HomeMy WebLinkAboutDocumentation_Regular_Tab 21_10/9/2025 Agenda Item #21.
Regular Council
STAFF MEMO x
Meeting: Regular Council - Oct 09 2025
Staff Contact: Doug Chambers, Director of Public Department: Public Works
Works
Consider The Replacement of Outdated Parks and Recreation Structures at Tequesta Park
. -
Project Background
The Parks and Recreation Department proposes the construction of a new Operations and Storage
Facility at Tequesta Park to replace three existing, aged wooden structures. These structures—used
for staff operations, equipment storage, and seasonal materials—are over 50 years old, deteriorating
rapidly, and no longer compliant with current building or safety codes. They are unfit for staff
occupancy and incapable of securing valuable assets from theft, weather, or hurricane damage.
Purpose of the New Facility
The proposed facility will serve as a centralized, code-compliant structure to:
• Store specialized landscaping and field maintenance equipment (e.g., zero-turn mowers, reel
mowers)
• House event and recreation program equipment and supplies
• Provide secure storage for seasonal decorations and field tools
• Support staff with a small office and operational space
• Improve protection for Village assets and ensure safer, more efficient working conditions
The building will be engineered to withstand 180 mph winds, fully complying with Florida Building
Code wind-load requirements. It will sit on a newly constructed concrete slab foundation.
Proposal Review
Three quotes were obtained from qualified vendors. Below is a comparison of key details:
1. Eversafe Buildings — Recommended Vendor
• Building Size: 40' x 80' x 14'
• Price (after discount): $53,078.00
• Includes:
o Free delivery and installation
o Two 12' x 14' and two 10' x 10' roll-up doors (with chain hoists)
o Walk doors and windows
o Concrete anchors
o Engineered stamped drawings
0 40-year panel warranty, 20-year rust-through frame warranty, 12-month workmanship
warranty
o Free installation on owner's pad
• Notes: Best value based on price, comprehensive warranty, and inclusion of installation
Page 717 of 735
Agenda Item #21.
Arco Building Systems
• Building Size: 40' x 80' x 14'
• Total Material Price: $69,145.51
• Does NOT include:
o Installation
o Anchor bolts
o Foundation or concrete work
• Extras:
o $650 additional for stamped foundation drawings
o $5,580+ for roof/wall insulation (not included)
o Roll-up doors and windows must be supplied by others
• Warranty: Not clearly defined in the proposal
SteelMaster Buildings
• Building Size: 39'10" x 60'5" x 15'9"
• Price: $51,000 base for 60' length; $63,000 for 80' length
• Does NOT include:
o Installation
o Concrete or slab
o Roll-up garage doors
• Includes:
0 40-year mill-backed warranty
o Delivery and stamped engineered drawings
• Notes: Limited in scope and size compared to the others; significant elements excluded
Replacing the existing structures with a professionally installed, hurricane-rated steel facility will
greatly enhance the efficiency, safety, and security of Parks and Recreation operations.
This document and any attachments may be reproduced upon request in an alternative format by
completing our Accessibility Feedback Form, sending an e-mail to the Village Clerk or calling 561-
768-0443.
BUDGET AMOUNT $250,000 AMOUNT AVAILABLE EXPENDITURE AMOUNT:
$250,000 $45,073.80
FUNDING SOURCES: 303-323-663.672 IS THIS A PIGGYBACK:
❑ Yes ❑x N/A
DID YOU OBTAIN 3 QUOTES?
❑ Yes ❑x N/A
QUOTE 1 - BUSINESS NAME Eversafe QUOTE AMOUNT $45,073.80
QUOTE 2 - BUSINESS NAME Steel Master QUOTE AMOUNT$51,000.00
QUOTE 3 - BUSINESS NAME Arco Building QUOTE AMOUNT $69,145.51
Systems
Page 718 of 735
Agenda Item #21.
COMMENTS/EXPLANATION ON SELECTIONStaff recommends awarding the contract to Eversafe
Buildings based on overall best value, as their proposal includes installation, stamped engineering
drawings, and industry-leading warranties—all at the lowest cost—while other proposals exclude
installation and key components.
Staff recommends approval of the Eversafe proposal and to proceed with planning, permitting, and
implementation.
