Loading...
HomeMy WebLinkAboutDocumentation_Regular_Tab 8A_3/7/1996 4 . llIELv1 MEMO vll--a------...a.. %,1111... 1 To: Thomas G. Bradford, Village Manager From: Carl R. Roderick,Chief of Police Subject: Lightning Protection System. Date: February 29, 1996 Over the past few years, the main building has received several lightning strikes"that have caused major damage to the E9-1-1 system,computers and phones. Because of the age of the building, the electrical grounding system is less than adequate, which is the main problem. We have installed extra ground to the E9-1-1 equipment but the office machinery is still vulnerable to electric spikes caused by lightning. The system that is proposed will ring the roof of the building with conductors (they will be tied into the antenna system as well) and will direct any lightning charge to ground, this system being the least path of resistance. There is no guarantee on any system when you take a direct hit from a strong lightning charge. , • MEMO To: Thomas G. Bradford, Village Manager From: Carl R. Roderick,Chief of Police oCt Subject: Lightning/Ground Protection quote. Date: January'l 1, 1996 I spoke with Dennis Dillon of Bonded Lightning Protection Systems and he advised that the quote issued on October 9, 1995, is still good. MOHD [ED • LIGHTNING PROTECTION SYSTEMS ' CO NTRACTORS-ENGINEERS ll J ri P.O. BOX 9008•JUPITER,FLORIDA 334684006 TELEPHONE:(407)748-4136. FAX:(407)7474233 BE 17682 ESTIMATE & AGREEMENT • Village of Tequesta - DATE: . October 9, 1995 q P 0 Box 3273 PROJECT: Village of Tequesta Tequesta, FL 33469 LOCATION: Tequesta, Florida L *_ 1 QUOTATION FOR L.P.SYSTEM SEE BELOW DOLLARS, , (S REF.SPEC. • REF. DWGS. 0 CONFIRMING OUR TELEPHONE QUOTATION • QUOTATION FOR GROUNDING SYSTEM 0 WE ARE PLEASED TO QUOTE YOU DOLLARS, (S 0 CONFIRMING OUR VERBAL AGREEMENT REF.SPEC. REF. DWGS. • • TERMS: NET 30 DAYS Gentlemen: Bonded Lightning Protection, Inc. will furnish and install a complete and adequate Lightning Protection and/or Grounding System for the above Referenced Project in strict compliance with th 'lob Specifications, all Related Plans, and the Code Requirements as set forth by the Under- writers' Laboratories, Inc., U.L. 96A. latest edition and the National Fire Protection Association, • NFPA No. 78, latest editio . Our Quotation as listed above includes, all labor and materials, unless exceptions taken as noted below, insurance,applicable taxes,test,shop drawings and Exoefitiolti taken: - P olice._ Dept./City Hall E +ire Station/Living Quartors Bldg. : $4..800.00. Building & Zoning./tlatpr Thaviiii4parkt n1dg_ _ SL 5501 41)._ ACCEPTANCE OF SID The above specifications,terms and contract are satis- factory, and we hereby authorize the performance of Very truly yours, this work. AIA Subcontract Document A401 to be- come a part of this agreement. BONDED LIGHTNING PROTECTION SYSTEMS Company • Signed Dennis P. Dillon Date This contract is void 60 days from date unless oink copy is signed & returned.