Loading...
HomeMy WebLinkAboutDocumentation_Regular_Tab 21_10/9/2025 Agenda Item #21. Regular Council STAFF MEMO x Meeting: Regular Council - Oct 09 2025 Staff Contact: Doug Chambers, Director of Public Department: Public Works Works Consider The Replacement of Outdated Parks and Recreation Structures at Tequesta Park . - Project Background The Parks and Recreation Department proposes the construction of a new Operations and Storage Facility at Tequesta Park to replace three existing, aged wooden structures. These structures—used for staff operations, equipment storage, and seasonal materials—are over 50 years old, deteriorating rapidly, and no longer compliant with current building or safety codes. They are unfit for staff occupancy and incapable of securing valuable assets from theft, weather, or hurricane damage. Purpose of the New Facility The proposed facility will serve as a centralized, code-compliant structure to: • Store specialized landscaping and field maintenance equipment (e.g., zero-turn mowers, reel mowers) • House event and recreation program equipment and supplies • Provide secure storage for seasonal decorations and field tools • Support staff with a small office and operational space • Improve protection for Village assets and ensure safer, more efficient working conditions The building will be engineered to withstand 180 mph winds, fully complying with Florida Building Code wind-load requirements. It will sit on a newly constructed concrete slab foundation. Proposal Review Three quotes were obtained from qualified vendors. Below is a comparison of key details: 1. Eversafe Buildings — Recommended Vendor • Building Size: 40' x 80' x 14' • Price (after discount): $53,078.00 • Includes: o Free delivery and installation o Two 12' x 14' and two 10' x 10' roll-up doors (with chain hoists) o Walk doors and windows o Concrete anchors o Engineered stamped drawings 0 40-year panel warranty, 20-year rust-through frame warranty, 12-month workmanship warranty o Free installation on owner's pad • Notes: Best value based on price, comprehensive warranty, and inclusion of installation Page 717 of 735 Agenda Item #21. Arco Building Systems • Building Size: 40' x 80' x 14' • Total Material Price: $69,145.51 • Does NOT include: o Installation o Anchor bolts o Foundation or concrete work • Extras: o $650 additional for stamped foundation drawings o $5,580+ for roof/wall insulation (not included) o Roll-up doors and windows must be supplied by others • Warranty: Not clearly defined in the proposal SteelMaster Buildings • Building Size: 39'10" x 60'5" x 15'9" • Price: $51,000 base for 60' length; $63,000 for 80' length • Does NOT include: o Installation o Concrete or slab o Roll-up garage doors • Includes: 0 40-year mill-backed warranty o Delivery and stamped engineered drawings • Notes: Limited in scope and size compared to the others; significant elements excluded Replacing the existing structures with a professionally installed, hurricane-rated steel facility will greatly enhance the efficiency, safety, and security of Parks and Recreation operations. This document and any attachments may be reproduced upon request in an alternative format by completing our Accessibility Feedback Form, sending an e-mail to the Village Clerk or calling 561- 768-0443. BUDGET AMOUNT $250,000 AMOUNT AVAILABLE EXPENDITURE AMOUNT: $250,000 $45,073.80 FUNDING SOURCES: 303-323-663.672 IS THIS A PIGGYBACK: ❑ Yes ❑x N/A DID YOU OBTAIN 3 QUOTES? ❑ Yes ❑x N/A QUOTE 1 - BUSINESS NAME Eversafe QUOTE AMOUNT $45,073.80 QUOTE 2 - BUSINESS NAME Steel Master QUOTE AMOUNT$51,000.00 QUOTE 3 - BUSINESS NAME Arco Building QUOTE AMOUNT $69,145.51 Systems Page 718 of 735 Agenda Item #21. COMMENTS/EXPLANATION ON SELECTIONStaff recommends awarding the contract to Eversafe Buildings based on overall best value, as their proposal includes installation, stamped engineering drawings, and industry-leading warranties—all at the lowest cost—while other