Eversafe Buildings Quote (40x80x14) R5
Color Chart
PICTURE OF MAINTENANCE FACILITY
STEEL MASTER TEQUESTA PARK MAINT FACILITY
ARCO BUILDING 40x80 Quote 9.30.25
Teguesta Park Maintance Building Locations
Page 719 of 735
�� �TEEL BUILDING PROPOSAL A+
A^0; � 2RSAFE BUILDINGS 1 11175 CICERO DR STE 135 1 ALPHARETTA,GA 30022 BBB
BUILTSAFE BUILTSTRONG BUILTTOLAST PH:1-800-374-7106 1 FAX:1-800-374-4694 1 WWW.EVERSAFEBUILDINGS.COM
A Longlif,Steel Buildings company
CUSTOMER: QUANTITY DESCRIPTION
Doug Chambers BUILDING DETAILS
DATE_: 40'x 80'x 14'Large Span Building
10/2/2025 2 Full Sides With Upgraded Vertical Sheeting&Wainscot Finish(Includes Hat Channels)
1 Full End With Upgraded Vertical Sheeting&Wainscot Finish(Includes Hat Channels)
ADDRESS: 1 Full End With Upgraded Vertical Sheeting&Wainscot Finish(Includes Hat Channels)
TBD Upgraded Vertical Roof With 6"Overhang(Vertical Roof Includes Hat Channels&Ridge Cap)
CITY/STATE:
Jupiter,FL Heavy Duty 26 Gauge Roof And Wall Sheeting
ZIP:
33469
COUNTY:
Palm Beach
PHONE
(561)769-0483
E-MAIL:
dchambers@tequesta.org
BUILDING TYPE: ACCESSORIES
Large Span Building 1 12'x 14'High Impact Heavy Duty Lockable Roll Up Door w/45 Degree Angle Cuts(With Chain Hoist)
ROOF SIZE: 2 10'x 10'High Impact Heavy Duty Lockable Roll Up Door w/45 Degree Angle Cuts(With Chain Hoist)
40'x 81' 1 10'x 10'High Impact Heavy Duty Lockable Roll Up Door w/45 Degree Angle Cuts(With Chain Hoist)
BUILDING SIZE:
40'x 80' 1 Roll Up Door Side Frame
WALL HEIGHT: 4 Seals for Roll Up Door(Top&Sides)
14'
ROOF PITCH:
2/12
ROOF TYPE: 1 Heavy Duty Walk Door With Keyed Lock-36"x 80"High Impact(Solid) (Installed on side of building)
Upgraded Vertical Roof With 6" 1 30"x 30"High Impact Single Hung Window
Overhang
1 Window Side Frame
FRAME TYPE:
Heavy Duty 14 Gauge Galvanized
Large Span Steel Truss Frame With
Double Legs
FRAME SPACING:
4'On Center Concrete Anchors
SHEETING TYPE:
Upgraded Heavy Duty 26 Gauge
Galvanized Steel
CERTIFICATION:
Risk Cat 2 Commercial
ADDITIONAL NOTES: Foam Enclosures-Ridge and Eaves
MISCELLANEOUS
*Buyer must have a Reach Lift with a 42'reach and
6,00011b pound capacity on site for installers during the Certified Building
installation process.Any rental or use fees incurred are As Built Stamped Drawings(2 Sets)
Buyer's responsibility.(Est.$1,200-1,500/week rental
fee(.Rental can be arranged.
