 $1,858 $743 $499 $11,134 $587 $11,721 $859 $9,241 )2 $7,779 5400 $280 :::$2,000 :`•: 5980 511,439 $7,567 $353 $126. $588 $89 $2,007 $755 $502 $11,987 $647 $12,614 $1,175 $10,416 )3 $8,401 $400 $280 :�52,500 5980 $12,561 $7,834 $235 $126 $591 $72 $2,007 $850 • $506 $12,221 5729 $12,950 $389 $10;805 TAL $47,236 $11,407 $8,410 $7,178 '$6,160 $80,393 $46,298 $2,351 $829 $3,785 5439 $12,307 $4,705 $2,650 $73,364 $4,379 $77,743 V. CAPACITY COMMITMENTS AND RESERVATIONS Commitments of capacity in the Regional Wastewater System of the District are made only by the execution of a Developer Agreement and the payment of certain charges in accordance with Chapter 31-10 of the Florida Administrative Code. These charges presently equate to approximately $1,700 per typical residential dwelling unit. Over the past 21 years, in excess of 450 Developer Agreements have been executed with the District reserving capacity of over 6 MGD for nearly 60,000 people. While most of these past reservations have since connected to the Regional Wastewater system, some 55 Developer Agreements remain active and are reserving an additional capacity for about 5,000 new people. The following table provides a summary of the capacity commitments and the status of those commitments in terms of • population and wastewater flow in gallonage. A brief explanation of the various categories of commitment/reservation also follows. MAX. MO. FLO % of POP. IN MGD CAPACITY PERMITTED CAPACITY 74,070 8.0 100 EXISTING CONNECTIONS 48,919 5.28 66 APPROVED CONNECTIONS 3,106 0.33 4 • POTENTIAL CONNECTIONS 4,998 0.53 7 APPROVED COMMITMENTS 52,025 5.61 70 POTENTIAL COMMITMENTS 57,023 6.47 81 • Existing connections are those connections which are currently installed and active. • Approved connections are those connections which have a line available currently and are not yet connected or, construction plans have been approved for the installation of lines. • Potential connections are those connections which have reserved capacity under a Developer Agreement, but have not yet received approval of construction plans. • Approved commitments are the combination of Existing and Approved connections. • Potential commitments are the combination of Existing, Approved and Potential connections. As observed in the above calculations, if all present reservations were to build out, the total population served, just over of 57,000 would only consume 81% of the capacity of the Regional Wastewater System. In recognition of the future demands for capacity, the plant facility has been expanded incrementally over the past decade to meet the projected needs. The increased capacity that is now available will provide capacity for approximately 15,000 persons more than is needed to meet current demands plus the build-out of all reservations. The length of time for which each commitment or reservation remains active is solely dependent upon the developer maintaining the terms and provisions of the agreement, specifically the payment of continuing fees. Once the Developer Agreement is executed, a continuing quarterly Service Availability Standby charge is required to keep the agreement in good standing. The reserved commitments will be maintained as long as all charges are paid on the pre-established schedule. Upon failure of a developer to make payments under the agreement, the agreement is defaulted and any unused connections become available for re-allocation by the District. . As the.Regional provider of service for an area larger than internally located municipalities, the District does not possess a means nor need to specifically break out the commitments and reservations by political subdivision. Therefore, no direct accounting of commitments is made for the cities and counties included within the Districts service area. However, a review of Exhibit#2 shows the anticipated allocation of wastewater service capacity for each of the six separate municipal and county governments within the Loxahatchee River District service area. • VI. CONCURRENCY MANAGEMENT PROCEDURES The methodology for determining available capacity has been outlined in the proceeding sections. Specifically, the full capacity of the Regional Wastewater facility will continue to be established by the Florida Department of Environmental Protection under its permitting procedures and, the actual measurement of demand will be recorded based on observed flowage in MGD and by monitoring the established level of service standard. The available capacity, therefore, is precisely determined by subtracting the capacity used from the full capacity. Using 1996 data, the 8.0 MGD capacity less the 5.28 MGD peak demand for service leaves 2.72 MGD of available capacity. This available capacity, in gallons, can be converted into future population by dividing by the District level of service standard of 108 gallons per capita per day resulting in available capacity for 25,185 new residents. An annual review will be performed to continually confirm the appropriateness of these procedures and to monitor the changes in available capacity. Additionally, the District will continue to coordinate planning efforts with the cities and counties to assure proper application of the procedures and standards. The procedure for reserving committed capacity will not change and will continue to be made only through the execution of a Developer Agreement. The key to the successful implementation of these management procedures is the continued communication with the governments responsible for making the concurrency determinations. As of this writing, the District has already developed, in concert with the effected governments, and acceptable procedure and format for the needed communication. f VILLAGE OF TEQUESTA rILt t;UrI DEPARTMENT OF COMMUNITY DEVELOPMENT Village of Tequesta '• ' _f Post Office Box 3273 • 357 Tequesta Drive s"�Rl� a Tequesta, Florida 33469-0273•(407)575-6220 eI 0:` Fa.: (407) 5;�239 FF R 1 7 1997 e. ccy% `I ';i;!abe Manager's Office ) February 11, 1997 • Clinton R. Yerkes, Deputy Director Loxaha t chee River District 2500 Jupiter Park Drive Jupiter, FL 33458-8964 Re: 1996 Public Facilities Report Dear Mr. Yerkes: The Village of Tequesta has begun the process to prepare the Villages EAR based amendments to our Comprehensive Development Plan as required by State Statutes. The review team which; consists of Village Staff and Planning Consultants have been reviewing the Districts 1996 Public Facilities Report in order to see if we need to amend, add or delete any Goals, Objectives or Policies in the Sewer Element of the Villages Comp Plan. As a result of our review of your Public Facilities Report, it has, been identified that the Report lacks specificity with regard to the section on page 12 that deals with Renewal & Replacement -and to Exhibit 15, Revenue & Expense Analysis. It would be much more helpful to the Village if the Report set forth a schedule. of Renewal & Replacement that was specific to the Village of Tequesta. The Report should state when, where and how much, such as, what month & year, what location within the Village, and what the anticipated costs would be for Renewal' or Replacement of a particular System structure or device, such as a sewer main, ._lift station, sewer manhole, etc. A very important reason for this request, is so that the Villages Director of Public Works will know when and where to schedule the road & street repaving program within the Village. Over the next 5 & 10 year Capital Improvement periods, the Village will be systematically repaving all of the Villages roads & streets. It would be extremely helpful if the District would provide a schedule of dates & locations for your anticipated activities with regard to Renewal & Replacement in order that the Village schedule our repaving program and other work within our Rights of Way more effectively and efficiently. Please respond to this request for a Public Facilities Report with more specificity, as discussed above, in a timely manner so that the Village can adjust any Policies and Time frames in the Sewer Element and Capital Improvement Element prior to submitting the Recycled Paper • Page 2 Cinton R. Yerkes February 11, 1997 Villages EAR based Amendments to the State. These requested ' enhancements to the Public Facilities Report in order to add more specificity will also be helpful when the Village prepares its Annual Concurrency Management Report. Thank you for your prompt attention to this important Village matter. If you have any questions regarding any of the contents of this letter, please contact me at the letterhead address or at 575- 6220. Sincerely, 1 u.tt cYCIA Scott D. Ladd, CBO Building Official and Comprehensive Planning Coordinator SDL/sdl • C: Thomas G. Bradford, Village Manager Jack L. Horniman, Planning Consultant Damian A. Peduto, Planner Richard C. Dent, Director, Lox. River District