proposals exclude installation and key components. Staff recommends approval of the Eversafe proposal and to proceed with planning, permitting, and implementation. Eversafe Buildings Quote (40x80x14) R5 Color Chart PICTURE OF MAINTENANCE FACILITY STEEL MASTER TEQUESTA PARK MAINT FACILITY ARCO BUILDING 40x80 Quote 9.30.25 Teguesta Park Maintance Building Locations Page 719 of 735 �� �TEEL BUILDING PROPOSAL A+ A^0; � 2RSAFE BUILDINGS 1 11175 CICERO DR STE 135 1 ALPHARETTA,GA 30022 BBB BUILTSAFE BUILTSTRONG BUILTTOLAST PH:1-800-374-7106 1 FAX:1-800-374-4694 1 WWW.EVERSAFEBUILDINGS.COM A Longlif,Steel Buildings company CUSTOMER: QUANTITY DESCRIPTION Doug Chambers BUILDING DETAILS DATE_: 40'x 80'x 14'Large Span Building 10/2/2025 2 Full Sides With Upgraded Vertical Sheeting&Wainscot Finish(Includes Hat Channels) 1 Full End With Upgraded Vertical Sheeting&Wainscot Finish(Includes Hat Channels) ADDRESS: 1 Full End With Upgraded Vertical Sheeting&Wainscot Finish(Includes Hat Channels) TBD Upgraded Vertical Roof With 6"Overhang(Vertical Roof Includes Hat Channels&Ridge Cap) CITY/STATE: Jupiter,FL Heavy Duty 26 Gauge Roof And Wall Sheeting ZIP: 33469 COUNTY: Palm Beach PHONE (561)769-0483 E-MAIL: dchambers@tequesta.org BUILDING TYPE: ACCESSORIES Large Span Building 1 12'x 14'High Impact Heavy Duty Lockable Roll Up Door w/45 Degree Angle Cuts(With Chain Hoist) ROOF SIZE: 2 10'x 10'High Impact Heavy Duty Lockable Roll Up Door w/45 Degree Angle Cuts(With Chain Hoist) 40'x 81' 1 10'x 10'High Impact Heavy Duty Lockable Roll Up Door w/45 Degree Angle Cuts(With Chain Hoist) BUILDING SIZE: 40'x 80' 1 Roll Up Door Side Frame WALL HEIGHT: 4 Seals for Roll Up Door(Top&Sides) 14' ROOF PITCH: 2/12 ROOF TYPE: 1 Heavy Duty Walk Door With Keyed Lock-36"x 80"High Impact(Solid) (Installed on side of building) Upgraded Vertical Roof With 6" 1 30"x 30"High Impact Single Hung Window Overhang 1 Window Side Frame FRAME TYPE: Heavy Duty 14 Gauge Galvanized Large Span Steel Truss Frame With Double Legs FRAME SPACING: 4'On Center Concrete Anchors SHEETING TYPE: Upgraded Heavy Duty 26 Gauge Galvanized Steel CERTIFICATION: Risk Cat 2 Commercial ADDITIONAL NOTES: Foam Enclosures-Ridge and Eaves MISCELLANEOUS *Buyer must have a Reach Lift with a 42'reach and 6,00011b pound capacity on site for installers during the Certified Building installation process.Any rental or use fees incurred are As Built Stamped Drawings(2 Sets) Buyer's responsibility.(Est.$1,200-1,500/week rental fee(.Rental can be arranged. FREE DELIVERY TO JOBSITE FREE INSTALLATION ON YOUR PAD NOTE:BUILDING WILL BE CERTIFIED FOR UP TO 170MPH AND COMPONENTS MUSTBE HIGH IMPACT. FREE COLOR MATCH FASTENERS ***40 YEAR LIMITED WARRANTY ON PANELS*** ***20 YEAR LIMITED RUST THROUGH WARRANTY ON FRAME AND ROOF*** ***12 MONTH WORKMANSHIP WARRANTY ON BUILDING*** Note:Discount Good Until: Building Price $65,785.00 *Buyer must provide a tax exemption Monday,October 20th,2025 20%Discount -$13,157.00 certificate to be eligible for tax exemption. ***We can arrange to have your building permits pulled(building&concrete or i*** Additional Labor $400.00 Payment requirements: BUILDING PRICE(AFTER DISCOUNT) $53,028.00 $8,704.20 due now *Sales Tax(0.00%) $0.00 Drawings(Commercial) $750.00 $22,536.90 due at scheduling of installation Total $53,778.00 $22,536.90 due immediately following installation Due Now** $8,704.20 PREPARED BY: 'Permit fees are not included BALANCE(See Payment Breakdown) $45,073.80 William French *Eversafe has the right to correct any content or pricing errors on this quote Page 720 of 735 Agenda Ite # EVEMAFE BUILT SAFE BUILT STRONG BUILT TO LAST BRITE WHITE IVORY LIGHT STONE SAHARA TAN E LIGHT GRAY CLAY HAWAIIAN BLUE BRIGHT RED BARN RED BURGUNDY IVY GREEN BLACK • BURNISHED SLATE COCOA BROWN CHARCOAL GALVALUME 1-800-374-7106 www.eversafebuildings.com • AMERICAN MADE-AMERICAN PROUD *Colors shown represent finish colors as accurately as possible.However,colors may vary slightly