FREE DELIVERY TO JOBSITE
FREE INSTALLATION ON YOUR PAD
NOTE:BUILDING WILL BE CERTIFIED FOR UP TO
170MPH AND COMPONENTS MUSTBE HIGH IMPACT. FREE COLOR MATCH FASTENERS
***40 YEAR LIMITED WARRANTY ON PANELS***
***20 YEAR LIMITED RUST THROUGH WARRANTY ON FRAME AND ROOF***
***12 MONTH WORKMANSHIP WARRANTY ON BUILDING***
Note:Discount Good Until: Building Price $65,785.00
*Buyer must provide a tax exemption Monday,October 20th,2025 20%Discount -$13,157.00
certificate to be eligible for tax exemption. ***We can arrange to have your building permits pulled(building&concrete or i*** Additional Labor $400.00
Payment requirements: BUILDING PRICE(AFTER DISCOUNT) $53,028.00
$8,704.20 due now *Sales Tax(0.00%) $0.00
Drawings(Commercial) $750.00
$22,536.90 due at scheduling of installation Total $53,778.00
$22,536.90 due immediately following installation Due Now** $8,704.20
PREPARED BY: 'Permit fees are not included BALANCE(See Payment Breakdown) $45,073.80
William French
*Eversafe has the right to correct any content or pricing errors on this quote Page 720 of 735
Agenda Ite #
EVEMAFE
BUILT SAFE BUILT STRONG BUILT TO LAST
BRITE WHITE IVORY LIGHT STONE SAHARA TAN
E
LIGHT GRAY CLAY HAWAIIAN BLUE BRIGHT RED
BARN RED BURGUNDY IVY GREEN BLACK
•
BURNISHED SLATE COCOA BROWN CHARCOAL GALVALUME
1-800-374-7106
www.eversafebuildings.com
•
AMERICAN MADE-AMERICAN PROUD
*Colors shown represent finish colors as accurately as possible.However,colors may vary slightly on actual building.Digitial depictions of colors may
appear different depending on the device used to view them.Similarly,print quality can change the appearance of printed depictions.If color choice is
critical,please request a metal color sample.Eversafe is not responsible for such variations in color.
• • • 0 2025 Eversafe Buildings
Agenda Item #21.
{
4b
.r
� I
ryl � u
3 f '
Lj
Page 722 of 735
Agenda Item #21.
�SteelMaster
S R.r Iq[ILI!LDINC,
www.Steel MasterUSA.com
Building Proposal
1023 Laskin Road,Suite 109
Virginia Beach,VA 23451
1-800-341-7007telephone
1-757-422-9167fax
Prepared For: Doug Chambers
Village of Tequesta
Jupiter FL 33469
Tel #: 561-768-0483
Email: dhaambers@tequesta.org
Prepared By: Christin Day, Project Specialist
Date: 10/l/25
Division: Commercial/Industrial Division
Quote firm until: 10/31/25
Building S Model Price (not incl FL tax)
540-16-60 Approx Weight: 14, 000 lbs. $51, 000.00
-----------------------------------------------------------------------------
Dimensions:
39'-10 . 625" wide x 15'-9. 625" high x 60'-5" long
All Building Materials Include:
• Arches: (30) Grade 80 heavy duty Heavy gauge silver steel arches, AZM 180/AZ 60
Galvalume Plus coating, double bolt 9" lap seams.
• Front End Wall: Solid end wall with (1) framed opening, measuring 10'w x
10'h. Includes header beam, canister door support posts, and end wall
trim.
• Rear End Wall: Solid end wall with (Qty.l) outer angle trim flange.
• Service Door: (1) 30 .5"w x 79.5"h Conventional Door with lockset.
• Industrial Base Connector: Industrial 14 gauge Galvalume Plus base plate
• Premium Grade Hardware: 5/16" Grade 2 preassembled fasteners with polyethylene
washers to secure the building components through predrilled holes.
• Exclusion: Anchor Bolts, garage door, construction/assembly.
• Drawings: (Qty.3) Complete Sets of Engineer Stamped Shop Drawings.
• Warranty: 40-year non-pro-rated mill-backed warranty.
• Delivery: Included to jobsite location in Jupiter, FL.
• Optional Add On: To change the length to 80'1 you are looking at $63,000
delivered before taxes.
Terms & Delivery Schedule
Payment Terms
25% deposit required with order placement. Balance to be paid on delivery.
Shipping
Please allow six to eight weeks for delivery of materials. Materials will be
delivered via flat bed truck. Customer is responsible for unloading of truck.
Page 723 of 735
Agenda Item #21.
(Steel
s nc:i�otad�v�^a�s
www.SteelMasterUSA.com
Arch Design Specifications (IBC15- Cat I)
Ground Snow Load: Palm Beach CO, FL (0 PSF)
Wind Load: Palm Beach CO, FL (153 MPH)
Live Load: Palm Beach County, FL (0 PSF)
SteelMaster
Terms and Conditions
This order is subject to price increases if delivery of the building is more
than 60 days after order date.