on actual building.Digitial depictions of colors may appear different depending on the device used to view them.Similarly,print quality can change the appearance of printed depictions.If color choice is critical,please request a metal color sample.Eversafe is not responsible for such variations in color. • • • 0 2025 Eversafe Buildings Agenda Item #21. { 4b .r � I ryl � u 3 f ' Lj Page 722 of 735 Agenda Item #21. �SteelMaster S R.r Iq[ILI!LDINC, www.Steel MasterUSA.com Building Proposal 1023 Laskin Road,Suite 109 Virginia Beach,VA 23451 1-800-341-7007telephone 1-757-422-9167fax Prepared For: Doug Chambers Village of Tequesta Jupiter FL 33469 Tel #: 561-768-0483 Email: dhaambers@tequesta.org Prepared By: Christin Day, Project Specialist Date: 10/l/25 Division: Commercial/Industrial Division Quote firm until: 10/31/25 Building S Model Price (not incl FL tax) 540-16-60 Approx Weight: 14, 000 lbs. $51, 000.00 ----------------------------------------------------------------------------- Dimensions: 39'-10 . 625" wide x 15'-9. 625" high x 60'-5" long All Building Materials Include: • Arches: (30) Grade 80 heavy duty Heavy gauge silver steel arches, AZM 180/AZ 60 Galvalume Plus coating, double bolt 9" lap seams. • Front End Wall: Solid end wall with (1) framed opening, measuring 10'w x 10'h. Includes header beam, canister door support posts, and end wall trim. • Rear End Wall: Solid end wall with (Qty.l) outer angle trim flange. • Service Door: (1) 30 .5"w x 79.5"h Conventional Door with lockset. • Industrial Base Connector: Industrial 14 gauge Galvalume Plus base plate • Premium Grade Hardware: 5/16" Grade 2 preassembled fasteners with polyethylene washers to secure the building components through predrilled holes. • Exclusion: Anchor Bolts, garage door, construction/assembly. • Drawings: (Qty.3) Complete Sets of Engineer Stamped Shop Drawings. • Warranty: 40-year non-pro-rated mill-backed warranty. • Delivery: Included to jobsite location in Jupiter, FL. • Optional Add On: To change the length to 80'1 you are looking at $63,000 delivered before taxes. Terms & Delivery Schedule Payment Terms 25% deposit required with order placement. Balance to be paid on delivery. Shipping Please allow six to eight weeks for delivery of materials. Materials will be delivered via flat bed truck. Customer is responsible for unloading of truck. Page 723 of 735 Agenda Item #21. (Steel s nc:i�otad�v�^a�s www.SteelMasterUSA.com Arch Design Specifications (IBC15- Cat I) Ground Snow Load: Palm Beach CO, FL (0 PSF) Wind Load: Palm Beach CO, FL (153 MPH) Live Load: Palm Beach County, FL (0 PSF) SteelMaster Terms and Conditions This order is subject to price increases if delivery of the building is more than 60 days after order date. 1. DEPOSIT --The deposit shall be held by the seller as security for the completion of Buyer's duties under this contract. The deposit shall not be refunded to the buyer except in the event of a material breach by Seller of this contract. In the event of a material breach of the contract by Buyer, Seller, at Seller' s option, shall have the right to (1) retain the deposit as liquidated damages or, (2) retain the deposit and pursue all other rights and remedies shall be cumulative and not exclusive of any other such right or remedy. 2. PAYMENT -- Payment of the total purchase price, less the amount of the deposit, is to be paid COD upon delivery of goods to the buyer. Buyer hereby grants to the seller a security interest in the structure to secure payment as set forth in this contract. 