1. DEPOSIT --The deposit shall be held by the seller as security for the
completion of Buyer's duties under this contract. The deposit shall not be
refunded to the buyer except in the event of a material breach by Seller
of this contract. In the event of a material breach of the contract by
Buyer, Seller, at Seller' s option, shall have the right to (1) retain the
deposit as liquidated damages or, (2) retain the deposit and pursue all
other rights and remedies shall be cumulative and not exclusive of any
other such right or remedy.
2. PAYMENT -- Payment of the total purchase price, less the amount of the
deposit, is to be paid COD upon delivery of goods to the buyer. Buyer
hereby grants to the seller a security interest in the structure to secure
payment as set forth in this contract.
3. SHIPMENT -- This is not a delivery contract unless otherwise specified and
regardless, delivery is not guaranteed to the location specified but
rather delivery will be as close to said address as reasonable in the sole
discretion of the freight carrier. Seller shall not be responsible for
the delivery of goods at any place other than the manufacturer's place of
business. Buyer, upon being notified that the goods are ready for shipment
shall receive and accept delivery of goods within 14 days of such
notification. If buyer fails to accept delivery of the goods within two
months from the expiration of said 14-day period Seller may at its option
and without notice treat this agreement as being materially breached in
which event seller shall have all remedies provided by law for breach of
contract. If Buyer picks up goods at Seller's factory or if Buyer elects
to use a carrier of Buyer' s choosing, Seller shall not be responsible for
loss or damage of goods in transit.
4. WARRANTIES -- Seller warrants that its goods are as described in the quote
document previously provided and are free from any defects in material or
workmanship. SELLER MAKES NO OTHER WARRANTEE, EXPRESS OR IMPLIED, AND ALL
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
WHICH EXCEED THE ABOVE OBLIGATION ARE HEREBY DISCLAIMED. ANY RUST
PERFORATION WARRANTY WHICH BUYER MAY RECEIVE IS GIVEN DIRECTLY BY THE
MANUFACTURER TO BUYER AND IS NOT GIVEN BY THE SELLER.
5. SELLER'S LIABILITY -- In the event of any breach of seller's warranties
and in full satisfaction of all incidental damages, Seller, at its option,
will either replace the defective or nonconforming goods or refund the
purchase price for such defective or nonconforming goods, upon the return
thereof to seller. Seller will not be liable for consequential damages and
under no circumstances shall its liability exceed the purchase price for
defective or nonconforming goods. Seller shall have no responsibility or
Page 724 of 735
Agenda Item #21.
r mu'*
IR.CH 0 V L0 ass
www.SteelMasterUSA.com
liability whatsoever for the erection of the structure or structures which
are the subject of this agreement or for the selection of a contractor to
erect the structure or structures. Seller is in no way responsible for
damage that may result to a buried building unless the building has
specifically been designed for this purpose as clearly indicated in this
agreement. It is specifically agreed that the foregoing remedies are
exclusive and in substitution for all other remedies to which the buyer
would otherwise be entitled. Seller shall be given a reasonable
opportunity to investigate all claims or complaints and no goods may be
returned to seller without the written approval of seller. Any claim will
be conclusively deemed waived unless written notice thereof is given to
the seller within thirty (30) days following the receipt of the goods.
6. SOIL CONDITION & FOUNDATION -- It is the sole responsibility of the buyer
to assure that soil and subsoil conditions at the site location are of
sufficient density to support and sustain pressures and forces exerted
thereon by the foundation, the building purchased, and the type and
quantity of the material stored therein. The buyer of the building to be
constructed is responsible for following and complying with the
specifications and instructions contained in the manual supplied to buyer.
7. RISK OF LOSS -- Seller shall not be responsible for loss or damage to
goods in transit or during erection or construction. In case of loss or
damage, claims must be made against the carrier or erection contractor by
the buyer.
8. VENUE -- This contract shall be governed by and construed in accordance
with the laws of the Commonwealth of Virginia. Buyer agrees that any suit
or action arising out of or relating to this contract shall be instituted
exclusively in the Courts of the City of Virginia Beach, Virginia. Buyer
hereby waives any objection it may have to the laying of venue in such
court.
9. FORCE MAJEURE -- Failure of Seller to make, or Buyer to take, all or any
part of any shipment hereunder, if such failure is due to acts of God,
war, labor difficulties, breakdown or damage to Seller's plant facilities
or Buyer's receiving facilities, embargoes, shortages of raw materials or
transportation equipment, compliance with any law, regulation or order of
any public authority and any cause beyond either party's control shall not
subject party to any liability to the other party.