3. SHIPMENT -- This is not a delivery contract unless otherwise specified and regardless, delivery is not guaranteed to the location specified but rather delivery will be as close to said address as reasonable in the sole discretion of the freight carrier. Seller shall not be responsible for the delivery of goods at any place other than the manufacturer's place of business. Buyer, upon being notified that the goods are ready for shipment shall receive and accept delivery of goods within 14 days of such notification. If buyer fails to accept delivery of the goods within two months from the expiration of said 14-day period Seller may at its option and without notice treat this agreement as being materially breached in which event seller shall have all remedies provided by law for breach of contract. If Buyer picks up goods at Seller's factory or if Buyer elects to use a carrier of Buyer' s choosing, Seller shall not be responsible for loss or damage of goods in transit. 4. WARRANTIES -- Seller warrants that its goods are as described in the quote document previously provided and are free from any defects in material or workmanship. SELLER MAKES NO OTHER WARRANTEE, EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE ABOVE OBLIGATION ARE HEREBY DISCLAIMED. ANY RUST PERFORATION WARRANTY WHICH BUYER MAY RECEIVE IS GIVEN DIRECTLY BY THE MANUFACTURER TO BUYER AND IS NOT GIVEN BY THE SELLER. 5. SELLER'S LIABILITY -- In the event of any breach of seller's warranties and in full satisfaction of all incidental damages, Seller, at its option, will either replace the defective or nonconforming goods or refund the purchase price for such defective or nonconforming goods, upon the return thereof to seller. Seller will not be liable for consequential damages and under no circumstances shall its liability exceed the purchase price for defective or nonconforming goods. Seller shall have no responsibility or Page 724 of 735 Agenda Item #21. r mu'* IR.CH 0 V L0 ass www.SteelMasterUSA.com liability whatsoever for the erection of the structure or structures which are the subject of this agreement or for the selection of a contractor to erect the structure or structures. Seller is in no way responsible for damage that may result to a buried building unless the building has specifically been designed for this purpose as clearly indicated in this agreement. It is specifically agreed that the foregoing remedies are exclusive and in substitution for all other remedies to which the buyer would otherwise be entitled. Seller shall be given a reasonable opportunity to investigate all claims or complaints and no goods may be returned to seller without the written approval of seller. Any claim will be conclusively deemed waived unless written notice thereof is given to the seller within thirty (30) days following the receipt of the goods. 6. SOIL CONDITION & FOUNDATION -- It is the sole responsibility of the buyer to assure that soil and subsoil conditions at the site location are of sufficient density to support and sustain pressures and forces exerted thereon by the foundation, the building purchased, and the type and quantity of the material stored therein. The buyer of the building to be constructed is responsible for following and complying with the specifications and instructions contained in the manual supplied to buyer. 7. RISK OF LOSS -- Seller shall not be responsible for loss or damage to goods in transit or during erection or construction. In case of loss or damage, claims must be made against the carrier or erection contractor by the buyer. 8. VENUE -- This contract shall be governed by and construed in accordance with the laws of the Commonwealth of Virginia. Buyer agrees that any suit or action arising out of or relating to this contract shall be instituted exclusively in the Courts of the City of Virginia Beach, Virginia. Buyer hereby waives any objection it may have to the laying of venue in such court. 9. FORCE MAJEURE -- Failure of Seller to make, or Buyer to take, all or any part of any shipment hereunder, if such failure is due to acts of God, war, labor difficulties, breakdown or damage to Seller's plant facilities or Buyer's receiving facilities, embargoes, shortages of raw materials or transportation equipment, compliance with any law, regulation or order of any public authority and any cause beyond either party's control shall not subject party to any liability to the other party. 