10.NOTICES -- All written communications or required notices between
SteelMaster and the Buyer shall be sent by first class mail, postage
prepaid, or by nationally recognized overnight delivery to the address, or
to the facsimile listed below: Communications shall be signed and sent:
If to SteelMaster: SteelMaster Buildings, LLC
1023 Laskin Road, Suite 109
Virginia Beach, VA 23451
757-422-6800 telephone
757-422-9167 facsimile
If to Buyer: (Insert Applicable name)
Page 725 of 735
Agenda Item #21.
(Steel
s nc:i�otad�v�^a�s
www.SteelMasterUSA.com
SteelMaster Buildings® Technical Specifications
Re: Clear Span Arch Type Steel Structure
General Requirements:
Scope. This specification covers the design, material, manufacture, as well
as shipping and handling of clear span arch type steel structure. Depending
upon specific model, each arch section will be 24" center to center of
fastening holes once constructed. The interior of the structure below the
steel arch shall be clear and free of any structural members and shall
provide unobstructed floor space. The structure shall also include all
accessories and items required and necessary for the scope and stated use and
as herein specified.
Dimensions:
The structure shall have the following approximate minimum exterior
dimensions:
Overall Width: 39'-11"
Overall Length: 60'-5"
Peak Height: 15'-9"
Operation and Use:
The structure provided by SteelMaster BuildingsO shall be designed to provide
a minimum 30-year operational use period in normal conditions. The structure
shall be capable of being assembled, operated and dismantled in all ambient
temperatures between -20 F and 120 F.
Design Criteria:
Building design shall comply with the structural requirements of the latest
adopted version of the International Building Code (IBC) . Designs conform
also to "Minimum Design Loads for Buildings and Other Structures" published
by the American Society of Civil Engineers (ASCE 7) and the "Specification
for Design of Cold-Formed Steel Structure Members" published by the American
Iron and Steel Institute (AISI) . Since SteelMaster arch panels contain
numerous stamped transverse stiffeners, AISI requires that the design
strength of SteelMaster arch panels shall be confirmed by test results.
All structures structural design calculations and foundation designs are in
accordance with recognized code standards using methodology from ASCE 7 . The
structure shall comply with current issues of AISC, AISI, NEMA, and ASTM
specifications, as design loads given. Appropriate safety factors must be
maintained. Wind load factors and coefficients used in design of the arches
must be in accordance with ASCE 7 .
Page 726 of 735
Agenda Item #21.
rt o I ter
IR.CH 0 V L0 ass
www.SteelMasterUSA.com
All design certifications are signed and sealed by a registered Professional
Engineer. Also, reaction diagrams for independent foundations designs can be
provided when it is specified at time of purchase that a custom foundation
will be implemented.
A total of 13 basic load cases and 55 load combinations shall be used to
design SteelMaster Buildings.
Wind Loads:
The arches shall be designed to be capable of withstanding 3-second gust wind
loads from any direction. The structure shall be designed using an exposure
category "C" for determining design wind pressure on the arches. The
methodology is to be taken from ASCE 7 .
Exposure C is defined as open terrain with scattered obstructions having
heights generally less than 30 ft. This category includes flat open country
and grasslands.
Ground Snow Loads:
The SteelMaster structure shall be designed to meet or exceed all local snow
load requirements. Unless otherwise specified, the building shall be designed
for Importance Category 1 usage. The distribution of loading shall be in
accordance with the International Building Code and applicable design
standards.
Live Loads:
At a minimum, the SteelMaster structure shall be capable of supporting a roof
live load of twenty pounds per square foot projected over the entire
structure and any probable arrangements of loading resulting in the highest
stress in the members.
As defined by IBC, live loads are those loads produced by the use and
occupancy of the building and do not include dead load, construction load, or
environmental loads such as wind load, snow load, rain load, earthquake loads
or flood loads. ASCE 7 further clarifies that live loads on a roof are those
produced (1) during maintenance by workers, equipment, and materials; and (2)
during the life of the structure by movable objects such as planters and by
people.
Seismic Loads:
Seismic loads and designs shall be based on the requirements of the
International Building Code & ASCE 7 .