10.NOTICES -- All written communications or required notices between SteelMaster and the Buyer shall be sent by first class mail, postage prepaid, or by nationally recognized overnight delivery to the address, or to the facsimile listed below: Communications shall be signed and sent: If to SteelMaster: SteelMaster Buildings, LLC 1023 Laskin Road, Suite 109 Virginia Beach, VA 23451 757-422-6800 telephone 757-422-9167 facsimile If to Buyer: (Insert Applicable name) Page 725 of 735 Agenda Item #21. (Steel s nc:i�otad�v�^a�s www.SteelMasterUSA.com SteelMaster Buildings® Technical Specifications Re: Clear Span Arch Type Steel Structure General Requirements: Scope. This specification covers the design, material, manufacture, as well as shipping and handling of clear span arch type steel structure. Depending upon specific model, each arch section will be 24" center to center of fastening holes once constructed. The interior of the structure below the steel arch shall be clear and free of any structural members and shall provide unobstructed floor space. The structure shall also include all accessories and items required and necessary for the scope and stated use and as herein specified. Dimensions: The structure shall have the following approximate minimum exterior dimensions: Overall Width: 39'-11" Overall Length: 60'-5" Peak Height: 15'-9" Operation and Use: The structure provided by SteelMaster BuildingsO shall be designed to provide a minimum 30-year operational use period in normal conditions. The structure shall be capable of being assembled, operated and dismantled in all ambient temperatures between -20 F and 120 F. Design Criteria: Building design shall comply with the structural requirements of the latest adopted version of the International Building Code (IBC) . Designs conform also to "Minimum Design Loads for Buildings and Other Structures" published by the American Society of Civil Engineers (ASCE 7) and the "Specification for Design of Cold-Formed Steel Structure Members" published by the American Iron and Steel Institute (AISI) . Since SteelMaster arch panels contain numerous stamped transverse stiffeners, AISI requires that the design strength of SteelMaster arch panels shall be confirmed by test results. All structures structural design calculations and foundation designs are in accordance with recognized code standards using methodology from ASCE 7 . The structure shall comply with current issues of AISC, AISI, NEMA, and ASTM specifications, as design loads given. Appropriate safety factors must be maintained. Wind load factors and coefficients used in design of the arches must be in accordance with ASCE 7 . Page 726 of 735 Agenda Item #21. rt o I ter IR.CH 0 V L0 ass www.SteelMasterUSA.com All design certifications are signed and sealed by a registered Professional Engineer. Also, reaction diagrams for independent foundations designs can be provided when it is specified at time of purchase that a custom foundation will be implemented. A total of 13 basic load cases and 55 load combinations shall be used to design SteelMaster Buildings. Wind Loads: The arches shall be designed to be capable of withstanding 3-second gust wind loads from any direction. The structure shall be designed using an exposure category "C" for determining design wind pressure on the arches. The methodology is to be taken from ASCE 7 . Exposure C is defined as open terrain with scattered obstructions having heights generally less than 30 ft. This category includes flat open country and grasslands. Ground Snow Loads: The SteelMaster structure shall be designed to meet or exceed all local snow load requirements. Unless otherwise specified, the building shall be designed for Importance Category 1 usage. The distribution of loading shall be in accordance with the International Building Code and applicable design standards. Live Loads: At a minimum, the SteelMaster structure shall be capable of supporting a roof live load of twenty pounds per square foot projected over the entire structure and any probable arrangements of loading resulting in the highest stress in the members. As defined by IBC, live loads are those loads produced by the use and occupancy of the building and do not include dead load, construction load, or environmental loads such as wind load, snow load, rain load, earthquake loads or flood loads. ASCE 7 further clarifies that live loads on a roof are those produced (1) during maintenance by workers, equipment, and materials; and (2) during the life of the structure by movable objects such as planters and by people. Seismic Loads: Seismic loads and designs shall be based on the requirements of the International Building Code & ASCE 7 . Foundation Design: SteelMaster will provide foundation design details to the purchaser to meet the structural requirements and accord with the boundary conditions of the building. Where a custom foundation design is to be implemented, SteelMaster will revise the arch designs and provide the arch reactions required for the foundation design. Materials Specifications: Page 727 of 735 Agenda Item #21. KON SteeflMaster sprIi 0 V dam s www.SteelMasterUSA.com All materials used in SteelMaster structures shall be new, without defects, and free of repairs. The quality used in the structure shall be such that the structure is in conformance to the performance requirements specified herein. Metals: All metal components of the structure including, but not limited to, the arch panels, end wall panels, specialty foundation base connectors, and other framing materials are fabricated from Heavy Commercial AZ 180 g/mz minimum triple spot Galvalume Plus coating, in accordance with ASTM A 792 & A792M Grade 50 minimum with a 50 ksi minimum yield, and 65 ksi minimum tensile strength. Coating: Galvalume Plus has a clear, organic resin coating, which is applied to both sides. Once applied the coating is then thermally cured. Galvalume Plus provides a bright, attractive appearance with a fine spangle and gentle sheen. Galvalume Plus steel will be used for gauges 22-11 and G90 Galvanized steel will be used if and where 12 gauge is specified. Facts on Galvalume Plus: • Oil-free product (resists finger printing and smudging associated with standard Galvalume) • Excellent resistance to storage stain. Easier to handle and store than regular Galvalume and galvanized. • Provides incredible resistance to heat, which translates to reduced energy costs for end users. In many cases it will eliminate the need for insulation. • Incorporates superior corrosion resistance than that of standard Galvalume and galvanized. • Maintains its new look longer than standard Galvalume and galvanized. Has excellent resistance to weathering. The Galvalume Plus coating, which is applied by the continuous hot-dip process, is an alloy consisting of approximately 55% aluminum, 43.4% zinc and 1. 6% silicon by weight. Exposure tests performed by Bethlehem Steel showed Galvalume Plus proved to outlast galvanized by four times in severe marine environments. It also outlasted standard Galvalume in all cases. High Temperature Quality: Galvalume Plus Sheet is used in applications where the base metal may become embrittled due to continuous or intermittent exposure over a pro-longed period of time to intermediate temperatures 315'C to 482'C (600 to 900'F) . This High Temperature Quality provides excellent resistance to heat oxidation at these temperatures. This quality is produced with Heavy Commercial Grade 50 (AZ180) coating. Heat Reflective and Solar Reflectance Bare, unpainted Galvalume Plus product has undergone extensive testing, to determine its solar reflective performance. Test results qualified Galvalume Plus coated steel as an approved roof product by ENERGY STAR Program for both low-slope and high-slope applications. On newly manufactured Galvalume Plus, heat reflectivity was also rated above the minimum EPA requirement of 0. 