Foundation Design:
SteelMaster will provide foundation design details to the purchaser to meet
the structural requirements and accord with the boundary conditions of the
building. Where a custom foundation design is to be implemented, SteelMaster
will revise the arch designs and provide the arch reactions required for the
foundation design.
Materials Specifications:
Page 727 of 735
Agenda Item #21.
KON
SteeflMaster
sprIi 0 V dam s
www.SteelMasterUSA.com
All materials used in SteelMaster structures shall be new, without defects,
and free of repairs. The quality used in the structure shall be such that the
structure is in conformance to the performance requirements specified herein.
Metals:
All metal components of the structure including, but not limited to, the arch
panels, end wall panels, specialty foundation base connectors, and other
framing materials are fabricated from Heavy Commercial AZ 180 g/mz minimum
triple spot Galvalume Plus coating, in accordance with ASTM A 792 & A792M
Grade 50 minimum with a 50 ksi minimum yield, and 65 ksi minimum tensile
strength.
Coating:
Galvalume Plus has a clear, organic resin coating, which is applied to both
sides. Once applied the coating is then thermally cured. Galvalume Plus
provides a bright, attractive appearance with a fine spangle and gentle
sheen. Galvalume Plus steel will be used for gauges 22-11 and G90 Galvanized
steel will be used if and where 12 gauge is specified.
Facts on Galvalume Plus:
• Oil-free product (resists finger printing and smudging associated with
standard Galvalume)
• Excellent resistance to storage stain. Easier to handle and store than
regular Galvalume and galvanized.
• Provides incredible resistance to heat, which translates to reduced energy
costs for end users. In many cases it will eliminate the need for
insulation.
• Incorporates superior corrosion resistance than that of standard Galvalume
and galvanized.
• Maintains its new look longer than standard Galvalume and galvanized. Has
excellent resistance to weathering.
The Galvalume Plus coating, which is applied by the continuous hot-dip
process, is an alloy consisting of approximately 55% aluminum, 43.4% zinc and
1. 6% silicon by weight. Exposure tests performed by Bethlehem Steel showed
Galvalume Plus proved to outlast galvanized by four times in severe marine
environments. It also outlasted standard Galvalume in all cases.
High Temperature Quality:
Galvalume Plus Sheet is used in applications where the base metal may become
embrittled due to continuous or intermittent exposure over a pro-longed
period of time to intermediate temperatures 315'C to 482'C (600 to 900'F) .
This High Temperature Quality provides excellent resistance to heat oxidation
at these temperatures. This quality is produced with Heavy Commercial Grade
50 (AZ180) coating.
Heat Reflective and Solar Reflectance
Bare, unpainted Galvalume Plus product has undergone extensive testing, to
determine its solar reflective performance. Test results qualified Galvalume
Plus coated steel as an approved roof product by ENERGY STAR Program for both
low-slope and high-slope applications. On newly manufactured Galvalume Plus,
heat reflectivity was also rated above the minimum EPA requirement of 0. 65.
Page 728 of 735
Agenda Item #21.
(SteelMaster
S R.r Iq 11V dK)
www.SteelMasterUSA.com
For weathered roofs over three years of age, the solar reflectance also
exceeds the minimum EPA requirement of .50 for maintenance.
Arch and End Wall Panels:
All SteelMaster arch panels are precision cold formed and will be within
manufacturing and design tolerances. Each arch panel has a 7 .5" depth
corrugation, which provides superior strength varying with the gauge of the
steel utilized. All SteelMaster panels are pre-cut, die-punched and designed
to overlap and align with each adjacent panel. This translates to fast,
simple and economical construction time. Bolt holes are punched 6-15/16%"
apart down each seam with a double row of holes at 9" overlap at every
connection. The cross corrugations are alleviated at the overlap to create a
weather tight seal. The triple flat seam overlap arch section to arch
section has a 1" overlap on each of the three faces. The strong efficient
SteelMaster arch system design provides a superb structural skin unparalleled
in the industry.
All end wall and door panels are 18" (24") * wide (center-to-center on the
bolt holes) in, at a minimum, 22 gauge steel. Every panel is pre-cut and die-
punched for ease of assembly. All end walls are corrugated to 3 lam" (7.5")*.
End wall panels are designed according to the door system employed whether
roll-up, sliding, swing or accordion styles and will accommodate any opening
size, provided that it fits within the building. All steel end walls include
inner and outer curved flashing angles, to connect end panels to the arch
systems.
Hardware:
All arch and end wall panel fasteners are 5/16" - 18 threads/inch Grade 2
minimum SAE corrosive resisting machine bolts and locking nuts, with
polyethylene pre-assembled sealing washers tested to ASTM D638 tensile
strength specifications. The fasteners to attach the building to the base
connection are 3/8" diameter with Grade 8A minimum SAE corrosive resisting
machine bolts and locking nuts, with polyethylene pre-assembled sealing
washers tested to ASTM D638 tensile strength specifications.
NZF3000 corrosion protection provides in excess of 2000 hours salt spray life
(direct salt spray testing until red rust) . Other non-structural fasteners,
such as tek screws, shall be of standard commercial quality as required.
***DT1500 will be used on carport systems and JS1000 on buildings requiring
12 ga and 14 gauge materials.
Flashing Angle & Foam Gasket*:
Specially fabricated curved flashing angles are utilized at all end wall to
roof transitions to provide a finished edge on the last arch panel and seal
the end wall to the arches. These curved angles are custom made to the radius
of the building and provide connection for standard or custom end walls.
SteelMaster includes a polyurethane open cell foam weather-strip gasket to
cushion the end wall inside the curved angles. The foam compresses to create
a cushioned seal at each arch panel.
Personnel Doors*:
Page 729 of 735
Agenda Item #21.
rt o I ter
sprIi 0 V L0 ass
www.SteelMasterUSA.com
Pre-hung service doors are standard and are designed to pre-align with the
end wall or side wall panels. All fastener holes are pre-punched and aligned
for modular insertion. Doorframes are fabricated from minimum 16-gauge steel
with a conventional flush panel 18 gauge steel door to accommodate a
commercial grade handset and can be insulated or non-insulated.
Skylights*:
These panels will take the place of an existing steel roof panel (specific
locations vary per model) . These panels are manufactured to match the
corrugation and, where applicable, curvature of the roof panel that they
replace. This insures a complete watertight connection. Panels are made with
pigmented ultra-violet inhibitors, which are added to our resin to reduce
discoloration. Various weights are available from 12oz. to 24oz. When used,
skylights are recommended at a maximum of one every 20 linear feet of
building.
*Optional
Page 730 of 735
Agenda Item #21.
Toll Free : 800-241-8339 n.19� ® Sales Fax : 770-662-5053
In Georgia : 770-447-1928 AKERS BUILDING SYSTEMS,INC Customer Service Fax: 770-368-1969
3300 Holcomb Bridge Rd., Suite 201
Peachtree Corners, GA 30092
Quote RefNo : Q161631 Quote Date : 09-30-2025 Good Thru : 10-07-2025
Purchaser: DOUG CHAMBERS Primary Contact : DOUG CHAMBERS
Address : TBD City : TEQUESTA
County : PALM BEACH Phone : (561) 768-0483 Email : DCHAMBERS@TEUQESTA.ORG
State : FL Cell : Sales Rep : BAILEY MCBRIDE
Zip : 33469 Fax : Building : 1 OF 1
Ship To : TBD County : PALM BEACH
City : TEQUESTA State : FL Zip : 33469
CUSTOMER IS HEREBY PRESENTED A PROPOSED CONTRACT FOR THE STEEL BUILDING BELOW:
Width : 40' Length : 80, Eave Height : 14'
Building Profile : GABLE Roof Pitch : 4:12
Bay Spacing : 4@20' Column Type : STANDARD Girt Condition ; STANDARD
Roof Type : 26 GA PBR Roof Sheet Gauge : 26 Wall Sheet Gauge : 26
Code : FBC 2023 Wind Load : 170 EX C Snow Load : 5
Collateral Load : 1# ROOF Live Load : 20 Reducible : YES
Rake & Eave Trim
Roof Color : CHOICE Wall Color: CHOICE Color : CHOICE
Framed Opening Gutters& Down
Trim Color: CHOICE Corner Trim Color: CHOICE Spouts Color : CHOICE
Special Specifications :
Anchor Bolt Drawings, Stamped Certified Drawings : State of FL
PURCHASER MUST VERIFY BUILDING CODES, LOADS, ENERGY CODES,AND SALES TAX%WITH LOCAL AUTHORITY. Sign Page 731 Of 7.35
[Page 1]
Agenda Item #21.