65. Page 728 of 735 Agenda Item #21. (SteelMaster S R.r Iq 11V dK) www.SteelMasterUSA.com For weathered roofs over three years of age, the solar reflectance also exceeds the minimum EPA requirement of .50 for maintenance. Arch and End Wall Panels: All SteelMaster arch panels are precision cold formed and will be within manufacturing and design tolerances. Each arch panel has a 7 .5" depth corrugation, which provides superior strength varying with the gauge of the steel utilized. All SteelMaster panels are pre-cut, die-punched and designed to overlap and align with each adjacent panel. This translates to fast, simple and economical construction time. Bolt holes are punched 6-15/16%" apart down each seam with a double row of holes at 9" overlap at every connection. The cross corrugations are alleviated at the overlap to create a weather tight seal. The triple flat seam overlap arch section to arch section has a 1" overlap on each of the three faces. The strong efficient SteelMaster arch system design provides a superb structural skin unparalleled in the industry. All end wall and door panels are 18" (24") * wide (center-to-center on the bolt holes) in, at a minimum, 22 gauge steel. Every panel is pre-cut and die- punched for ease of assembly. All end walls are corrugated to 3 lam" (7.5")*. End wall panels are designed according to the door system employed whether roll-up, sliding, swing or accordion styles and will accommodate any opening size, provided that it fits within the building. All steel end walls include inner and outer curved flashing angles, to connect end panels to the arch systems. Hardware: All arch and end wall panel fasteners are 5/16" - 18 threads/inch Grade 2 minimum SAE corrosive resisting machine bolts and locking nuts, with polyethylene pre-assembled sealing washers tested to ASTM D638 tensile strength specifications. The fasteners to attach the building to the base connection are 3/8" diameter with Grade 8A minimum SAE corrosive resisting machine bolts and locking nuts, with polyethylene pre-assembled sealing washers tested to ASTM D638 tensile strength specifications. NZF3000 corrosion protection provides in excess of 2000 hours salt spray life (direct salt spray testing until red rust) . Other non-structural fasteners, such as tek screws, shall be of standard commercial quality as required. ***DT1500 will be used on carport systems and JS1000 on buildings requiring 12 ga and 14 gauge materials. Flashing Angle & Foam Gasket*: Specially fabricated curved flashing angles are utilized at all end wall to roof transitions to provide a finished edge on the last arch panel and seal the end wall to the arches. These curved angles are custom made to the radius of the building and provide connection for standard or custom end walls. SteelMaster includes a polyurethane open cell foam weather-strip gasket to cushion the end wall inside the curved angles. The foam compresses to create a cushioned seal at each arch panel. Personnel Doors*: Page 729 of 735 Agenda Item #21. rt o I ter sprIi 0 V L0 ass www.SteelMasterUSA.com Pre-hung service doors are standard and are designed to pre-align with the end wall or side wall panels. All fastener holes are pre-punched and aligned for modular insertion. Doorframes are fabricated from minimum 16-gauge steel with a conventional flush panel 18 gauge steel door to accommodate a commercial grade handset and can be insulated or non-insulated. Skylights*: These panels will take the place of an existing steel roof panel (specific locations vary per model) . These panels are manufactured to match the corrugation and, where applicable, curvature of the roof panel that they replace. This insures a complete watertight connection. Panels are made with pigmented ultra-violet inhibitors, which are added to our resin to reduce discoloration. Various weights are available from 12oz. to 24oz. When