Toll Free : 800-241-8339 (��e Sales Fax : 770-662-5053
In Georgia : 770-447-1928 AKERS BUILDING SYSTEMS,INC Customer Service Fax: 770-368-1969
3300 Holcomb Bridge Rd., Suite 201
Peachtree Corners, GA 30092
ACCESSORIES FOR BUILDING
Quote RefNo : Q161631 Purchaser : DOUG CHAMBERS BASE PRICE : INCL
I
QUANTITY DESCRIPTIOND•
3 FRAMED OPENINGS FULL COVER TRIM 10' X 10' INCL
1 FRAMED OPENINGS FULL COVER TRIM 12' X 14' INCL
1 FRAMED OPENINGS SEE OTHER 3'-4" X 7'-2" INCL
1 FRAMED OPENINGS SEE OTHER 30'' X 30" INCL
EAVE CONDITION GUTTER AND DOWNSPOUTS INCL
BASE CONDITION BASE ANGLE W/TRIM INCL
FASTENERS LONG LIFE INCL
OTHER ITEM : BUILDING SHIPPING TO TEQUESTA, FL. INCL
OTHER ITEM : STANDARD RED-OXIDE PRIMARY AND SECONDARY FRAMING. INCL
OTHER ITEM : STANDARD GIRT AND PURLIN SPACING PER ARCO DESIGN. INCL
OTHER ITEM : 1' OVERHANG INCLUDED AT FULL ROOF PERIMETER (WITH 26-GAUGE PBR
SOFFIT). INCL
OTHER ITEM : WAINSCOT WITH TRIM UP TO 4' AT ALL WALLS. INCL
BUILDING &ACCESSORIES SUBTOTAL $65,184.44
OTHER : 6% SALES TAX $3,911.07
OTHER : $50 FL TAX DISTRIBUTION FEE $50.00
TOTAL : $69,145.51
ANCHOR BOLTS NOT INCLUDED. I STAMPED FOUNDATION DRAWINGS NOT INCLUDED. ADD $650
PLUS TAX. I ADD $5,580 PLUS TAX FOR 3" R-10 BATT INSULATION IN ROOF AND WALLS. I ROLL UP
DOORS, WALK DOOR, AND WINDOW TO BE PROVIDED BY OTHERS. I ANYTHING NOT MENTIONED,
Additional information : NOT INCLUDED.
30% of Contract Price Due Upon Balance due in Cashiers Check Prior to
Acceptance : $20,743.65 Unloading : $48,401.86
PURCHASER MUST VERIFY BUILDING CODES, LOADS, ENERGY CODES,AND SALES TAX%WITH LOCAL AUTHORITY. Sign : Page 732 of 735
[Page 2]
Agenda Item #21.
Toll Free : 800-241-8339 n.19� ® Sales Fax : 770-662-5053
In Georgia : 770-447-1928 AKERS BUILDING SYSTEMS,INC Customer Service Fax: 770-368-1969
3300 Holcomb Bridge Rd., Suite 201
Peachtree Corners, GA 30092
Quote RefNo : Q161631 Purchaser : DOUG CHAMBERS
Estimated Delivery : Weeks
Accepted by Purchaser this day of 2025 FOR OFFICE USE ONLY
Print Name : X
X Approved and Accepted by AKERS BUILDING
SYSTEMS,INC
TOTAL MATERIAL PRICE : $69,145.51
Title
LABOR IS NOT INCLUDED IN TOTAL MATERIAL PRICE:
LABOR BY OTHERS day of 2025
PURCHASER MUST VERIFY BUILDING CODES, LOADS, ENERGY CODES,AND SALES TAX%WITH LOCAL AUTHORITY. Sign Page 7.3.3 Of 7.35
[Page 3]
Agenda Item #21.
IS
Page 734 of 735
e r
Nm Wiilen3nCe
-� hildiq
00l }
-
� +sue
F •
f.
I` •ef
Remove Multiple StrujuiEs
p ..
A"i
g 1• `'
Sp
9 _ y r •A 91,
;• T