used, skylights are recommended at a maximum of one every 20 linear feet of building. *Optional Page 730 of 735 Agenda Item #21. Toll Free : 800-241-8339 n.19� ® Sales Fax : 770-662-5053 In Georgia : 770-447-1928 AKERS BUILDING SYSTEMS,INC Customer Service Fax: 770-368-1969 3300 Holcomb Bridge Rd., Suite 201 Peachtree Corners, GA 30092 Quote RefNo : Q161631 Quote Date : 09-30-2025 Good Thru : 10-07-2025 Purchaser: DOUG CHAMBERS Primary Contact : DOUG CHAMBERS Address : TBD City : TEQUESTA County : PALM BEACH Phone : (561) 768-0483 Email : DCHAMBERS@TEUQESTA.ORG State : FL Cell : Sales Rep : BAILEY MCBRIDE Zip : 33469 Fax : Building : 1 OF 1 Ship To : TBD County : PALM BEACH City : TEQUESTA State : FL Zip : 33469 CUSTOMER IS HEREBY PRESENTED A PROPOSED CONTRACT FOR THE STEEL BUILDING BELOW: Width : 40' Length : 80, Eave Height : 14' Building Profile : GABLE Roof Pitch : 4:12 Bay Spacing : 4@20' Column Type : STANDARD Girt Condition ; STANDARD Roof Type : 26 GA PBR Roof Sheet Gauge : 26 Wall Sheet Gauge : 26 Code : FBC 2023 Wind Load : 170 EX C Snow Load : 5 Collateral Load : 1# ROOF Live Load : 20 Reducible : YES Rake & Eave Trim Roof Color : CHOICE Wall Color: CHOICE Color : CHOICE Framed Opening Gutters& Down Trim Color: CHOICE Corner Trim Color: CHOICE Spouts Color : CHOICE Special Specifications : Anchor Bolt Drawings, Stamped Certified Drawings : State of FL PURCHASER MUST VERIFY BUILDING CODES, LOADS, ENERGY CODES,AND SALES TAX%WITH LOCAL AUTHORITY. Sign Page 731 Of 7.35 [Page 1] Agenda Item #21. Toll Free : 800-241-8339 (��e Sales Fax : 770-662-5053 In Georgia : 770-447-1928 AKERS BUILDING SYSTEMS,INC Customer Service Fax: 770-368-1969 3300 Holcomb Bridge Rd., Suite 201 Peachtree Corners, GA 30092 ACCESSORIES FOR BUILDING Quote RefNo : Q161631 Purchaser : DOUG CHAMBERS BASE PRICE : INCL I QUANTITY DESCRIPTIOND• 3 FRAMED OPENINGS FULL COVER TRIM 10' X 10' INCL 1 FRAMED OPENINGS FULL COVER TRIM 12' X 14' INCL 1 FRAMED OPENINGS SEE OTHER 3'-4" X 7'-2" INCL 1 FRAMED OPENINGS SEE OTHER 30'' X 30" INCL EAVE CONDITION GUTTER AND DOWNSPOUTS INCL BASE CONDITION BASE ANGLE W/TRIM INCL FASTENERS LONG LIFE INCL OTHER ITEM : BUILDING SHIPPING TO TEQUESTA, FL. INCL OTHER ITEM : STANDARD RED-OXIDE PRIMARY AND SECONDARY FRAMING. INCL OTHER ITEM : STANDARD GIRT AND PURLIN SPACING PER ARCO DESIGN. INCL OTHER ITEM : 1' OVERHANG INCLUDED AT FULL ROOF PERIMETER (WITH 26-GAUGE PBR SOFFIT). INCL OTHER ITEM : WAINSCOT WITH TRIM UP TO 4' AT ALL WALLS. INCL BUILDING &ACCESSORIES SUBTOTAL $65,184.44 OTHER : 6% SALES TAX $3,911.07 OTHER : $50 FL TAX DISTRIBUTION FEE $50.00 TOTAL : $69,145.51 ANCHOR BOLTS NOT INCLUDED. I STAMPED FOUNDATION DRAWINGS NOT INCLUDED. ADD $650 PLUS TAX. I ADD $5,580 PLUS TAX FOR 3" R-10 BATT INSULATION IN ROOF AND WALLS. I ROLL UP DOORS, WALK DOOR, AND WINDOW TO BE PROVIDED BY OTHERS. I ANYTHING NOT MENTIONED, Additional information : NOT INCLUDED. 30% of Contract Price Due Upon Balance due in Cashiers Check Prior to Acceptance : $20,743.65 Unloading : $48,401.86 PURCHASER MUST VERIFY BUILDING CODES, LOADS, ENERGY CODES,AND SALES TAX%WITH LOCAL AUTHORITY. Sign : Page 732 of 735 [Page 2] Agenda Item #21. Toll Free : 800-241-8339 n.19� ® Sales Fax : 770-662-5053 In Georgia : 770-447-1928 AKERS BUILDING SYSTEMS,INC Customer Service Fax: 770-368-1969 3300 Holcomb Bridge Rd., Suite 201 Peachtree Corners, GA 30092 Quote RefNo : Q161631 Purchaser : DOUG CHAMBERS Estimated Delivery : Weeks Accepted by Purchaser this day of 2025 FOR OFFICE USE ONLY Print Name : X X Approved and Accepted by AKERS BUILDING SYSTEMS,INC TOTAL MATERIAL PRICE : $69,145.51 Title LABOR IS NOT INCLUDED IN TOTAL MATERIAL PRICE: LABOR BY OTHERS day of 2025 PURCHASER MUST VERIFY BUILDING CODES, LOADS, ENERGY CODES,AND SALES TAX%WITH LOCAL AUTHORITY. Sign Page 7.3.3 Of 7.35 [Page 3] Agenda Item #21. IS Page 734 of 735 e r Nm Wiilen3nCe -� hildiq 00l } - � +sue F • f. I` •ef Remove Multiple StrujuiEs p .. A"i g 1• `' Sp 9 _ y r •A 91, ;• T